92 research outputs found

    Downgrade of cardiac defibrillator devices to pacemakers in elderly heart failure patients:clinical considerations and the importance of shared decision-making

    Get PDF
    Implantable cardioverter defibrillators are implanted on a large scale in patients with heart failure (HF) for the prevention of sudden cardiac death. There are different scenarios in which defibrillator therapy is no longer desired or indicated, and this is occurring increasingly in elderly patients. Usually device therapy is continued until the device has reached battery depletion. At that time, the decision needs to be made to either replace it or to downgrade to a pacing-only device. This decision is dependent on many factors, including the vitality of the patient and his/her preferences, but may also be influenced by changes in recommendations in guidelines. In the last few years, there has been an increased awareness that discussions around these decisions are important and useful. Advanced care planning and shared decision-making have become important and are increasingly recognised as such. In this short review we describe six elderly patients with HF, in whose cases we discussed these issues, and we aim to provide some scientific and ethical rationale for clinical decision-making in this context. Current guidelines advocate the discussion of end-of-life options at the time of device implantation, and physicians should realise that their choices influence patients' options in this critical phase of their illness

    Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation

    Get PDF
    Background: Cryoballoon pulmonary vein isolation (PVI) is a common therapy for atrial fibrillation (AF). While moderately increased sinus rhythm heart rate (HR) after PVI has been observed, inappropriate sinus tachycardia (IST) is a rare phenomenon. We aimed to investigate the prevalence and natural history of an abnormal sinus HR response after cryoballoon PVI. Methods: We included 169/646 (26.2%) patients with AF undergoing PVI with available Holter recordings before and 3, 6 and 12 months after the procedure. Patients with AF on Holter monitoring were excluded. Mean HR increase >= 20 bpm or an IST-like pattern (mean HR > 90 bpm or > 80 bpm when beta-blocking agents were used) following PVI was categorised as abnormal sinus HR response. Results: Following PVI, mean HR +/- standard deviation increased in the entire group from 63.5 +/- 8.4 to 69.1 +/- 9.9 bpm at 3 months (p < 0.001), and to 71.9 +/- 9.4 bpm at 6 months (p < 0.001). At 12 months, mean HR was 71.2 +/- 10.1 bpm (p < 0.001). Only 7/169 patients (4.1%) met criteria for abnormal sinus HR response: mean HR was 61.9 +/- 10.6 bpm (pre-ablation), 84.6 +/- 9.8 bpm (3 months), 80.1 +/- 6.5 bpm (6 months) and 76.3 +/- 10.1 bpm (12 months). Even at 12 months, mean HR was significantly different from that pre-ablation in this group (p = 0.033). However, in patients meeting IST-like pattern criteria, mean HR at 12 months was no longer significantly different from that pre-ablation. Conclusion: Few patients had an abnormal sinus HR response after PVI. Peak HR was observed 3 months after PVI, but HR was still significantly increased 12 months post-ablation compared with pre-ablation. An IST-like pattern was rarely observed. In these patients, HR decreased to pre-ablation values within a year

    Assessment of sex-related differences and outcome in patients who underwent cryoballoon pulmonary vein isolation for atrial fibrillation:an observational cohort study

    Get PDF
    OBJECTIVES: Pulmonary vein isolation (PVI) is widely accepted as an effective and safe treatment for symptomatic atrial fibrillation (AF). However, data on sex-related differences and associations with clinical outcome and safety of PVI with cryoballoon ablation are limited. We sought to compare sexrelated efficacy and safety of cryoballoon ablation and identify sex-related associations with clinical outcomes. METHODS AND RESULTS: We included 650 consecutive patients with AF undergoing PVI with cryoballoon ablation at our institution between 2013 and 2017. The efficacy outcome was the first documented recurrence (>30 s) of AF, atrial flutter or atrial tachycardia (AF/AT) or repeat ablation during follow-up, after a 90-day blanking period. The safety outcome was the incidence of periprocedural complications. Mean age of the population was 58±10, and 210 (32.3%) patients were women. Women were older, had a higher body mass index, had more renal dysfunction and less coronary artery disease as compared with men. The rate of AF/AT recurrence was similar between women and men at 12-month follow-up (27.6% vs 24.8%, p=0.445). The incidence of periprocedural complications was higher in women (12.9% vs 4.6%; p<0.001), specifically groin haematomas and phrenic nerve palsy. On multivariate analysis, left atrial volume index (adjusted OR 1.05, 95% CI 1.00 to 1.10; p=0.032) was associated with the incidence of procedural complications in women. For men, no relation with complications could be found. CONCLUSION: The efficacy of cryoballoon ablation was similar between women and men; however, women had a higher risk of procedural complications

    Identifying patients with atrial fibrillation recurrences after two pulmonary vein isolation procedures

    Get PDF
    INTRODUCTION: Pulmonary vein isolation (PVI) is an important treatment for atrial fibrillation (AF). However, many patients need more than one procedure to maintain long-term sinus rhythm. Even after two PVIs some may suffer from AF recurrences. We aimed to identify characteristics of patients who fail after two PVI procedures. METHODS AND RESULTS: We included 557 consecutive patients undergoing a first PVI procedure with a second-generation 28 mm cryoballoon. Follow-up procedures were performed using radiofrequency ablation targeting reconnected PVs only. Recurrent AF was defined as any episode of AF lasting >30 s on ECG or 24 hour Holter monitoring performed at 3, 6 and 12 months post procedure. Mean age was 59.1±10.2 years, 383 (68.8%) were male, 448 (80.4%) had paroxysmal AF and the most common underlying condition was hypertension (36.6%). A total of 140/557 (25.1%) patients underwent redo procedure with PVI only. Of these patients 45 (32.4%) had recurrence of AF. These patients were comparable regarding age and sex to those in sinus rhythm after one or two procedures. Multivariate logistic regression showed that non-paroxysmal AF (OR 1.08 (95% CI 1.01 to 1.15), estimated glomerular filtration rate (OR 0.96, 95% CI 0.94 to 0.99), bundle branch block (OR 4.17, 95% CI 1.38 to 12.58), heart failure (OR 4.17, 95% CI 1.38 to 12.58) and Left Atrium Volume Index (OR 1.04, 95% CI 1.01 to 1.08) were associated with AF recurrence after two PVIs. The area under the curve for the identified risk factors was 0.74. CONCLUSIONS: Using a PVI-only approach, recurrence of AF after two AF ablation procedures is associated with more advanced underlying disease and persistent types of AF

    Advanced glycation end-products, a pathophysiological pathway in the cardiorenal syndrome

    Get PDF
    The prevalence of heart failure (HF) is increasing. A distinction is made between diastolic HF (preserved left ventricular ejection fraction (LVEF)) and systolic HF (reduced LVEF). Advanced glycation end-products (AGEs) are crystallized proteins that accumulate during ageing, but are particularly increased in patients with diabetes mellitus and in patients with renal failure. Through the formation of collagen crosslinks, and by interaction with the AGE-receptor, which impairs calcium handling and increases fibrosis, AGE-accumulation has pathophysiologically been associated with the development of diastolic and renal dysfunction. Interestingly, diastolic dysfunction is a frequent finding in elderly patients, diabetic patients and in patients with renal failure. Taken together, this suggests that AGEs are related to the development and progression of diastolic HF and renal failure. In this review, the role of AGEs as a possible pathophysiological factor that link the development and progression of heart and renal failure, is discussed. Finally, the role of AGE intervention as a possible treatment in HF patients will be discussed

    In-depth Characterization of Vaccine Breakthrough Infections With SARS-CoV-2 Among Health Care Workers in a Dutch Academic Medical Center

    Get PDF
    Severe acute respiratory syndrome coronavirus 2 infection after coronavirus disease 2019 vaccination raises concerns about the emergence of vaccine escape variants. Here we characterize 14 breakthrough infections among 5860 fully vaccinated Dutch health care workers ≥14 days after the final dose of vaccination with either BNT162b2, mRNA-1273, or Ad26.COV2.S. These breakthrough infections presented with regular B.1.1.7 (Alpha) and B.1.617.2 (Delta) variants and high viral loads, despite normal vaccine-induced B- and T-cell immune responses detected by live virus neutralization assays and ELISpot. High-risk exposure settings, such as in households, indicate a potential risk of viral transmission despite full vaccination