189 research outputs found
Development and applications of novel strategies for the enhanced mass spectrometric quantification of biogenic amines
Liquid chromatography in combination with triple-quadrupole mass spectrometry (LC-MS/MS) is rapidly developing as the analytical technique of choice for quantitative analysis of small molecules such as steroid hormones, vitamins, and biogenic amines. In recent years, there has been a shift towards widespread adaption of LC-MS/MS in the field of laboratory medicine. One of the compound classes that remains difficult to analyze especially in plasma, are the biogenic amines. Biogenic amines are biologically active compounds containing one or more amine groups and are produced from amino acids. Dopamine, norepinephrine, and epinephrine are synthesized from tyrosine; serotonin from tryptophan, and histamine from histidine. They are regarded as the “classic” biogenic amines, and foremost known for their roles as neurotransmitter. Biogenic amines are important markers for the diagnosis of neuroendocrine neoplasia.Neuroendocrine tumors are rare tumors that originate from cells of the endocrine and nervous system. One common characteristic of neuroendocrine tumors is that they have the ability to take up and metabolize amine precursors. Excessive production of biogenic amines may result in endocrine related complaints. No methods were available that enable the simultaneous profiling of all potentially relevant biogenic amine markers in one profile. We developed new approaches allowing simultaneous detection of these amines, their precursors, and metabolites that are of great interest. They could potentially aid in the diagnosis and management of neuroendocrine tumors.The aim of this thesis was to investigate and develop novel approaches for the enhanced mass spectrometric detection of neuroendocrine biomarkers
Susceptibility to Adrenal Crisis Is Associated With Differences in Cortisol Excretion in Patients With Secondary Adrenal Insufficiency
Objective: To compare cortisol pharmacokinetics and pharmacodynamics mapped through several glucocorticoid sensitive pathways in patients on hydrocortisone substitution with or without an adrenal crisis. Design: A post-hoc analysis of a previously conducted randomized controlled trial in patients with secondary adrenal insufficiency examining the effects of 2 weight-adjusted hydrocortisone doses. Methods: Comparisons were primarily made on a hydrocortisone dose of 0.2-0.3 mg/kg/day for plasma cortisol and cortisone, 24-hour urinary steroid profile, the glucocorticoid sensitive tryptophan-kynurenine pathway, the renin-angiotensin-aldosterone system and aspects of quality of life. Variables of interest were also analyzed on the hydrocortisone dose of 0.4-0.6 mg/kg/day. Results: Out of 52 patients, 9 (17%) experienced at least one adrenal crisis (AC+ group) and 43 did not develop an adrenal crisis (AC- group) during an observation period of 10 years. 24-hour urinary excretion of cortisol and cortisone were lower in the AC+ group (0.05 [IQR 0.03; 0.05] vs. 0.09 [0.05; 0.12] µmol/24h, P=0.01and 0.13 [0.10; 0.23] vs. 0.24 [0.19; 0.38] µmol/24h, P=0.04, respectively). No differences in pharmacokinetics of cortisol were observed. Kynurenine concentrations were higher in the AC+ group (2.64 [2.43; 3.28] vs. 2.23 [1.82; 2.38] µmol/L, P=0.03) as was general fatigue (Z-scores 1.02 [-0.11; 1.42] vs. -0.16 [- 0.80; 0.28], P=0.04). On the higher hydrocortisone dose urinary excretion of cortisol and cortisone was still significantly lower between the AC- and AC + group. The differences in glucocorticoid sensitive variables disappeared. Conclusion: Patients susceptible to an adrenal crisis demonstrated differences in cortisol and cortisone excretion as well as in pharmacodynamics when compared to patients who did not experience an adrenal crisis, suggesting a biological predisposition in certain patients for the development of an adrenal crisis
Pharmacokinetic Modeling of Hydrocortisone by Including Protein Binding to Corticosteroid-Binding Globulin
BACKGROUND: Patients with adrenal insufficiency are treated with oral hydrocortisone (HC) to compensate for the loss of endogenous cortisol production. Intrinsic imperfections of cortisol replacement strategies in mimicking normal cortisol secretion are the underlying cause of the increased morbidity and mortality of patients suffering from secondary adrenal insufficiency (SAI). To improve oral hydrocortisone substitution therapy, a better understanding of its pharmacokinetics (PK) is necessary. The previous PK model did not include protein binding. It is known that protein binding can impact hydrocortisone pharmacokinetics. The aim of this study is to describe HC pharmacokinetics including the protein-binding state using Edsim++ (Mediware, Prague) pharmacokinetic modeling software, paving the way for an in-silico tool suitable for drug delivery design. METHODS: A total of 46 patients with SAI participated in a randomized double-blind crossover study Patients randomly received a low dose of HC (0.2-0.3 mg/kg body weight/day) for 10 weeks, followed by a high dose (0.4-0.6 mg/kg body weight/day) for another 10 weeks, or vice versa. Plasma samples were obtained and analyzed for free and total hydrocortisone. Single compartment population pharmacokinetic analysis was performed using an extended Werumeus-Buning model built in Edsim++. This model includes a mathematical approach for estimating free cortisol by Nguyen et al., taking the protein binding of HC to albumin and hydrocortisone-binding globulin (CBG, transcortin) into consideration, as well as different states of CBG which affect binding kinetics to HC. The goodness of fit for observed versus predicted values was calculated. RESULTS AND CONCLUSIONS: Nguyen's formula for free cortisol estimation was successfully implemented in a pharmacokinetic model. The model shows high Spearman's correlation for observed versus predicted hydrocortisone concentrations. Significantly higher correlations (Spearman's r, 0.901 vs. 0.836) between total and free hydrocortisone AUC24 (area-under the curve over 24 h) are found when comparing new and old models. This new model was used to simulate the plasma concentration-time behavior of a more suitable hydrocortisone formulation
Correction to:An antibody-free LC-MS/MS method for the quantification of intact insulin-like growth factors 1 and 2 in human plasma
Insulin-like growth factors 1 and 2 (IGF-1 and IGF-2) are important biomarkers in research and diagnosis of growth disorders. Quantitative analysis is performed using various ligand-binding assays or enzymatic digestion LC-MS/MS methods, whose widespread adoption is hampered by time-consuming sample preparation procedures. We present a simple and fast antibody-free LC-MS/MS method for the quantification of intact IGF-1 and IGF-2 in human plasma. The method requires 50 mu L of plasma and uses fully N-15-labelled IGF-1 as internal standard. It features trifluoroethanol (TFE)-based IGF/IGF-binding protein complex dissociation and a two-step selective protein precipitation workflow, using 5% acetic acid in 80/20 acetone/acetonitrile (precipitation 1) and ice-cold ethanol (precipitation 2). Detection of intact IGF-1 and IGF-2 is performed by means of a Waters XEVO TQ-S triple quadrupole mass spectrometer in positive electrospray ionisation (ESI+) mode. Lower limits of quantification were 5.9 ng/mL for IGF-1 and 8.4 ng/mL for IGF-2. Intra-assay imprecision was below 4.5% and inter-assay imprecision was below 5.8% for both analytes. An excellent correlation was found between nominal and measured concentrations of the WHO reference standard for IGF-1. Comparison with the IDS-iSYS IGF-1 immunoassay showed good correlation (R-2 > 0.97), although a significant bias was observed with the immunoassay giving substantially higher concentrations. The LC-MS/MS method described here allows for reliable and simultaneous quantification of IGF-1 and IGF-2 in plasma, without the need for enzymatic digestion. The method can be readily implemented in clinical mass spectrometry laboratories and has the potential to be adapted for the analysis of different similarly sized peptide hormones
An antibody-free LC-MS/MS method for the quantification of intact insulin-like growth factors 1 and 2 in human plasma
Insulin-like growth factors 1 and 2 (IGF-1 and IGF-2) are important biomarkers in research and diagnosis of growth disorders. Quantitative analysis is performed using various ligand-binding assays or enzymatic digestion LC-MS/MS methods, whose widespread adoption is hampered by time-consuming sample preparation procedures. We present a simple and fast antibody-free LC-MS/MS method for the quantification of intact IGF-1 and IGF-2 in human plasma. The method requires 50 mu L of plasma and uses fully N-15-labelled IGF-1 as internal standard. It features trifluoroethanol (TFE)-based IGF/IGF-binding protein complex dissociation and a two-step selective protein precipitation workflow, using 5% acetic acid in 80/20 acetone/acetonitrile (precipitation 1) and ice-cold ethanol (precipitation 2). Detection of intact IGF-1 and IGF-2 is performed by means of a Waters XEVO TQ-S triple quadrupole mass spectrometer in positive electrospray ionisation (ESI+) mode. Lower limits of quantification were 5.9 ng/mL for IGF-1 and 8.4 ng/mL for IGF-2. Intra-assay imprecision was below 4.5% and inter-assay imprecision was below 5.8% for both analytes. An excellent correlation was found between nominal and measured concentrations of the WHO reference standard for IGF-1. Comparison with the IDS-iSYS IGF-1 immunoassay showed good correlation (R-2 > 0.97), although a significant bias was observed with the immunoassay giving substantially higher concentrations. The LC-MS/MS method described here allows for reliable and simultaneous quantification of IGF-1 and IGF-2 in plasma, without the need for enzymatic digestion. The method can be readily implemented in clinical mass spectrometry laboratories and has the potential to be adapted for the analysis of different similarly sized peptide hormones
Residual endogenous corticosteroid production in patients with adrenal insufficiency
Objective This study aimed at comparing precursors of endogenous corticosteroid production in patients with primary adrenal insufficiency and in secondary adrenal insufficiency. Design Twenty patients with primary adrenal insufficiency and matched controls and 19 patients with secondary adrenal insufficiency participated in this ancillary analysis of two different studies. Patients and measurements Patients with primary adrenal insufficiency were on stable hydrocortisone and fludrocortisone therapy. Patients with secondary adrenal insufficiency received two different doses of hydrocortisone in a randomized crossover study. Main outcome measures were concentrations of precursors of cortisol and aldosterone measured by LC-MS/MS Results Compared to controls, progressively lower concentrations of the glucocorticoid precursors 11-deoxycortisol, 11-deoxycorticosterone and corticosterone concentrations were found in patients with secondary adrenal insufficiency on lower hydrocortisone dose, secondary adrenal insufficiency on higher hydrocortisone dose and primary adrenal insufficiency, respectively. Half of the primary adrenal insufficient patients showed evidence of residual endogenous cortisol or aldosterone synthesis, as determined by quantifiable 11-deoxycortisol, 11-deoxycorticosterone and corticosterone conce ntrations. In secondary adrenal insufficient patients with higher endogenous cortisol production, as indicated by 11-deoxycortisol concentrations above the median, no increased cortisol exposure was observed both by plasma pharmacokinetic parameters and 24-hour free cortisol excretion in urine. Conclusions Adrenal corticosteroid production is likely to continue during treatment in a considerable percentage of patients with both primary and secondary adrenal insufficiency. In patients with secondary adrenal insufficiency, this synthesis appears to be sensitive to the dose of hydrocortisone. However, the residual corticosteroid concentrations were quantitatively low and its clinical significance remains therefore to be determined
Selective quantification of the 22-kDa isoform of human growth hormone 1 in serum and plasma by immunocapture and LC-MS/MS
The human growth hormone GH1 (22 kDa) is a commonly measured biomarker for diagnosis and during treatment of growth disorders, but its quantification by ligand binding assays may be compromised by the occurrence of a number of isoforms. These can interfere in the assays and lead to differences in results between laboratories and potentially even in the treatment of patients. We present an LC-MS/MS method that is able to distinguish the major growth hormone isoform (GH1, 22 kDa) from other isoforms and quantify it without any interference across the clinically relevant concentration range of 0.5 to 50 ng/mL. Analysis involves purification of a 100-pt serum sample by immunocapture using an anti-GH-directed antibody, tryptic digestion, and LC-MS/MS quantification of an isoform-specific signature peptide for GH1 (22 kDa). A tryptic peptide occurring in all GH isoforms is monitored in the same 16-min analytical run as a read-out for total GH. Stable-isotope-labeled forms of these two peptides are included as internal standards. Full validation of the method according to recent guidelines, against a recombinant form of the analyte in rat plasma calibrators, demonstrated intra-assay and interassay imprecision below 6% across the calibration range for both signature peptides and recoveries between 94 and 102%. An excellent correlation was found between nominal and measured concentrations of the WHO reference standard for GH1 (22 kDa). Addition of up to 1000 ng/mL biotin or the presence of a 100-fold excess of GH binding protein did not affect the measurement. Equivalent method performance was found for analysis of GH in serum, EDTA, and heparin plasma. Analyte stability was demonstrated during all normal sample storage conditions. Comparison with the IDS-iSYS GH immunoassay showed a good correlation with the LC-MS/MS method for the isoform-specific signature peptide, but a significant positive bias was observed for the LC-MS/MS results of the peptide representing total GH. This seems to confirm the actual occurrence of other GH isoforms in serum. Finally, in serum from pregnant individuals, no quantifiable GH1 (22 kDa) was found, but relatively high concentrations of total GH
Plasticity in metabolism of maternal androgens in avian embryos
Mothers can influence offspring phenotypes by transferring non-genetic information to the young, which provides them with a flexible tool to adjust the developmental trajectory of the young in fluctuating environments. Mothers can differentially deposit their resources in the same reproductive attempt in relation to the offspring position in the sibling hierarchy. However, whether embryos from different positions can be plastic in their response to the maternal signals, potentially leading to a mother–offspring conflict, is yet unclear. We used Rock pigeons (Columba livia), that lay two egg clutches where maternal androgen levels in second laid eggs at oviposition are higher than in first laid eggs, and investigated the plasticity of embryonic metabolism of maternal androgens. We experimentally elevated androstenedione and testosterone levels in first eggs to that present in second eggs and measured the change in androgen levels and its main metabolites (etiocholanolone and conjugated testosterone) after 3.5 days of incubation. We found that eggs with increased androgens show a different degree of androgen metabolism depending either on the egg laying sequence or initial androgen levels or both. Our findings indicate that embryos have certain plasticity in response to maternal androgen levels depending on maternal signals.</p
The influence of repeated injections on pharmacokinetics and biodistribution of different types of sterically stabilized immunoliposomes
AbstractSterically stabilized immunoliposomes (IL) with diameters of about 135 nm carrying mouse IgG, either coupled directly to the liposome surface, or linked to the terminal ends of grafted poly(ethylene glycol) (PEG) chains by a recently described conjugation procedure (Cyanur-PEG-PE), were intravenously injected into rats and the elimination kinetics and biodistribution were determined and compared with control liposomes. The amounts of conjugated antibodies were about 30 μg/μmol total lipid for all IL. In naive rats, plain pegylated liposomes displayed the longest blood circulation time, whereas the terminal-coupled IL exhibited the fastest elimination. Liposomes containing the underivatized anchor molecules circulate nearly as long as plain pegylated liposomes, indicating that the fast elimination of the IL can be attributed to the presence of antibodies.A second injection of identical liposomes 14 days after the first injection had a considerable influence on the pharmacokinetic parameters of the liposomes. The circulation time of plain pegylated liposomes drastically dropped by half and their uptake by the liver increased concomitantly, indicating that the PEG, upon repeated injection, ceases to function as an efficient barrier reducing opsonization and/or immune reactions. The circulation time of conventional IL was moderately reduced upon a second injection, whereas that of the terminally coupled IL was nearly unaffected. These differences among the IL demonstrate that the pharmacokinetic behavior of IL is strongly dependent on the antibody conjugation site on the liposome. The observed effects of repeated injections were similar for liposomes of 90-nm diameter. The phenomena described may have important implications for the repeated application of IL as drug carriers
Mass spectrometric quantification of urinary 6-sulfatoxymelatonin:age-dependent excretion and biological variation
Objectives: Regulators of circadian rhythm, including melatonin, influence fundamental biological processes. Measuring the melatonin metabolite 6-sulfatoxymelatonin in urine can estimate melatonin production. 6-sulfatoxymelatonin is mainly analyzed by immunoassays, but these methods are hampered by cross-reactivity and poor reproducibility when used to analyze small molecules. Therefore, we validated a high-throughput liquid chromatography with tandem mass spectrometry (LC-MS/MS) method to quantify 6-sulfatoxymelatonin in urine. We evaluated age-dependent 24-h excretion of 6-sulfatoxymelatonin into urine and the biological variation of urinary excretion in healthy individuals. Methods: The online solid phase extraction method combined with LC-MS/MS was validated according to international guidelines, and used to measure the excretion of 6-sulfatoxymelatonin into urine of 240 healthy individuals. Biological variation of 6-sulfatoxymelatonin excretion was examined in 10 healthy individuals. Results: Urinary 6-sulfatoxymelatonin results were well within the validation criteria (interassay coefficient of variation: Conclusions: This MS-based method enables straightforward, reproducible, and sensitive quantification of 6-sulfatoxymelatonin in urine. Urinary 6-sulfatoxymelatonin levels decreased with age. Biological variation of 6-sulfatoxymelatonin excretion into urine was high between subjects and lower within subjects, indicating that repeated measurements of 6-sulfatoxymelatonin in 24-h urine are needed in future studies
- …