    Ensayos de caracterización del comportamiento frente al agua de la piedra natural

    Get PDF
    This paper presents an experimental analysis of the stone behaviour in contact with water in the different construction uses. In any of these cases is analyse how the water penetrates into the material. As a result of the study the need of modification of the UNE test standards is concluded. It is proposed a procedure to determinate the material's properties and a method to compare and analyse the result obtained that keep into consideration the climate factors. The method have been applied to sandstone of Villamayor (Spain) showing its utility in the analysis of the stone properties.Se expone la necesidad de revisión de las normas UNE de ensayo para la determinación del comportamiento frente al agua de las rocas porosas teniendo en cuenta las formas de exposición que suponen las distintas aplicaciones constructivas y los mecanismos de penetración del agua que en cada caso operan. Se propone para ello una sistemática de ensayos y un método comparado de análisis de resultados basado en la consideración de los factores climatológicos. La utilidad del método se ilustra con un ejemplo de aplicación al estudio de la Arenisca de Villamayo

    Escayola reforzada por acción sinérgica entre aditivos del hormigón (fluidificantes, superfluidificantes y aireantes-plastificantes) y fibras de vidrio E

    Get PDF
    Through the analysis of the different compounds (plaster + additives + E glass fibres) we pretend to demostrate that a synergic action is present between certain concrete additives (superfluidifiers, fluidiflers, and airingplasticizers) and E glass fibre, on the basis of the flection resistance of plaster matrix based compound materials.Mediante el análisis de diferentes compuestos (escayola + aditivos + fibras de vidrio E) se pretende demostrar que existe una acción sinérgica entre ciertos aditivos del hormigón (superfluidificantes, fluidificantes y aireantes-plastificantes) y los refuerzos a base de fibras de vidrio E, sobre la resistencia a flexión de los materiales compuestos de matriz principal escayola

    Morteros de cemento mejorados con la adición de cenizas volantes carbonatadas provenientes de la incineración de residuos

    Get PDF
    This article presents the results of a research developing high performance cement mortars with the addition of municipal solid waste incineration fly ash (MSWIFA) stabilized as insoluble carbonates. The encapsulation of hazardous wastes in mortar matrixes has also been achieved. The ashes present high concentrations of chlorides, Zn and Pb. A stabilization process with NaHCO3 has been developed reducing 99% the content of chlorides. Developed mortars replace 10% per weight of the aggregates by treated MSWIFA. Physical/mechanical properties of these mortars have been studied. Presence of Zn, Pb, Cu and Cd has been also analyzed confirming that leaching of these heavy metal ions is mitigated. Conclusions prove better behavior of CAC and CSA mortars than those of CEM-I and CEM-II cement. Results are remarkable for the CAC mortars, improving reference strengths in more than 25%, which make them a fast-curing product suitable for the repair of structures or industrial pavements.Este artículo presenta los resultados del desarrollo de morteros mejorados con la incorporación de cenizas volantes de residuos sólidos urbanos inertizadas en forma de carbonatos. Además se consigue la encapsulación de un residuo peligroso. Las cenizas presentan una alta concentración de cloruros, Zn y Pb. Se ha desarrollado un proceso de estabilización con NaHCO3 reduciendo en un 99% el contenido de cloruros. Los morteros reemplazan un 10% en peso del árido por cenizas tratadas. Se han analizado sus propiedades físico/mecánicas y la presencia de Zn, Pb, Cu y Cd. Se demuestra un mejor comportamiento de los morteros de CAC y CSA que los de CEM-I y CEM-II y se mitiga el lixiviado de metales pesados. Los resultados son significativos en los morteros CAC al mejorar las resistencias de los de referencia en un 25%. Los morteros desarrollados son de curado rápido adecuados para la reparación de estructuras o soleras industriales

    Aumento de la tenacidad de hormigones autocompactables reforzados con fibras cortas de polipropileno

    Get PDF
    Increases in bending tests by the addition of low volume fractions of Polypropylene (PP) Short Fibers PP. These toughness increases are similar to those attained by Fiber Reinforced Concrete (FRC) referred elsewhere as Engineered Cementitious Composites (ECC), having some ductility and strain hardening in direct tensile and flexural tests. Concretes mixtures were manufactured using natural pozzolanic blended Portland cement, volcanic crushed coarse aggregates and fine sand from Sahara desert dunes (0-1 mm) from Canary Islands quarries and sand reservoirs, respectively, besides ordinary siliceous sand (0-4 mm) and fly ash from an anthracite-coal heat generator.Se presentan en este artículo hormigones autocompactables que, mediante la adición de pequeñas fracciones volumétricas de fibras cortas de polipropileno, consiguen incrementos importantes de tenacidad en su comportamiento mecánico a flexión. Estos aumentos de tenacidad son semejantes a los que presentan un grupo de hormigones reforzados con fibras, denominados ECC (Engineered Cementitious Composites), que muestran también alguna ductilidad y endurecimiento por deformación en ensayos de tracción directa y flexión. Los hormigones se dosificaron empleando cemento Pórtland con Puzolana natural, áridos volcánicos de machaqueo y arena fina procedente de dunas del desierto del Sáhara (0-1 mm), de canteras y depósitos de Las Palmas de Gran Canaria (Islas Canarias), respectivamente, además de arena silícea ordinaria (0-4 mm) y cenizas volantes de una central térmica de combustible antracita

    Inertización y valorización de polvos de lijado de barnices procedentes de residuos de la industria de la madera

    Get PDF
    The present article describes the findings of the first stageof the analysis of xiloarcilla, a material made of clayand a wood industry by-product, namely the wood andpolyurethane varnish powder pump-suctioned off woodcomponents during sanding and polishing. This powderwas added to the clay in proportions of from 1% to 5%by weight. The prime materials as well as the xiloarcillacompound were characterized, in the latter case primarilyto determine its physical-mechanical properties andchemical and environmental feasibility as a constructionmaterial.En este articulo se presentan los resultados obtenidos,en una primera etapa, del estudio del material que denominaremoscomo xiloarcilla, compuesto por arcilla y porun subproducto de las industrias de la madera, que eneste caso son los polvos del lijado y del barnizado y excedentesde estos productos utilizados en el acabado demuchos componentes de madera (PLB), estos polvos seadicionaron a la arcilla en cantidades entre el 1% y el5% del peso total del compuesto. Se realizo un estudiode caracterizacion de los materiales aislados y posteriormentedel compuesto xiloarcilla, con enfasis en el comportamientofisico-mecanico y su respuesta quimica ymedioambiental, como material de construccion

    Preparación de la dosificación de un hormigón con humo de sílice, cuya RMC sea > 40 kp/cm2, a edades iniciales (5-10 horas)

    Get PDF
    Silica fume (SF) or microsilica is related mainly with preparation of High Resistance Concrete. This has justified its use -together with portland cement (I-42'5/SR,MR) and an superfiuidifying additive- in the preparation of a concrete whose value for compressive mechanical resistance at early ages (only 5 to 10 hours) is higher than 40 kp/cm2, instead of preparing it with the portland cement plus a setting accelerator or "model" dosage. The experimental techniques used to reach that objective have been: ultrasound energy and a press for breaking 30 x 15 mm specimens, and a maximum load of 2001. With the first technique, in only 25 days, 13 different dossages were prepared, which were compared to the "model" dosage, and two more that did not contain neither setting accelerator nor SF, this means that they had been prepared with the same portland cement, same fine and coarse aggregates and the same consistency, and that they would act as "reference" for all previous ones. In such a way the dosage was found: E, in this case, that was the same as the "model" as for the amount of fine and coarse aggregates, but not as for the amount of the portland cement used which this time was 360 kg/m3 instead of 400kg/m3 SF content 40 kg/m3 and water 144 l/m3Al humo de sílice(HSE) o microsílice, se le relaciona, principalmente, con la preparación de hormigones de alta resistencia. Esta peculiar característica, ha justificado su utilización -junto a cemento portland (un I-42,5/SR,MR) y un aditivo superfluidificante- en la preparación de un hormigón cuyo valor de resistencia mecánica a compresión a edades iniciales (5 a 10 horas, solamente) fuera superior a 40 kp/cm2, en lugar de prepararlo con dicho cemento portland y un acelerador de fraguado o dosificación "patrón”. Las técnicas experimentales utilizadas para alcanzar dicho objetivo han sido: la energía de ultrasonido y una prensa para la rotura de probetas de 30x15 cm, de 200 t de carga máxima. Mediante la primera de las técnicas, el sistema de tanteo y en tan sólo 25 días, se logró preparar hasta un total de 13 dosificaciones diferentes, las cuales fueron comparadas con dicha dosificación "patrón" y otras dos que no poseían ni acelerador de fraguado, ni HSE; es decir, que habían sido preparadas con el mismo cemento portland, los mismos áridos gruesos y finos y la misma consistencia plástica, las cuales actuarían como "referencia " de todas las anteriores. De esta manera se logró la dosificación buscada, la E, en este caso, que fue la misma que la "patrón" en cuanto a la cantidad de áridos-gruesos y finos(arena), que no, en cambio, en cuanto a la cantidad de cemento portland utilizado, la cual pasaría a ser de 360 kg/m3 en lugar de 400 kg/m3 de HSE, que fue de 40 kg/m3 y de agua de amasado, que fue de 144 l/m3

    Pre-evaluación DIT de la resistencia frente a la succión del viento de kits de revestimiento de fachada ventilada con bandejas de paneles composite de aluminio

    Get PDF
    The pre-assessment DIT of innovative building kits will facilitate the posterior issuing of a Technical Agrément throughout a preliminary but reliable assessment of fitness for use based on their critical performances. For cladding kits based on horizontal stiffened cassettes made of ACP, one of them is the resistance to wind loads. But there is no specific method available yet. It has been analysed its safety in the field of assurance against meteorological risks and regulations. It has been established as hypothesis, that kits would resist winds of speed up to 96 km/h with no breakage neither significant permanent deflections. Different cassettes were tested on a real-scale rig built up with different cassettes. Results lead to conclude that these kits will be safe against wind suction if they resist 2,4 kPa without breakages, and accumulated instantaneous and permanent deflections are restricted respectively to values up to L/30 and L/300, where L is the span between supports.La pre-evaluación DIT de sistemas constructivos innovadores facilitará la posterior emisión de un DIT mediante una evaluación preliminar pero fiable de aquellas prestaciones críticas relativas a su idoneidad de empleo. Para los kits de revestimiento de fachada ventilada con bandejas horizontales procedentes de PCA rigidizadas por su trasdós, una de éstas es la resistencia frente al viento. Pero no hay un método específico. Se analizó su seguridad desde los ámbitos del aseguramiento frente al riesgo meteorológico y de la normativa. Se estableció como hipótesis que resistirían sin roturas ni deformaciones permanentes significativas, valores de succión de viento de hasta 96 km/h. Se ensayaron diferentes bandejas en una maqueta a escala real. Se concluye que estos kits serán seguros si resisten un valor de 2,4 kPa sin rotura, y se limitan las deformaciones acumuladas instantáneas y residuales a valores máximos respectivos de L/30 y L/300, siendo L la distancia entre apoyos

    Modelo matemático del comportamiento mecánico en flexión del cartón-yeso

    Get PDF
    The article proposes a mathematical model which predicts the bearing load capacity of gypsum plasterboard sheets in bending tests, based on the geometric dimensions and the mechanical properties of the constituent materials. Thus obtained values are compared with those proposed by various European and American Standards for the minimum bearing load capacity as well as with experimental laboratory measurements. In both cases the results obtained reached an excellent level of agreement.Se presenta un modelo matemático que predice la carga de rotura de las placas de cartón-yeso en ensayos a flexotracción, a partir del conocimiento de sus dimensiones geométricas y de las propiedades mecánicas de los materiales componentes. Los valores así obtenidos se comparan con los que proponen diversas normas europeas y americanas para la carga de rotura mínima, así como con medidas experimentales en laboratorio, obteniéndose en ambos casos un acuerdo excelente

    Sex differences in treatment strategy for coronary artery aneurysms: Insights from the international Coronary Artery Aneurysm Registry

    Get PDF
    INTRODUCTION: Sex disparities exist in coronary artery disease (CAD) in terms of risk profile, clinical management and outcome. It is unclear if differences are also present in coronary aneurysms, a rare variant of CAD. METHODS: Patients were selected from the international Coronary Artery Aneurysm Registry (CAAR; ClinicalTrials.gov: NCT02563626), and differences between groups were analysed according to sex. The CAAR database is a prospective multicentre registry of 1565 patients with coronary aneurysms (336 females). Kaplan-Meier method was used for event-free survival analysis for death, major adverse cardiac events (MACE: composite endpoint of death, heart failure and acute coronary syndrome) and bleeding. RESULTS: Female patients were older, were more often hypertensive and less frequently smoker. They were treated conservatively more often compared to male patients and received significantly less frequently aspirin (92% vs 88%, p = 0.002) or dual antiplatelet therapy (DAPT) (67% vs 58%, p = 0.001) at discharge. Median DAPT duration was also shorter (3 vs 9 months, p = 0.001). Kaplan-Meier analysis revealed no sex differences in death, MACE or bleeding during a median follow-up duration of 37 months, although male patients did experience acute coronary syndrome (ACS) more often during follow-up (15% vs 10%, p = 0.015). CONCLUSIONS: These CAAR findings showed a comparable high-risk cardiovascular risk profile for both sexes. Female patients were treated conservatively more often and received DAPT less often at discharge, with a shorter DAPT duration. ACS was more prevalent among male patients; however, overall clinical outcome was not different between male and female patients during follow-up