131 research outputs found

    Quantification and Assessment of Interfraction Setup Errors Based on Cone Beam CT and Determination of Safety Margins for Radiotherapy

    Get PDF
    Introduction To quantify interfraction patient setup-errors for radiotherapy based on cone-beam computed tomography and suggest safety margins accordingly. Material and Methods Positioning vectors of pre-treatment cone-beam computed tomography for different treatment sites were collected (n = 9504). For each patient group the total average and standard deviation were calculated and the overall mean, systematic and random errors as well as safety margins were determined Results The systematic (and random errors) in the superior-inferior, left-right and anterior-posterior directions were: for prostate, 2.5(3.0), 2.6(3.9) and 2.9(3.9) mm; for prostate bed, 1.7(2.0), 2.2(3.6) and 2.6(3.1) mm; for cervix, 2.8(3.4), 2.3(4.6) and 3.2(3.9) mm; for rectum, 1.6(3.1), 2.1(2.9) and 2.5(3.8) mm; for anal, 1.7(3.7), 2.1(5.1) and 2.5(4.8) mm; for head and neck, 1.9(2.3), 1.4(2.0) and 1.7(2.2) mm; for brain, 1.0(1.5), 1.1(1.4) and 1.0(1.1) mm; and for mediastinum, 3.3(4.6), 2.6(3.7) and 3.5(4.0) mm. The CTV-to-PTV margins had the smallest value for brain (3.6, 3.7 and 3.3mm) and the largest for mediastinum (11.5, 9.1 and 11.6mm). For pelvic treatments the means (and standard deviations) were 7.3 (1.6), 8.5 (0.8) and 9.6 (0.8) mm. Conclusions Systematic and random setup-errors were smaller than 5mm. The largest errors were found for organs with higher motion probability. The suggested safety margins were comparable to published values in previous but often smaller studies

    Radiotherapy for tumors of the stomach and gastroesophageal junction - a review of its role in multimodal therapy

    Get PDF
    There is broad consensus on surgical resection being the backbone of curative therapy of gastric- and gastroesophageal junction carcinoma. Nevertheless, details on therapeutic approaches in addition to surgery, such as chemotherapy, radiotherapy or radiochemotherapy are discussed controversially; especially whether external beam radiotherapy should be applied in addition to chemotherapy and surgery is debated in both entities and differs widely between regions and centers. Early landmark trials such as the Intergroup-0116 and the MAGIC trial must be interpreted in the context of potentially insufficient lymph node resection. Despite shortcomings of both trials, benefits on overall survival by radiochemotherapy and adjuvant chemotherapy were confirmed in populations of D2-resected gastric cancer patients by Asian trials. Recent results on junctional carcinoma patients strongly suggest a survival benefit of neoadjuvant radiochemotherapy in curatively resectable patients. An effect of chemotherapy in the perioperative setting as given in the MAGIC study has been confirmed by the ACCORD07 trial for junctional carcinomas; however both the studies by Stahl et al. and the excellent outcome in the CROSS trial as compared to all other therapeutic approaches indicate a superiority of neoadjuvant radiochemotherapy as compared to perioperative chemotherapy in junctional carcinoma patients. Surgery alone without neoadjuvant or perioperative therapy is considered suboptimal in patients with locally advanced disease. In gastric carcinoma patients, perioperative chemotherapy has not been compared to adjuvant radiochemotherapy in a randomized setting. Nevertheless, the results of the recently published ARTIST trial and the Chinese data by Zhu and coworkers, indicate a superiority of adjuvant radiochemotherapy as compared to adjuvant chemotherapy in terms of disease free survival in Asian patients with advanced gastric carcinoma. The ongoing CRITICS trial is supposed to provide reliable conclusions about which therapy should be preferred in Western patients with gastric carcinoma. If radiotherapy is performed, modern approaches such as intensity-modulated radiotherapy and image guidance should be applied, as these methods reduce dose to organs at risk and provide a more homogenous coverage of planning target volumes

    Hypofractionated image-guided breath-hold SABR (Stereotactic Ablative Body Radiotherapy) of liver metastases - clinical results

    Get PDF
    Purpose: Stereotactic Ablative Body Radiotherapy (SABR) is a non-invasive therapy option for inoperable liver oligometastases. Outcome and toxicity were retrospectively evaluated in a single-institution patient cohort who had undergone ultrasound-guided breath-hold SABR. Patients and methods: 19 patients with liver metastases of various primary tumors consecutively treated with SABR (image-guidance with stereotactic ultrasound in combination with computer-controlled breath-hold) were analysed regarding overall-survival (OS), progression-free-survival (PFS), progression pattern, local control (LC), acute and late toxicity. Results: PTV (planning target volume)-size was 108 +/- 109cm(3) (median 67.4 cm(3)). BED2 (Biologically effective dose in 2 Gy fraction) was 83.3 +/- 26.2 Gy (median 78 Gy). Median follow-up and median OS were 12 months. Actuarial 2-year-OS-rate was 31%. Median PFS was 4 months, actuarial 1-year-PFS-rate was 20%. Site of first progression was predominantly distant. Regression of irradiated lesions was observed in 84% (median time to detection of regression was 2 months). Actuarial 6-month-LC-rate was 92%, 1- and 2-years-LC-rate 57%, respectively. BED2 influenced LC. When a cut-off of BED2 = 78 Gy was used, the higher BED2 values resulted in improved local control with a statistical trend to significance (p = 0.0999). Larger PTV-sizes, inversely correlated with applied dose, resulted in lower local control, also with a trend to significance (p-value = 0.08) when a volume cut-off of 67 cm(3) was used. No local relapse was observed at PTV-sizes < 67 cm(3) and BED2 > 78 Gy. No acute clinical toxicity > degrees 2 was observed. Late toxicity was also <= degrees 2 with the exception of one gastrointestinal bleeding-episode 1 year post-SABR. A statistically significant elevation in the acute phase was observed for alkaline-phosphatase; in the chronic phase for alkaline-phosphatase, bilirubine, cholinesterase and C-reactive protein. Conclusions: A trend to statistically significant correlation of local progression was observed for BED2 and PTV-size. Dose-levels BED2 > 78 Gy cannot be reached in large lesions constituting a significant fraction of this series. Image-guided SABR (igSABR) is therefore an effective non-invasive treatment modality with low toxicity in patients with small inoperable liver metastases

    Interobserver agreement on definition of the target volume in stereotactic radiotherapy for pancreatic adenocarcinoma using different imaging modalities

    Full text link
    PURPOSE The aim of this study was to evaluate interobserver agreement (IOA) on target volume definition for pancreatic cancer (PACA) within the Radiosurgery and Stereotactic Radiotherapy Working Group of the German Society of Radiation Oncology (DEGRO) and to identify the influence of imaging modalities on the definition of the target volumes. METHODS Two cases of locally advanced PACA and one local recurrence were selected from a large SBRT database. Delineation was based on either a planning 4D CT with or without (w/wo) IV contrast, w/wo PET/CT, and w/wo diagnostic MRI. Novel compared to other studies, a combination of four metrics was used to integrate several aspects of target volume segmentation: the Dice coefficient (DSC), the Hausdorff distance (HD), the probabilistic distance (PBD), and the volumetric similarity (VS). RESULTS For all three GTVs, the median DSC was 0.75 (range 0.17-0.95), the median HD 15 (range 3.22-67.11) mm, the median PBD 0.33 (range 0.06-4.86), and the median VS was 0.88 (range 0.31-1). For ITVs and PTVs the results were similar. When comparing the imaging modalities for delineation, the best agreement for the GTV was achieved using PET/CT, and for the ITV and PTV using 4D PET/CT, in treatment position with abdominal compression. CONCLUSION Overall, there was good GTV agreement (DSC). Combined metrics appeared to allow a more valid detection of interobserver variation. For SBRT, either 4D PET/CT or 3D PET/CT in treatment position with abdominal compression leads to better agreement and should be considered as a very useful imaging modality for the definition of treatment volumes in pancreatic SBRT. Contouring does not appear to be the weakest link in the treatment planning chain of SBRT for PACA

    Intrafraction motion of the prostate during an IMRT session: a fiducial-based 3D measurement with Cone-beam CT

    Get PDF
    Background: Image-guidance systems allow accurate interfractional repositioning of IMRT treatments, however, these may require up to 15 minutes. Therefore intrafraction motion might have an impact on treatment precision. 3D geometric data regarding intrafraction prostate motion are rare; we therefore assessed its magnitude with pre- and post-treatment fiducial-based imaging with cone-beam-CT (CBCT). Methods: 39 IMRT fractions in 5 prostate cancer patients after (125)I-seed implantation were evaluated. Patient position was corrected based on the (125)I-seeds after pre-treatment CBCT. Immediately after treatment delivery, a second CBCT was performed. Differences in bone- and fiducial position were measured by seed-based grey-value matching. Results: Fraction time was 13.6 +/- 1.6 minutes. Median overall displacement vector length of (125)Iseeds was 3 mm (M = 3 mm, Sigma = 0.9 mm, sigma = 1.7 mm; M: group systematic error, Sigma: SD of systematic error, sigma: SD of random error). Median displacement vector of bony structures was 1.84 mm (M = 2.9 mm, Sigma = 1 mm, sigma = 3.2 mm). Median displacement vector length of the prostate relative to bony structures was 1.9 mm (M = 3 mm, Sigma = 1.3 mm, sigma = 2.6 mm). Conclusion: a) Overall displacement vector length during an IMRT session is < 3 mm. b) Positioning devices reducing intrafraction bony displacements can further reduce overall intrafraction motion. c) Intrafraction prostate motion relative to bony structures is < 2 mm and may be further reduced by institutional protocols and reduction of IMRT duration

    Stereotactic or conformal radiotherapy for adrenal metastases: patient characteristics and outcomes in a multicenter analysis

    Get PDF
    To report outcome (freedom from local progression: FFLP, overall survival: OS, and toxicity) after stereotactic, palliative, or highly conformal fractionated (> 12) radiotherapy (SBRT, Pall-RT, 3DCRT/IMRT) for adrenal metastases in a retrospective multicenter cohort within the framework of the German Society for Radiation Oncology (DEGRO). Adrenal metastases treated with SBRT (≤ 12 fractions, biologically effective dose, (BED10) ≥ 50 Gy), 3DCRT/IMRT (> 12 fractions, BED10 ≥ 50 Gy) or Pall-RT (BED10 < 50 Gy) were eligible for this analysis. In addition to unadjusted FFLP (Kaplan-Meier/Log-rank), we calculated the competing-risk-adjusted local recurrence rate (CRA-LRR). 326 patients with 366 metastases were included by 21 centers (median follow-up: 11.7 months). Treatment was SBRT, 3DCRT/IMRT, and Pall-RT in 260, 27, and 79 cases, respectively. Most frequent primary tumors were non-small-cell lung cancer (NSCLC; 52.5%), SCLC (16.3%), and melanoma (6.7%). Unadjusted FFLP was higher after SBRT v. Pall-RT (p = 0.026) while numerical differences in CRA-LRR between groups did not reach statistical significance (1-year CRA-LRR: 13.8%, 17.4%, and 27.7%). OS was longer after SBRT v. other groups (p < 0.05) and increased in patients with locally-controlled metastases in a landmark analysis (p < 0.0001). Toxicity was mostly mild; notably, 4 cases of adrenal insufficiency occurred, 2 of which were likely caused by immunotherapy or tumor progression. RT for adrenal metastases was associated with a mild toxicity profile in all groups and a favorable 1-year CRA-LRR after SBRT or 3DCRT/IMRT. 1-year FFLP was associated with longer OS. Dose-response analyses for the dataset are underway

    Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM).</p> <p>Methods and materials</p> <p>Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy (IMRT) or three-dimensional conformal radiotherapy (3D-CRT) of the head and neck (n = 31), chest (n = 72), abdomen (n = 15), and pelvis (n = 30) were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes (PTV). In 25 patients, two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification, online verification once a week and online verification every other day.</p> <p>Results</p> <p>The SM could be effectively reduced with increasing frequency of online verifications. However, a significant frequency of relevant set-up errors remained even after online verification every other day. For example, residual set-up errors larger than 5 mm were observed on average in 18% to 27% of all fractions of patients treated in the chest, abdomen and pelvis, and in 10% of fractions of patients treated in the head and neck after online verification every other day.</p> <p>Conclusion</p> <p>In patients where high set-up accuracy is desired, daily online verification is highly recommended.</p
    corecore