287 research outputs found
On border traps in back-side-illuminated CMOS image sensor oxides
CMOS image sensors (CISs) in back-side-illuminated configuration consist of photodiode arrays having metal lines and drive electronics beneath the active region with respect to the device/air interface so that the light reaches the photodiode active region directly. This enhances sensor quantum efficiency but reduces the electrical performance and reliability. The back-side configuration is realized by flipping the wafer upside down, bonding it to a handling wafer, mechanically thinning it, and opening a through-silicon via with a long plasma etch. As a result, gate oxides in back-side CISs show an increased density of donor-like border traps with respect to the conventional front-side-illuminated sensors. In this article, we try to add some information toward the comprehension of the origin and the electrical nature of those traps in back-side gate oxides. To this aim, we performed negative bias temperature instability stress on p-channel MOSFETs during which the traps were filled by holes tunneling from the substrate and then studied the relaxation transients of the drain current after the stress was removed. The characteristic emission times of a few specific levels were obtained at different temperatures. This allowed us to extract values of the trap activation energies, which resulted coherent with hole-capturing E′ donor-like centers (trivalent silicon dangling bonds) commonly attributed to ionizing radiation
model of reversible breakdown in hfo2 based on fractal patterns
We propose a model of the kinetics of reversible breakdown in metal-insulator-metal structures with afnia based on the growth of fractal patterns of defects when the insulator is subject to an external voltage. The probability that a defect is (or is not) generated and the position where it is generated depend on the electric field distribution. The new defect moves accordingly to fractal rules and attach to another defect in a tree branch. When the two electrodes sandwiching the insulating film are connected a conductive filament is formed and the breakdown takes place. The model is calibrated with experiments inducing metastable soft breakdown events in Pt/HfO2/Pt capacitors
Shedding light on nocturnal movements in parkinson’s disease: Evidence from wearable technologies
In Parkinson’s disease (PD), abnormal movements consisting of hypokinetic and hyperkinetic manifestations commonly lead to nocturnal distress and sleep impairment, which significantly impact quality of life. In PD patients, these nocturnal disturbances can reflect diseaserelated complications (e.g., nocturnal akinesia), primary sleep disorders (e.g., rapid eye movement behaviour disorder), or both, thus requiring different therapeutic approaches. Wearable technologies based on actigraphy and innovative sensors have been proposed as feasible solutions to identify and monitor the various types of abnormal nocturnal movements in PD. This narrative review addresses the topic of abnormal nocturnal movements in PD and discusses how wearable technologies could help identify and assess these disturbances. We first examine the pathophysiology of abnormal nocturnal movements and the main clinical and instrumental tools for the evaluation of these disturbances in PD. We then report and discuss findings from previous studies assessing nocturnal movements in PD using actigraphy and innovative wearable sensors. Finally, we discuss clinical and technical prospects supporting the use of wearable technologies for the evaluation of nocturnal movements
Electron-attachment rates for carbon-rich molecules in protoplanetary atmospheres: the role of chemical differences
The formation of anionic species in the interstellar medium from interaction
of linear molecules containing carbon, nitrogen and hydrogen as atomic
components (polyynes) with free electrons in the environment is modelled via a
quantum treatment of the collision dynamics. The ensuing integral cross
sections are employed to obtain the corresponding attachment rates over a broad
range of temperatures for the electrons. The calculations unequivocally show
that a parametrization form often employed for such rates yields a broad range
of values that turn out to be specific for each molecular species considered,
thus excluding using a unique set for the whole class of polyynes.Comment: accepted to be published on MNRA
Correlation between wearable inertial sensor data and standardised Parkinson's disease axial impairment measures using machine learning
Wearable sensors represent a valuable means for monitoring motion signs and symptoms of Parkinson’s disease (PD). In this paper, we explore the potential of a single inertial sensor to yield information correlated to the patient’s subjective perception of axial motion impairment during daily activities. This latter is expressed using as a relevant metric the sum of MDS-UPDRS items 2.11-2.13. Methods: thirty-one patients with PD were enrolled in this study, and asked to perform a timed-up-and-go test while wearing an inertial sensor on their thigh. Several time- and frequency-domain features were extracted from the inertial signals. They were fed to a random forest regression model for the prediction of the axial impairment metric. The model was optimized using 10-fold cross-validation and performance were assessed using leave-one-subject-out test. Results: Pearson correlation coefficient with the addressed metric of 0.76 (0.86) and mean absolute error of 1.70 (1.52) were obtained in patients under (not under) dopaminergic therapy. Moreover, moderate to strong correlations were found between the predicted score and some important disease progression, axial impairment, and motor performance metrics. Conclusion: a single wearable inertial sensor may be used for assessing motor disabilities of patients with PD
Flip-angle based ratiometric approach for pulsed CEST-MRI pH imaging
Several molecules have been exploited for developing MRI pH sensors based on the chemical exchange saturation transfer (CEST) technique. A ratiometric approach, based on the saturation of two exchanging pools at the same saturation power, or by varying the saturation power levels on the same pool, is usually needed to rule out the concentration term from the pH measurement. However, all these methods have been demonstrated by using a continuous wave saturation scheme that limits its translation to clinical scanners. This study shows a new ratiometric CEST-MRI pH-mapping approach based on a pulsed CEST saturation scheme for a radiographic contrast agent (iodixanol) possessing a single chemical exchange site. This approach is based on the ratio of the CEST contrast effects at two different flip angles combinations (180°/360° and 180°/720°), keeping constant the mean irradiation RF power (Bavg power). The proposed ratiometric approach index is concentration independent and it showed good pH sensitivity and accuracy in the physiological range between 6.0 and 7.4
Objective assessment of walking impairments in myotonic dystrophy by means of a wearable technology and a novel severity index
Myotonic dystrophy type 1 (DM1) is a genetic inherited autosomal dominant disease characterized by multisystem involvement, including muscle, heart, brain, eye, and endocrine system. Although several methods are available to evaluate muscle strength, endurance, and dexterity, there are no validated outcome measures aimed at objectively evaluating qualitative and quantitative gait alterations. Advantageously, wearable sensing technology has been successfully adopted in objectifying the assessment of motor disabilities in different medical occurrences, so that here we consider the adoption of such technology specifically for DM1. In particular, we measured motor tasks through inertial measurement units on a cohort of 13 DM1 patients and 11 healthy control counterparts. The motor tasks consisted of 16 meters of walking both at a comfortable speed and fast pace. Measured data consisted of plantar-flexion and dorsi-flexion angles assumed by both ankles, so to objectively evidence the footdrop behavior of the DM1 disease, and to define a novel severity index, termed SI-Norm2, to rate the grade of walking impairments. According to the obtained results, our approach could be useful for a more precise stratification of DM1 patients, providing a new tool for a personalized rehabilitation approach
Photonic Torque Microscopy of the Nonconservative Force Field for Optically Trapped Silicon Nanowires
We measure, by photonic torque microscopy, the nonconservative rotational motion arising from the transverse components of the radiation pressure on optically trapped, ultrathin silicon nanowires. Unlike spherical particles, we find that nonconservative effects have a significant influence on the nanowire dynamics in the trap. We show that the extreme shape of the trapped nanowires yields a transverse component of the radiation pressure that results in an orbital rotation of the nanowire about the trap axis. We study the resulting motion as a function of optical power and nanowire length, discussing its size-scaling behavior. These shape-dependent nonconservative effects have implications for optical force calibration and optomechanics with levitated nonspherical particles
Beneficial Effects of Polydeoxyribonucleotide (PDRN) in an In Vitro Model of Fuchs Endothelial Corneal Dystrophy
Fuchs endothelial corneal dystrophy (FECD) is a bilateral, hereditary syndrome characterized by progressive irreversible injury in the corneal endothelium; it is the most frequent cause for corneal transplantation worldwide. Oxidative stress induces the apoptosis of corneal endothelial cells (CECs), and has a crucial function in FECD pathogenesis. The stimulation of the adenosine A2A receptor (A2Ar) inhibits oxidative stress, reduces inflammation and modulates apoptosis. Poly-deoxyribonucleotide (PDRN) is a registered drug that acts through adenosine A2Ar. Thus, the goal of this study was to assess the effect of PDRN in an in vitro FECD model. Human Corneal Endothelial Cells (IHCE) were challenged with H2O2 (200 µM) alone or in combination with PDRN (100 µg/mL), PDRN plus ZM241385 (1 µM) as an A2Ar antagonist, and CGS21680 (1 µM) as a well-known A2Ar agonist. H2O2 reduced the cells’ viability and increased the expression of the pro-inflammatory markers NF-κB, IL-6, IL-1β, and TNF-α; by contrast, it decreased the expression of the anti-inflammatory IL-10. Moreover, the pro-apoptotic genes Bax, Caspase-3 and Caspase-8 were concurrently upregulated with a decrease of Bcl-2 expression. PDRN and CGS21680 reverted the negative effects of H2O2. Co-incubation with ZM241385 abolished the effects of PDRN, indicating that A2Ar is involved in the mode of action of PDRN. These data suggest that PDRN defends IHCE cells against H2O2-induced damage, potentially as a result of its antioxidant, anti-inflammatory and antiapoptotic properties, suggesting that PDRN could be used as an FECD therapy
- …