    Hybrid fault diagnosis scheme implementation for power distribution systems automation

    No full text
    Power distribution automation and control are import-ant tools in the current restructured electricity markets. Unfortunately, due to its stochastic nature, distribution systems faults are hardly avoidable. This paper proposes a novel fault diagnosis scheme for power distribution systems, composed by three different processes: fault detection and classification, fault location, and fault section determination. The fault detection and classification technique is wavelet based. The fault-location technique is impedance based and uses local voltage and current fundamental phasors. The fault section determination method is artificial neural network based and uses the local current and voltage signals to estimate the faulted section. The proposed hybrid scheme was validated through Alternate Transient Program/Electromagentic Transients Program simulations and was implemented as embedded software. It is currently used as a fault diagnosis tool in a Southern Brazilian power distribution company.Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)Companhia Estadual de Distribuicao de Energia Eletrica do Rio Grande do Sul (CEEE-D)[TPWRD-00466-2007

    Extended Fault-Location Formulation for Power Distribution Systems

    No full text
    In this paper, an extended impedance-based fault-location formulation for generalized distribution systems is presented. The majority of distribution feeders are characterized by having several laterals, nonsymmetrical lines, highly unbalanced operation, and time-varying loads. These characteristics compromise traditional fault-location methods performance. The proposed method uses only local voltages and currents as input data. The current load profile is obtained through these measurements. The formulation considers load variation effects and different fault types. Results are obtained from numerical simulations by using a real distribution system from the Electrical Energy Distribution State Company of Rio Grande do Sul (CEEE-D), Southern Brazil. Comparative results show the technique robustness with respect to fault type and traditional fault-location problems, such as fault distance, resistance, inception angle, and load variation. The formulation was implemented as embedded software and is currently used at CEEE-D`s distribution operation center.Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)Companhia Estadual de Distribuicao de Energia Eletrica do Rio Grande do Sul (CEEE-D)[TPWRD-00673-2007
    corecore