6 research outputs found

    The SIJLAB Joint Laboratory and the design of a prototype Archimedes Bridge

    No full text
    In the paper the activity performed within the SIJLAB project(Sino-Italian Joint Laboratory of Archimedes Bridge) for the design of the first Archimedes Bridge to be built in the world are summarized. The prototype (100 m long with a tunnel section having an external diameter of 4.4 m) will be installed in a lake and initially used as a full-size laboratory for performing experiments on structural behaviour and on fluid-structure interaction phenomena; subsequently it will become a tourist attraction. Here criteria and solution adopted in the design, both at the section level and for the overall structural scheme are reviewed, along with the load conditions and the methods for structural analyses

    SEISMIC ISOLATION OF THE IRIS NUCLEAR PLANT

    No full text
    The safety-by-design™ approach adopted for the design of the International Reactor Innovative and Secure (IRIS) resulted in the elimination by design of some of the main accident scenarios classically applicable to Pressurized Water Reactors (PWR) and to the reduction of either consequences or frequency of the remaining classical at-power accident initiators. As a result of such strategy the Core Damage Frequency (CDF) from at-power internal initiating events was reduced to the 10-8/ry order of magnitude, thus elevating CDF from external events (seismic above all) to an even more significant contributor than what currently experienced in the existing PWR fleet. The same safety-by-design™ approach was then exported from the design of the IRIS reactor and of its safety systems to the design of the IRIS Nuclear Steam Supply System (NSSS) building, with the goal of reducing the impact of seismically induced scenarios. The small footprint of the IRIS NSSS building, which includes all Engineered Safety Features (ESF), all the emergency heat sink and all the required support systems makes the idea of seismic isolation of the entire nuclear island a relatively easy and economically competitive solution. The seismically isolated IRIS NSSS building dramatically reduces the seismic excitation perceived by the reactor vessel, the Containment structure and all the main IRIS ESF components, thus virtually eliminating the seismic-induced CDF. This solution is also contributing to the standardization of the IRIS plant, with a single design compatible with a variety of sites covering a wide spectrum of seismic conditions. The conceptual IRIS seismic isolation system is herein presented, along with a selection of the preliminary seismic analyses confirming the drastic reduction of the seismic excitation to the IRIS NSSS building. Along with the adoption of the seismic isolation system, a more refined approach to the computation of the fragility analysis of the components is also being developed, in order to reduce the undue conservatism historically affecting seismic analysis. The new fragility analysis methodology will be particularly focused on the analysis of the isolators themselves, which will now be the limiting components in the evaluation of the overall seismic induced CDF
    corecore