93 research outputs found

    Concomitant ablation of atrial fibrillation in octogenarians: an observational study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiac surgery is increasingly required in octogenarians. These patients frequently present atrial fibrillation (AF), a significant factor for stroke and premature death. During the last decade, AF ablation has become an effective procedure in cardiac surgery. Because the results of concomitant AF ablation in octogenarians undergoing cardiac surgery are still not clear, we evaluated the outcome in these patients.</p> <p>Methods</p> <p>Among 200 patients undergoing concomitant AF ablation (87% persistent AF), 28 patients were ≥ 80 years (82 ± 2.4 years). The outcome was analysed by prospective follow up after 3, 6, 12 months and annually thereafter. Freedom from AF was calculated according to the Kaplan-Meier method.</p> <p>Results</p> <p>Octogenarians were similar to controls regarding AF duration (48 ± 63.2 versus 63 ± 86.3 months, n.s.) and left atrial diameter (49 ± 6.1 versus 49 ± 8.8 mm, n.s.), but differed in EuroSCORE (17.3 ± 10.93 versus 7.4 ± 7.31%, p < 0.001), prevalence of paroxysmal AF (25.0 versus 11.0%, p = 0.042) and aortic valve disease (67.8 versus 28.5%, p < 0.001). ICU stay (8 ± 16.9 versus 4 ± 7.2 days, p = 0.027), hospital stay (20 ± 23.9 versus 14 ± 30.8 days, p < 0.05), and 30-d-mortality (14.3 versus 4.6%, p = 0.046) were increased. After 12 ± 6.1 months of follow-up (95% complete), 14 octogenarians (82%) and 101 controls (68%, n.s.) were in sinus rhythm; 59% without antiarrhythmic drugs in either group (n.s.). Sinus rhythm restoration was associated with improved NYHA functional class and renormalization of left atrial size. Cumulative freedom from AF demonstrated no difference between groups. Late mortality was higher in octogenarians (16.7 versus 6.1%, p = 0.065).</p> <p>Conclusion</p> <p>Sinus rhythm restoration rate and functional improvement are satisfactory in octogenarians undergoing concomitant AF ablation. Hence, despite an increased perioperative risk, this procedure should be considered even in advanced age.</p

    Limiting esophageal temperature in radiofrequency ablation of left atrial tachyarrhythmias results in low incidence of thermal esophageal lesions

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Atrio-esophageal fistula formation following radiofrequency ablation of left atrial tachyarrhythmias is a rare but devastating complication. Esophageal injuries are believed to be precursors of fistula formation and reported to occur in up to 47% of patients. This study investigates the incidence of esophageal lesions when real time esophageal temperature monitoring and temperature limitation is used.</p> <p>Methods</p> <p>184 consecutive patients underwent open irrigated radiofrequency ablation of left atrial tachyarrhythmias. An esophageal temperature probe consisting of three independent thermocouples was used for temperature monitoring. A temperature limit of 40°C was defined to interrupt energy delivery. All patients underwent esophageal endoscopy the next day.</p> <p>Results</p> <p>Endoscopy revealed ulcer formation in 3/184 patients (1.6%). No patient developed atrio-esophageal fistula. Patient and disease characteristics had no influence on ulcer formation. The temperature threshold of 40°C was reached in 157/184 patients. A temperature overshoot after cessation of energy delivery was observed frequently. The mean maximal temperature was 40.8°C. Using a multiple regression analysis creating a box lesion that implies superior- and inferior lines at the posterior wall connecting the right and left encircling was an independent predictor of temperature. Six month follow-up showed an overall success rate of 78% documented as sinus rhythm in seven-day holter ECG.</p> <p>Conclusion</p> <p>Limitation of esophageal temperature to 40°C is associated with the lowest incidence of esophageal lesion formation published so far. This approach may contribute to increase the safety profile of radiofrequency ablation in the left atrium.</p

    HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation

    Get PDF
    During the past decade, catheter ablation of atrial fibrillation (AF) has evolved rapidly from a highly experimental unproven procedure, to its current status as a commonly performed ablation procedure in many major hospitals throughout the world. Surgical ablation of AF, using either standard or minimally invasive techniques, is also performed in many major hospitals throughout the world. The purpose of this Consensus Statement is to provide a state-of-the-art review of the field of catheter and surgical ablation of AF, and to report the findings of a Task Force, convened by the Heart Rhythm Society and charged with defining the indications, techniques, and outcomes of this procedure. The Heart Rhythm Society was pleased to develop this Consensus Statement in partnership with the European Heart Rhythm Association and the European Cardiac Arrhythmia Society. This statement summarizes the opinion of the Task Force members based on their own experience in treating patients, as well as a review of the literature, and is directed to all health care professionals who are involved in the care of patients with AF, particularly those who are undergoing or are being considered for catheter or surgical ablation procedures for AF. This statement is not intended to recommend or promote catheter ablation of AF. Rather the ultimate judgment regarding care of a particular patient must be made by the health care provider and patient in light of all the circumstances presented by that patient. In writing a "consensus" document, it is recognized that consensus does not mean that there was complete agreement among all Task Force members. We attempted to identify those aspects of AF ablation for which a true "consensus" could be identified ( Tables 1 and 2 ). Surveys of the entire Task Force were used to identify these areas of consensus. The main objective of this document is

    Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator

    Get PDF
    Purpose The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. Methods The study population consisted of 27 consecutive patients (age 68 +/- 8 years, 25 men, mean left ventricular ejection fraction 31 +/- 9%) with an old myocardial infarction and multiple and/or hemodynamically not tolerated ventricular tachycardia necessitating repeated device therapy. A total of 31 substrate modification procedures were performed using the three-dimensional electroanatomical mapping system. Patients were followed up for a median of 23.5 (interquartile range 6.5-53.2) months before and 37.8 (interquartile range 11.7-71.8) months after ablation. Antiarrhythmic drugs were not changed after the procedure, and were stopped 6 to 9 months after the procedure in patients who did not show ventricular tachycardia recurrence. Results Median ventricular tachycardias were 1.6 (interquartile range 0.7-6.7) per month before and 0.2 (interquartile range 0.00-1.3) per month after ablation (P = 0.006). Nine ventricular fibrillation episodes were registered in seven patients before and two after ablation (P = 0.025). Median antitachycardia pacing decreased from 1.6 (interquartile range 0.01-5.5) per month before to 0.18 (interquartile range 0.00-1.6) per month after ablation (P = 0.069). Median number of shocks decreased from 0.19 (interquartile range 0.04-0.81) per month before to 0.00 (interquartile range 0.00-0.09) per month after ablation (P = 0.001). One patient had a transient ischemic attack during the procedure, and another developed pericarditis. Nine patients died during follow-up, eight patients due to heart failure and one patient during valve surgery. Conclusion Catheter-based substrate modification using voltage mapping results in a long-lasting reduction of cardioverter defibrillator therapy in patients with multiple and/or hemodynamically not tolerated infarct-related ventricular tachyarrhythmia

    2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary.

    Get PDF
    S

    withdrawn 2017 hrs ehra ecas aphrs solaece expert consensus statement on catheter and surgical ablation of atrial fibrillation

    Get PDF
    n/

    2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary.

    Get PDF
    S
    corecore