312 research outputs found

    MinerAlert: an hybrid approach for web mining detection

    Get PDF
    The introduction of new memory-based crypto-mining techniques and the rise of new web technologies like WebAssembly, made the use of browsers for crypto-currencies mining more and more convenient and popular. That, in turn, originated a new form of computer piracy, called cryptojacking, which is rapidly gaining ground on the web. A cryptojacking site exploits its visitors’ hardware resources to secretly mine crypto-currencies. This paper analyzes current web-based cryptojacking detection methods in order to propose a novel hybrid strategy. Current detection methods are found to require either considerable computer administration skills or execution privileges usually not available to common users. In this view, a method, named MinerAlert, has been designed and proposed, aiming at detecting in real-time sites performing cryptojacking. To address the limitations of current methods, the method implementation has been achieved through a browser extension. The present paper describes the method’s details and its implementation. It also reports the experimental results of its utilization, showing its positive performances in terms of ease of use, successful detections and speed

    Development of glass-stalks-unsaturated polyester hybrid composites

    Get PDF
    The aim of this study is to investigate the possibility to use agro-residues of the vinification process as a cheaper and eco-friendly fillers to prepare unsaturated polyester composites for interior design building sector. Experimental unsaturated polyester–based resin composite samples, reinforced with grape stalks, were prepared by a simple casting technique. The glass microspheres were added in the mixing to increase the mechanical and physical properties of the final materials. A silane coupling agent was used to increase the interface adhesion between resin and grape stalks. The samples were subjected to several tests. Unfilled samples were analyzed by Differential Scanning calorimetry (DSC). Prepared silanized and non-silanized composites were completely characterized in order to study the effect of stalk fibers concentration on the mechanical, chemical and physical properties. The results showed that mechanical and physical properties for silanized composites were superior to non-silanized composites. The presence of stalks, up to 50% wt. increased Young's Modulus preserving a satisfactory tensile strength and hardness in comparison with the neat resin properties. Then, the final results showed that grape stalks from winemaking can be satisfactory used as natural filler resource to produce composites for interior furniture

    Urgent Carotid Surgery: Is It Still out of Debate?

    Get PDF
    Patients with symptomatic tight carotid stenosis have an increased short-time risk of stroke and an increased long-term risk of ischaemic vascular events compared with the general population. The aim of this study is to assess the safety, efficacy, and limitations of urgent CEA or CAS, in patients with carotid stenosis greater than 70% and clinically characterized by recurrent TIA or brain damage following a stroke (<2.5 cm). This study involved 28 patients divided into two groups. Group A consisted of sixteen patients who had undergone CEA, and group B consisted of twelve patients who had undergone CAS. Primary endpoints were mortality, neurological morbidity (by NIHSS) and postoperative hemorrhagic cerebral conversion, at 30 days. Ten patients (62.5%) of group A experienced an improvement in their initial neurological deficit while in 4 cases (26%) the deficit remained stable. Two cases of neurologic mortality are presented. At 1 month, 9 patients (75%) of group B experienced an improvement in their initial neurological deficit while 3 patients (25%) had a neurological impairment. Urgent or deferred surgical or endovascular treatment have a satisfactory outcome considering the profile in very high-risk patient population. Otherwise in selected patients CEA seems to be preferred to CAS

    Endovascular Abdominal Aortic Aneurysm Repair With Ovation Alto Stent Graft: Protocol for the ALTAIR (ALTo endogrAft Italian Registry) Study

    Get PDF
    Background: Since 2010, the Ovation Abdominal Stent Graft System has offered an innovative sealing option for abdominal aortic aneurysm (AAA) by including a sealing ring filled with polymer 13 mm from the renal arteries. In August 2020, the redesigned Ovation Alto, with a sealing ring 6 mm closer to the top of the fabric, received CE Mark approval. Objective: This registry study aims to evaluate intraoperative, perioperative, and postoperative results in patients treated by the Alto stent graft (Endologix Inc.) for elective AAA repair in a multicentric consecutive experience. Methods: All consecutive eligible patients submitted to endovascular aneurysm repair (EVAR) by Alto Endovascular AAA implantation will be included in this analysis. Patients will be submitted to EVAR procedures based on their own preferences, anatomical features, and operators experience. An estimated number of 300 patients submitted to EVAR with Alto stent graft should be enrolled. It is estimated that the inclusion period will be 24 months. The follow-up period is set to be 5 years. Full data sets and cross-sectional images of contrast-enhanced computed tomography scan performed before EVAR, at the first postoperative month, at 24 or 36 months, and at 5-year follow-up interval will be reported in the central database for a centralized core laboratory review of morphological changes. The primary endpoint of the study is to evaluate the technical and clinical success of EVAR with the Alto stent graft in short- (90-day), mid- (1-year), and long-term (5-year) follow-up periods. The following secondary endpoints will be also addressed: operative time; intraoperative radiation exposure; contrast medium usage; AAA sac shrinkage at 12-month and 5-year follow-up; any potential role of patients' baseline characteristics, valuated on preoperative computed tomography angiographic study, and of device configuration (number of component) in the primary endpoint. Results: The study is currently in the recruitment phase and the final patient is expected to be treated by the end of 2023 and then followed up for 5 years. A total of 300 patients will be recruited. Analyses will focus on primary and secondary endpoints. Updated results will be shared at 1- and 3-5-year follow-ups. Conclusions: The results from this registry study could validate the safety and effectiveness of the new design of the Ovation Alto Stent Graft. The technical modifications to the endograft could allow for accommodation of a more comprehensive range of anatomies on-label

    How to combine CTA, 99mTc-WBC SPECT/CT, and [18F]FDG PET/CT in patients with suspected abdominal vascular endograft infections?

    Get PDF
    Purpose - We aimed at comparing Tc-99m-HMPAO white blood cells (Tc-99m-WBC) scintigraphy, 18fluorine-fluorodeoxyglucose ([F-18]FDG) positron emission tomography/computed tomography (PET/CT) and CT angiography (CTA) in patients with suspected abdominal vascular graft or endograft infection (VGEI). Moreover, we attempted to define a new visual score for interpreting [F-18]FDG PET/CT scans aiming at increasing its specificity. Methods - We prospectively compared Tc-99m-WBC SPECT/CT, [F-18]FDG PET/CT, and CTA in 26 patients with suspected abdominal VGEI. WBC scans were performed and interpreted according to EANM recommendations. [F-18]FDG PET/CT studies were assessed with both qualitative (Sah's scale and new visual score) and semi-quantitative analyses. CTA images were interpreted according to MAGIC criteria. Microbiology, histopathology or a clinical follow-up of at least 24 months were used to achieve final diagnosis. Results - Eleven out of 26 patients were infected. [F-18]FDG PET/CT showed 100% sensitivity and NPV, with both scoring systems, thus representing an efficient tool to rule out the infection. The use of a more detailed scoring system provided statistically higher specificity compared to the previous Sah's scale (p = 0.049). Tc-99m-WBC SPECT/CT provided statistically higher specificity and PPV than [F-18]FDG PET/CT, regardless the interpretation criteria used and it can be, therefore, used in early post-surgical phases or to confirm or rule out a PET/CT finding. Conclusions - After CTA, patients with suspected late VGEI should perform a [F-18]FDG PET/CT given its high sensitivity and NPV. However, given its lower specificity, positive results should be confirmed with Tc-99m-WBC scintigraphy. The use of a more detailed scoring system reduces the number of Tc-99m-WBC scans needed after [F-18]FDG PET/CT. Nevertheless, in suspected infections within 4 months from surgery, Tc-99m-WBC SPECT/CT should be performed as second exam, due to its high accuracy in differentiating sterile inflammation from infection
    corecore