6 research outputs found

    A stability-indicating high performance liquid chromatographic (HPLC) assay for the simultaneous determination of atorvastatin and amlodipine in commercial tablets

    Get PDF
    A simple, rapid, precise and accurate isocratic reversed-phase stability-indicating HPLC method was developed and validated for the simultaneous determination of atorvastatin (AT) and amlodipine (AM) in commercial tablets. The method has shown adequate separation for AM, AT from their associated main impurities and their degradation products. Separation was achieved on a Perfectsil® Target ODS-3, 5 μm, 250 mm × 4.6 mm i.d. column using a mobile phase consisting of acetonitrile–0.025 M NaH2PO4 buffer (pH 4.5) (55:45, v/v) at a flow rate of 1 ml/min and UV detection at 237 nm. The drugs were subjected to oxidation, hydrolysis, photolysis and heat to apply stress conditions. The linearity of the proposed method was investigated in the range of 2–30 μg/ml (r = 0.9994) for AT and 1–20 μg/ml (r = 0.9993) for AM. The limits of detection were 0.65 μg/ml and 0.35 μg/ml for AT and AM, respectively. The limits of quantitation were 2 μg/ml and 1 μg/ml for AT and AM, respectively. Degradation products produced as a result of stress studies did not interfere with the detection of AT and AM and the assay can thus be considered stability-indicating

    A stability-indicating high performance liquid chromatographic (HPLC) assay for the simultaneous determination of atorvastatin and amlodipine in commercial tablets

    Get PDF
    A simple, rapid, precise and accurate isocratic reversed-phase stability-indicating HPLC method was developed and validated for the simultaneous determination of atorvastatin (AT) and amlodipine (AM) in commercial tablets. The method has shown adequate separation for AM, AT from their associated main impurities and their degradation products. Separation was achieved on a Perfectsil® Target ODS-3, 5 μm, 250 mm × 4.6 mm i.d. column using a mobile phase consisting of acetonitrile–0.025 M NaH2PO4 buffer (pH 4.5) (55:45, v/v) at a flow rate of 1 ml/min and UV detection at 237 nm. The drugs were subjected to oxidation, hydrolysis, photolysis and heat to apply stress conditions. The linearity of the proposed method was investigated in the range of 2–30 μg/ml (r = 0.9994) for AT and 1–20 μg/ml (r = 0.9993) for AM. The limits of detection were 0.65 μg/ml and 0.35 μg/ml for AT and AM, respectively. The limits of quantitation were 2 μg/ml and 1 μg/ml for AT and AM, respectively. Degradation products produced as a result of stress studies did not interfere with the detection of AT and AM and the assay can thus be considered stability-indicating

    Nanomaterial-based electrochemical sensing of neurological drugs and neurotransmitters

    No full text

    Electrochemical Sensors and Biosensors

    No full text

    Pharmaceuticals and Related Drugs

    No full text
    corecore