45 research outputs found

    Microfluidic cartridges preloaded with nanoliter plugs of reagents: an alternative to 96-well plates for screening

    Get PDF
    In traditional screening with 96-well plates, microliters of substrates are consumed for each reaction. Further miniaturization is limited by the special equipment and techniques required to dispense nanoliter volumes of fluid. Plug-based microfluidics confines reagents in nanoliter plugs (droplets surrounded by fluorinated carrier fluid), and uses simple pumps to control the flow of plugs. By using cartridges pre-loaded with nanoliter plugs of reagents, only two pumps and a merging junction are needed to set up a screen. Screening with preloaded cartridges uses only nanoliters of substrate per reaction, and requires no microfabrication. The low cost and simplicity of this method has the potential of replacing 96-well and other multi-well plates, and has been applied to enzymatic assays, protein crystallization and optimization of organic reactions

    Microgram-scale testing of reaction conditions in solution using nanoliter plugs in microfluidics with detection by MALDI-MS

    Get PDF
    This paper describes a microfluidic system to screen and optimize organic reaction conditions on a submicrogram scale. The system uses discrete droplets (plugs) as microreactors separated and transported by a continuous phase of a fluorinated carrier fluid. Previously, we demonstrated the use of a microfabricated PDMS plug-based microfluidic system to perform assays and crystallization experiments in aqueous solutions with optical detection. Here, we developed an approach that does not require microfabrication of microfluidic devices, is applicable to synthetic reactions in organic solvents, and uses detection by MALDI-MS. As a demonstration, conditions for selective deacetylation of ouabain hexaacetate were tested, and the optimum conditions for mono-, bis-, or trisdeacetylation have been identified. These conditions were validated by scale-up reactions and isolating these potentially neurotoxic products. Mono- and bisdeacetylated products are unstable intermediates in the deacetylation and were isolated for the first time. This system enables no-loss handling of submicroliter volumes containing a few micrograms of a compound of interest. It could become valuable for investigating or optimizing reactions of precious substrates (e.g., products of long synthetic sequences and natural products that can be isolated only in small quantities)

    Reactions in droplets in microfluidic channels

    Get PDF
    Fundamental and applied research in chemistry and biology benefits from opportunities provided by droplet-based microfluidic systems. These systems enable the miniaturization of reactions by compartmentalizing reactions in droplets of femoliter to microliter volumes. Compartmentalization in droplets provides rapid mixing of reagents, control of the timing of reactions on timescales from milliseconds to months, control of interfacial properties, and the ability to synthesize and transport solid reagents and products. Droplet-based microfluidics can help to enhance and accelerate chemical and biochemical screening, protein crystallization, enzymatic kinetics, and assays. Moreover, the control provided by droplets in microfluidic devices can lead to new scientific methods and insights

    Using microfluidics to observe the effect of mixing on nucleation of protein crystals

    Get PDF
    This paper analyzes the effect of mixing on nucleation of protein crystals. The mixing of protein and precipitant was controlled by changing the flow rate in a plug-based microfluidic system. The nucleation rate inversely depended on the flow rate, and flow rate could be used to control nucleation. For example, at higher supersaturations, precipitation happened at low flow rates while large crystals grew at high flow rates. Mixing at low flow velocities in a winding channel induces nucleation more effectively than mixing in straight channels. A qualitative scaling argument that relies on a number of assumptions is presented to understand the experimental results. In addition to helping fundamental understanding, this result may be used to control nucleation, using rapid chaotic mixing to eliminate formation of precipitates at high supersaturation and using slow chaotic mixing to induce nucleation at lower supersaturation

    Evaluation of short-term geomorphic changes in differently impacted gravel-bed rivers using improved dems of difference

    Get PDF
    The evaluation of the morphological dynamics of rivers is increasingly focusing, in recent years, on the achievement of quantitative estimates of change in order to identify geomorphic trends and forecast targeted restoration actions. Thanks to the development of more effective and reliable survey technologies, more accurate Digital Elevation Models (DEM) can be produced and, through their consequent differencing (DoD), extremely useful geomorphic analyses can be carried out. In this situation, a major role is played by uncertainty, especially in the final volumetric rates of erosion and deposition processes, that may lead to misinterpretation of spatial and temporal changes. This paper aims at achieving precise geomorphic estimates derived from subsequent hybrid (LiDAR and bathymetric points) surface representations. The study areas consist of gravel-bed reaches of two differently impacted fluvial environments, Piave and Tagliamento rivers, that were affected by two severe flood events (Piave, R.I. of 7 and 10 years and Tagliamento, R.I. of 15 and 12 years) in the inter-surveys period. The basic Hybrid Digital Elevation Models (HDTM) were processed accounting for spatially variable uncertainty and considering, beside slope and point density input variables, a novel component measuring the quality of the bathymetric derived points. In fact, since the major changes occur within river channels, the integration of this variable evaluating the precision of the bathymetric channel elevations in the HDTMs, has allowed, through the creation of targeted FIS (Fuzzy Inference System) rules, to obtain reliable geomorphic estimates of change. Volumes and erosion and deposition patterns were then analyzed and compared to outline the different dynamics among the sub-reaches and the two river systems

    Using three-phase flow of immiscible liquids to prevent coalescence of droplets in microfluidic channels: Criteria to identify the third liquid and validation with protein crystallization

    Get PDF
    This manuscript describes the effect of interfacial tensions on three-phase liquid-liquid-liquid flow in microfluidic channels and the use of this flow to prevent microfluidic plugs from coalescing. One problem in using microfluidic plugs as microreactors is the coalescence of adjacent plugs caused by the relative motion of plugs during flow. Here, coalescence of reagent plugs was eliminated by using plugs of a third immiscible liquid as spacers to separate adjacent reagent plugs. This work tested the requirements of interfacial tensions for plugs of a third liquid to be effective spacers. Two candidates satisfying the requirements were identified, and one of these liquids was used in the crystallization of protein human Tdp1 to demonstrate its compatibility with protein crystallization in plugs. This method for identifying immiscible liquids for use as a spacer will also be useful for applications involving manipulation of large arrays of droplets in microfluidic channels

    SlipChip for immunoassays in nanoliter volumes

    Get PDF
    This article describes a SlipChip-based approach to perform bead-based heterogeneous immunoassays with multiple nanoliter-volume samples. As a potential device to analyze the output of the chemistrode, the performance of this platform was tested using low concentrations of biomolecules. Two strategies to perform the immunoassay in the SlipChip were tested: (1) a unidirectional slipping method to combine the well containing a sample with a series of wells preloaded with reagents and (2) a back-and-forth slipping method to introduce a series of reagents to a well containing the sample by reloading and slipping the well containing the reagent. The SlipChips were fabricated with hydrophilic surfaces on the interior of the wells and with hydrophobic surfaces on the face of the SlipChip to enhance filling, transferring, and maintaining aqueous solutions in shallow wells. Nanopatterning was used to increase the hydrophobic nature of the SlipChip surface. Magnetic beads containing the capture antibody were efficiently transferred between wells and washed by serial dilution. An insulin immunoenzymatic assay showed a detection of limit of ∼13 pM. A total of 48 droplets of nanoliter volume were analyzed in parallel, including an on-chip calibration. The design of the SlipChip is flexible to accommodate other types of immunoassays, both heterogeneous and homogeneous. This work establishes the possibility of using SlipChip-based immunoassays in small volumes for a range of possible applications, including analysis of plugs from a chemistrode, detection of molecules from single cells, and diagnostic monitoring

    Using TIRF microscopy to quantify and confirm efficient mass transfer at the substrate surface of the chemistrode

    Get PDF
    This paper describes experiments for characterizing mass transfer at the hydrophilic surface of the substrate in a chemistrode. The chemistrode uses microfluidic plugs to deliver pulses of chemicals to a substrate with high temporal resolution, which requires efficient mass transfer between the wetting layer and the hydrophilic surface of the substrate. Here, total internal reflection fluorescence microscopy (TIRFM) was used to image the hydrophilic surface of the substrate as plugs were made to flow over it. The surface of the substrate was rapidly saturated with a fluorescent dye as the fluroesecent plugs passed over the substrate, confirming effective mass transfer between the wetting layer and the surface of the substrate. The dynamics of saturation are consistent from cycle to cycle, indicating that the chemistrode can stimulate surfaces with high reproducibility. The number of plugs required to reach 90% saturation of the hydrophilic surface of the substrate, φ(90%), only weakly depended on experimental conditions (the Péclet number or the capillary number). Furthermore, over a wide range of operating conditions, φ(90%) was less than 4. These results are useful for improving the chemistrode and for understanding other phenomena that involve diffusional transfer in multiphase or recirculating flows near surfaces
    corecore