21,341 research outputs found
Rate of heat extraction controller for environmental control
Automatic control device measures a physiological parameter related to heat production and conditions it to control the heat removal capacity of a watercooled environmental control suit
The development of an elastic reverse gradient garment to be used as a countermeasure for cardiovascular deconditioning
Using a new nomex lycra elastic fabric and individualized garment engineering techniques, reverse gradient garments (RGG's) were designed, constructed, and tested for effectiveness as a countermeasure against cardiovascular deconditioning. By combining torso compensated positive pressure breathing with a distally diminishing gradient of counterpressure supplied by the elastic fabric on the limbs, the RGG acts to pool blood in the extremities of recumbent persons much as though they were standing erect in 1 g. The RGG stresses the vasculature in a fashion similar to that experienced by the normally active man, hence preventing or limiting the development of post weightlessness orthostatic intolerance and related conditions. Four male, college age subjects received daily treatments with the RGG during a 15 day bedrest study. Four additional subjects also underwent the bedrest, but received no treatments; they served as controls. The preliminary indication was that the RGG was somewhat effective in limiting the deconditioning process
The principle of the space activity suit
Space activity suit designed for active astronaut working in vacuum environments for up to four hour
The development of an elastic reverse gradient garment to be used as a countermeasure for cardiovascular deconditioning
Using a new Nomex-Lycra elastic fabric and individualized garment engineering techniques, reverse gradient garments (RGG's) were designed, constructed, and tested for effectiveness as a countermeasure against cardiovascular deconditioning. By combining torso-compensated positive pressure breathing with a distally diminishing gradient of counterpressure supplied by the elastic fabric on the limbs, the RGG acts to pool blood in the extremities of recumbent persons much as though they were standing erect in 1 g. It was theorized that through the use of a dynamic pressurization scheme, the RGG would stress the vasculature in a fashion similar to that experienced by the noramlly active man, hence preventing or limiting the development of post-weightlessness orthostatic intolerance and related conditions. Four male, college-age subjects received daily treatments with the RGG during a 15-day bedrest study. Four additional subjects also underwent the bedrest, but received no treatments; they served as controls. The design and construction of the garments are described, and results of the treatment related measurements are given
The correspondence between small-scale coronal structures and the evolving solar magnetic field
Solar coronal bright points, first identified in soft X-rays as X-ray Bright Points (XBPs), are compact, short lived and associated with small bipolar magnetic flux. Contradictory studies have suggested that XBPs are either a primary signature of the emerging flux spectrum of the quiet Sun, or that they are representative of the disappearance of pre-existing flux. Results are presented using coordinated data obtained during recent X-ray sounding rocket flights on 15 August and 11 December 1987 to determine the correspondence of XBPs with time-series, ground based observations of evolving bipolar magnetic structures, He-I dark points, and the network. The results are consistent with the view that coronal bright points are more likely to be associated with the annihilation of pre-existing flux than with emerging flux
Cycles in metabolism and heat loss
Using calorimetric techniques, subjects' metabolism, thermoregulation, and body temperatures were monitored continuously for 24-hour days, using three types of experimental routines. A water cooling garment (WCG) was used for direct calorimetry, while partitional calorimetry was used to establish a non-suited comparison for one of the routines. In this replicated routine, called the quiet day, the subjects were sedentary throughout the daytime hours and slept normally at night. Results indicate that the WCG may act to reduce 24-hour total oxygen consumption (VO2) or heat production, possibly due to the lowered energy cost of thermoregulation
Retort braze bonding of borsic/aluminum composite sheet to titanium
Braze bonding studies between Borsic/aluminum composite and titanium sheet were conducted to establish acceptable brazing techniques and to assess potential joint efficiencies. Excellent braze joints were produced which exhibited joint strengths exceeding 117 MPa (17,000 psi) and which retained up to 2/3 of this strength at 589 K (600 F). Noticeable composite strength degradation resulting from the required high temperature braze cycle was found to be a problem
- …