5,773 research outputs found

    HLA antibodies are associated with deterioration of kidney allograft function irrespective of donor specificity

    Full text link
    BACKGROUND Donor-specific antibodies are associated with high immunological risk and poor allograft outcome. Risk and clinical relevance of non-donor-specific HLA antibodies is less clear. METHODS A retrospective single-center study was conducted in all patients receiving a first kidney transplant at the University hospital of ZĂŒrich between 01/2006 and 02/2015. Patients were stratified into 3 groups having either no HLA antibodies at all (NoAB), HLA antibodies with donor specificity (DSA) and HLA antibodies without donor specificity (NonDSA). Allograft outcome was assessed using the slope of the estimated glomerular filtration rate (eGFR slope) starting at 12 months after transplantation. RESULTS During a median follow-up of 1808 days HLA antibodies were detected in 106 of 238 eligible patients (44%). Out of these, 73 patients (69%) had DSA and 33 patients (31%) had NonDSA only. Medium-term allograft function, as determined by eGFR slope over three years, improved in patients with NoAB (months 12-48: +0.7 ml/min/1.73 m2^{2}) but deteriorated significantly in patients with both DSA (months 12-48: -1.5 ml/min per1.73 m2^{2}/year, p = 0.015) and NonDSA (months 12-48: -1.8 ml/min per1.73 m2^{2}/year, p = 0.03) as compared to the group with NoAB. CONCLUSION Both, donor-specific and non-donor-specific HLA antibodies are associated with medium-term kidney allograft dysfunction as compared to patients with no HLA antibodies

    The Molecular Diagnosis Might Be Clinically Useful in Discrepant Kidney Allograft Biopsy Findings: An Analysis of Clinical Outcomes

    Full text link
    BACKGROUND The Molecular Microscope Diagnostic System (MMDx) may overcome histology shortcomings. Previous studies have simply examined discrepant findings but have not attempted to determine clinical endpoints. To measure performance, clinical outcomes are strongly required. METHODS This single-center cohort study described discrepancies between MMDx and histology from 51 kidney transplant recipients (KTRs) and analyzed 72 indication biopsies, including 21 follow-up biopsies. Clinical performance was assessed by a combined endpoint of graft failure, rejection on follow-up biopsy, de novo donor-specific antibody, and improvement of kidney allograft function upon antirejection treatment. RESULTS MMDx agreed in 33 (65%) and differed in 18 (35%) of 51 KTRs. Most discrepancies occurred in biopsies called no rejection by MMDx and rejection by histology (15/24, 63%). In contrast, in biopsies called rejection by MMDx, 3 were classified as no rejection by histology (3/27, 11%). Discrepant findings between MMDx and histology occurred following delayed graft function and MMDx from biopsies with a low percentage of cortex. Among 15 biopsies classified as no rejection by MMDx but rejection by histology, the clinical course suggested no rejection in 9 cases. Six KTRs reached the endpoint, showing predominant t ≄ 2 lesions. CONCLUSIONS The most often occurring discrepancy is rejection by histology but no rejection by MMDx. As more KTRs do not meet the combined endpoint for rejection, MMDx might be clinically useful in these discrepant cases. Although strong histological findings have priority in indicating the treatment, clinical implementation of MMDx could strengthen treatment strategies

    Impact of duration of chest tube drainage on pain after cardiac surgery.

    Get PDF
    OBJECTIVE: This study was designed to analyze the duration of chest tube drainage on pain intensity and distribution after cardiac surgery. METHODS: Two groups of 80 cardiac surgery adult patients, operated on in two different hospitals, by the same group of cardiac surgeons, and with similar postoperative strategies, were compared. However, in one hospital (long drainage group), a conservative policy was adopted with the removal the chest tubes by postoperative day (POD) 2 or 3, while in the second hospital (short drainage group), all the drains were usually removed on POD 1. RESULTS: There was a trend toward less pain in the short drainage group, with a statistically significant difference on POD 2 (P=0.047). There were less patients without pain on POD 3 in the long drainage group (P=0. 01). The areas corresponding to the tract of the pleural tube, namely the epigastric area, the left basis of the thorax, and the left shoulder were more often involved in the long drainage group. There were three pneumonias in each group and no patient required repeated drainage. CONCLUSIONS: A policy of early chest drain ablation limits pain sensation and simplifies nursing care, without increasing the need for repeated pleural puncture. Therefore, a policy of short drainage after cardiac surgery should be recommended

    Quantum equivalence in Poisson-Lie T-duality

    Full text link
    We prove that, general \s-models related by Poisson-Lie T-duality are quantum equivalent under one-loop renormalization group flow. We reveal general properties of the flows, we study the associated generalized coset models and provide explicit examples.Comment: 16 page

    Calibration and performance of the photon sensor response of FACT -- The First G-APD Cherenkov telescope

    Full text link
    The First G-APD Cherenkov Telescope (FACT) is the first in-operation test of the performance of silicon photo detectors in Cherenkov Astronomy. For more than two years it is operated on La Palma, Canary Islands (Spain), for the purpose of long-term monitoring of astrophysical sources. For this, the performance of the photo detectors is crucial and therefore has been studied in great detail. Special care has been taken for their temperature and voltage dependence implementing a correction method to keep their properties stable. Several measurements have been carried out to monitor the performance. The measurements and their results are shown, demonstrating the stability of the gain below the percent level. The resulting stability of the whole system is discussed, nicely demonstrating that silicon photo detectors are perfectly suited for the usage in Cherenkov telescopes, especially for long-term monitoring purpose

    FACT -- Operation of the First G-APD Cherenkov Telescope

    Full text link
    Since more than two years, the First G-APD Cherenkov Telescope (FACT) is operating successfully at the Canary Island of La Palma. Apart from its purpose to serve as a monitoring facility for the brightest TeV blazars, it was built as a major step to establish solid state photon counters as detectors in Cherenkov astronomy. The camera of the First G-APD Cherenkov Telesope comprises 1440 Geiger-mode avalanche photo diodes (G-APD aka. MPPC or SiPM) for photon detection. Since properties as the gain of G-APDs depend on temperature and the applied voltage, a real-time feedback system has been developed and implemented. To correct for the change introduced by temperature, several sensors have been placed close to the photon detectors. Their read out is used to calculate a corresponding voltage offset. In addition to temperature changes, changing current introduces a voltage drop in the supporting resistor network. To correct changes in the voltage drop introduced by varying photon flux from the night-sky background, the current is measured and the voltage drop calculated. To check the stability of the G-APD properties, dark count spectra with high statistics have been taken under different environmental conditions and been evaluated. The maximum data rate delivered by the camera is about 240 MB/s. The recorded data, which can exceed 1 TB in a moonless night, is compressed in real-time with a proprietary loss-less algorithm. The performance is better than gzip by almost a factor of two in compression ratio and speed. In total, two to three CPU cores are needed for data taking. In parallel, a quick-look analysis of the recently recorded data is executed on a second machine. Its result is publicly available within a few minutes after the data were taken. [...]Comment: 19th IEEE Real-Time Conference, Nara, Japan (2014

    Bladder cancer cells acquire competent mechanisms to escape Fas-mediated apoptosis and immune surveillance in the course of malignant transformation

    Get PDF
    Mechanisms of resistance against Fas-mediated cell killing have been reported in different malignancies. However, the biological response of immune escape mechanisms might depend on malignant transformation of cancer cells. In this study we investigated different mechanisms of immune escape in 2 well-differentiated low-grade (RT4 and RT112) and 2 poorly differentiated high-grade (T24 and TCCSUP) bladder cancer cell lines. Fas, the receptor of Fas-ligand, is expressed and shedded by human transitional bladder carcinoma cell lines RT4, RT112, T24 and TCCSUP. Cytotoxicity and apoptosis assays demonstrate that in spite of the Fas expression, poorly differentiated T24 and TCCSUP cells are insensitive towards either recombinant Fas-ligand or agonistic apoptosis-inducing monoclonal antibody against Fas. In poorly differentiated T24 and TCCSUP cell lines we were able to detect marked Fas-ligand protein by flow cytometry and Western blot analysis. In grade 1 RT4 and RT112 cells only minor expression of Fas-ligand possibly because of proteinase action. Fas-ligand mRNA translation or post-translational processing seems to be regulated differentially in the cancer cell lines depending on malignant transformation. In co-culture experiments we show that poorly differentiated cells can induce apoptosis and cell death in Jurkat cells and activated peripheral blood mononuclear cells. This in vitro study suggests that bladder cancer cells can take advantage of different mechanisms of immune evasion and become more competent in avoiding immune surveillance during transformation to higher-grade malignant disease. © 2001 Cancer Research Campaign www.bjcancer.co

    Low-lying quadrupole collective states of the light and medium Xenon isotopes

    Full text link
    Collective low lying levels of light and medium Xenon isotopes are deduced from the Generalized Bohr Hamiltonian (GBH). The microscopic seven functions entering into the GBH are built from a deformed mean field of the Woods-Saxon type. Theoretical spectra are found to be close to the ones of the experimental data taking into account that the calculations are completely microscopic, that is to say, without any fitting of parameters.Comment: 8 pages, 4 figures, 1 tabl

    Von KrÀutern zu Pillen, Biologics und NukleinsÀuren: Das Lipid-Management der Zukunft [The lipid management of the future: From herbs to pills, biologics and nucleic acids]

    Get PDF
    Pharmacotherapy has made massive advances: what began with herbs and fungi led to synthetic pills that interfered ever more precisely with receptors and metabolic pathways. Finally, antibodies against specific proteins became part of our therapeutic armamentarium. But none of these measures get to the heart of the matter: The latest revolutionary chapter in pharmacotherapy uses organ-specific nucleotides, short RNAsequences that intervene in pathogenic metabolic pathways even before proteins are formed and sometimes exert a very targeted effect over surprisingly long periods of time. In cardiovascular medicine, this pharmacotherapy of the future is mainly used in the treatment of lipometabolic disorders. RNAinterference technology involving the modified small interfering RNAtherapeutic inclisiran against the messenger RNAof proprotein convertase subtilisin/kexin type 9 (PCSK9) couples the therapeutic RNAwith N-acetylgalactosamine in order to achieve liver-specific silencing of the protein formation of PCSK9 by binding to the asialoglycoprotein receptors on the surface of hepatocytes. Thus, a marked and consistent reduction of PCSK9 and LDLcholesterol levels in plasma can be achieved over more than 6 months. Other developments use antisense oligonucleotides (ASOs) against angiopoietin-like protein 3 (ANGPTL3) or apolipoprotein C-III(apoC-III) to specifically lower triglyceride levels, and the ISIS-APO(a) Rx ASO, massively reduces (>70%) the formation of lipoprotein (a). These new RNA-targeted therapeutics have key advantages, such as a long duration of action, which relates to patient compliance, the specificity of their action in certain cells or organs and metabolic pathways, and they allow for the first time an effective treatment of hypertriglyceridaemia and the mostly genetically determined elevated levels of lipoprotein (a). Large randomised clinical trials testing the effect of these new nucleic acids on cardiovascular events such as myocardial infarction and death are currently underway, including in Switzerland, and will further determine the efficacy and safety of these new drugs. This will certainly herald a new era in the treatment of various cardiovascular diseases

    WARNING: Physics Envy May Be Hazardous To Your Wealth!

    Get PDF
    The quantitative aspirations of economists and financial analysts have for many years been based on the belief that it should be possible to build models of economic systems - and financial markets in particular - that are as predictive as those in physics. While this perspective has led to a number of important breakthroughs in economics, "physics envy" has also created a false sense of mathematical precision in some cases. We speculate on the origins of physics envy, and then describe an alternate perspective of economic behavior based on a new taxonomy of uncertainty. We illustrate the relevance of this taxonomy with two concrete examples: the classical harmonic oscillator with some new twists that make physics look more like economics, and a quantitative equity market-neutral strategy. We conclude by offering a new interpretation of tail events, proposing an "uncertainty checklist" with which our taxonomy can be implemented, and considering the role that quants played in the current financial crisis.Comment: v3 adds 2 reference
    • 

    corecore