25 research outputs found
Demagnetization of Quantum Dot Nuclear Spins: Breakdown of the Nuclear Spin Temperature Approach
The physics of interacting nuclear spins arranged in a crystalline lattice is
typically described using a thermodynamic framework: a variety of experimental
studies in bulk solid-state systems have proven the concept of a spin
temperature to be not only correct but also vital for the understanding of
experimental observations. Using demagnetization experiments we demonstrate
that the mesoscopic nuclear spin ensemble of a quantum dot (QD) can in general
not be described by a spin temperature. We associate the observed deviations
from a thermal spin state with the presence of strong quadrupolar interactions
within the QD that cause significant anharmonicity in the spectrum of the
nuclear spins. Strain-induced, inhomogeneous quadrupolar shifts also lead to a
complete suppression of angular momentum exchange between the nuclear spin
ensemble and its environment, resulting in nuclear spin relaxation times
exceeding an hour. Remarkably, the position dependent axes of quadrupolar
interactions render magnetic field sweeps inherently non-adiabatic, thereby
causing an irreversible loss of nuclear spin polarization.Comment: 15 pages, 3 figure
Optical Detection of a Single Nuclear Spin
We propose a method to optically detect the spin state of a 31-P nucleus
embedded in a 28-Si matrix. The nuclear-electron hyperfine splitting of the
31-P neutral-donor ground state can be resolved via a direct frequency
discrimination measurement of the 31-P bound exciton photoluminescence using
single photon detectors. The measurement time is expected to be shorter than
the lifetime of the nuclear spin at 4 K and 10 T.Comment: 4 pages, 3 figure
Solid-state reference electrodes based on carbon nanotubes and polyacrylate membranes
A novel potentiometric solid-state reference electrode containing single-walled carbon nanotubes as the transducer layer between a polyacrylate membrane and the conductor is reported here. Single-walled carbon nanotubes act as an efficient transducer of the constant potentiometric signal originating from the reference membrane containing the Ag/AgCl/Cl− ions system, and they are needed to obtain a stable reference potentiometric signal. Furthermore, we have taken advantage of the light insensitivity of single-walled carbon nanotubes to improve the analytical performance characteristics of previously reported solid-state reference electrodes. Four different polyacrylate polymers have been selected in order to identify the most efficient reservoir for the Ag/AgCl system. Finally, two different arrangements have been assessed: (1) a solid-state reference electrode using photo-polymerised n-butyl acrylate polymer and (2) a thermo-polymerised methyl methacrylate:n-butyl acrylate (1:10) polymer. The sensitivity to various salts, pH and light, as well as time of response and stability, has been tested: the best results were obtained using single-walled carbon nanotubes and photo-polymerised n-butyl acrylate polymer. Water transport plays an important role in the potentiometric performance of acrylate membranes, so a new screening test method has been developed to qualitatively assess the difference in water percolation between the polyacrylic membranes studied. The results presented here open the way for the true miniaturisation of potentiometric systems using the excellent properties of single-walled carbon nanotubes