169 research outputs found

    Unsupervised Monitoring System for Predictive Maintenance of High Voltage Apparatus

    Get PDF
    The online monitoring of a high voltage apparatus is a crucial aspect for a predictive maintenanceprogram. Partialdischarges(PDs)phenomenaaffecttheinsulationsystemofanelectrical machine and\u2014in the long term\u2014can lead to a breakdown, with a consequent, signi\ufb01cant economic loss; wind turbines provide an excellent example. Embedded solutions are therefore required to monitor the insulation status. The paper presents an online system that adopts unsupervised methodologies for assessing the condition of the monitored machine in real time. The monitoring process does not rely on any prior knowledge about the apparatus; nonetheless, the method can identify the relevant drifts in the machine status. In addition, the system is speci\ufb01cally designed to run on low-cost embedded devices

    Confinement from new global defect structures

    Full text link
    We investigate confinement from new global defect structures in three spatial dimensions. The global defects arise in models described by a single real scalar field, governed by special scalar potentials. They appear as electrically, magnetically or dyonically charged structures. We show that they induce confinement, when they are solutions of effective QCD-like field theories in which the vacua are regarded as color dielectric media with an anti-screening property. As expected, in three spatial dimensions the monopole-like global defects generate the Coulomb potential as part of several confining potentials.Comment: RevTex4, 7 pages, 1 figure. Version to appear in Eur. Phys. J.

    Evaluation of Xpert MTB/RIF Versus AFB Smear and Culture to Identify Pulmonary Tuberculosis in Patients With Suspected Tuberculosis From Low and Higher Prevalence Settings

    Get PDF
    Background. The Xpert MTB/RIF (Xpert) assay is a rapid nucleic acid amplification test widely used in settings of high tuberculosis prevalence to detect tuberculosis as well as rpoB mutations associated with rifampin resistance. Data are needed on the diagnostic performance of Xpert in lower-prevalence settings to inform appropriate use for both tuberculosis detection and the need for respiratory isolation. Methods. Xpert was compared to 2 sputum samples, each evaluated with acid-fast bacilli (AFB) smear and mycobacterial culture using liquid and solid culture media, from participants with suspected pulmonary tuberculosis from the United States, Brazil, and South Africa. Results. Of 992 participants enrolled with evaluable results, 22% had culture-confirmed tuberculosis. In 638 (64%) US participants, 1 Xpert result demonstrated sensitivity of 85.2% (96.7% in participants with AFB smear-positive [AFB+] sputum, 59.3% with AFB smear-negative [AFB–] sputum), specificity of 99.2%, negative predictive value (NPV) of 97.6%, and positive predictive value of 94.9%. Results did not differ between higher- and low-prevalence settings. A second Xpert assay increased overall sensitivity to 91.1% (100% if AFB+, 71.4% if AFB–), with specificity of 98.9%. In US participants, a single negative Xpert result predicted the absence of AFB+/culture-positive tuberculosis with an NPV of 99.7%; NPV of 2 Xpert assays was 100%, suggesting a role in removing patients from airborne infection isolation. Xpert detected tuberculosis DNA and mutations associated with rifampin resistance in 5 of 7 participants with rifampin-resistant, culture-positive tuberculosis. Specificity for rifampin resistance was 99.5% and NPV was 98.9%. Conclusions. In the United States, Xpert testing performed comparably to 2 higher-tuberculosis-prevalence settings. These data support the use of Xpert in the initial evaluation of tuberculosis suspects and in algorithms assessing need for respiratory isolation

    Two-pion Bose-Einstein correlations in central Pb-Pb collisions at sNN\sqrt{s_{\rm NN}} = 2.76 TeV

    Get PDF
    The first measurement of two-pion Bose-Einstein correlations in central Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm NN}} = 2.76 TeV at the Large Hadron Collider is presented. We observe a growing trend with energy now not only for the longitudinal and the outward but also for the sideward pion source radius. The pion homogeneity volume and the decoupling time are significantly larger than those measured at RHIC.Comment: 17 pages, 5 captioned figures, 1 table, authors from page 12, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/388

    Suppression of charged particle production at large transverse momentum in central Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm NN}} = 2.76 TeV

    Get PDF
    Inclusive transverse momentum spectra of primary charged particles in Pb-Pb collisions at sNN\sqrt{s_{_{\rm NN}}} = 2.76 TeV have been measured by the ALICE Collaboration at the LHC. The data are presented for central and peripheral collisions, corresponding to 0-5% and 70-80% of the hadronic Pb-Pb cross section. The measured charged particle spectra in ∣η∣<0.8|\eta|<0.8 and 0.3<pT<200.3 < p_T < 20 GeV/cc are compared to the expectation in pp collisions at the same sNN\sqrt{s_{\rm NN}}, scaled by the number of underlying nucleon-nucleon collisions. The comparison is expressed in terms of the nuclear modification factor RAAR_{\rm AA}. The result indicates only weak medium effects (RAA≈R_{\rm AA} \approx 0.7) in peripheral collisions. In central collisions, RAAR_{\rm AA} reaches a minimum of about 0.14 at pT=6p_{\rm T}=6-7GeV/cc and increases significantly at larger pTp_{\rm T}. The measured suppression of high-pTp_{\rm T} particles is stronger than that observed at lower collision energies, indicating that a very dense medium is formed in central Pb-Pb collisions at the LHC.Comment: 15 pages, 5 captioned figures, 3 tables, authors from page 10, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/98

    Investments in the Human Capital of the Socially Disadvantaged Children – Effects on Redistribution

    Full text link

    Planck intermediate results X : Physics of the hot gas in the Coma cluster

    Get PDF
    Peer reviewe

    Planck Intermediate Results II: Comparison of Sunyaev–Zeldovich measurements from Planck and from the Arcminute Microkelvin Imager for 11 galaxy clusters

    Get PDF
    A comparison is presented of Sunyaev–Zeldovich measurements for 11 galaxy clusters as obtained by Planck and by the ground-based interferom- eter, the Arcminute Microkelvin Imager. Assuming a universal spherically-symmetric Generalised Navarro, Frenk & White (GNFW) model for the cluster gas pressure profile, we jointly constrain the integrated Compton-Y parameter (Y500) and the scale radius (ξ500) of each cluster. Our resulting constraints in the Y500 − ξ500 2D parameter space derived from the two instruments overlap significantly for eight of the clusters, although, overall, there is a tendency for AMI to find the Sunyaev–Zeldovich signal to be smaller in angular size and fainter than Planck. Significant discrepancies exist for the three remaining clusters in the sample, namely A1413, A1914, and the newly-discovered Planck cluster PLCKESZ G139.59+24.18. The robustness of the analysis of both the Planck and AMI data is demonstrated through the use of detailed simulations, which also discount confusion from residual point (radio) sources and from diffuse astrophysical foregrounds as possible explanations for the discrepancies found. For a subset of our cluster sample, we have investigated the dependence of our results on the assumed pressure profile by repeating the analysis adopting the best-fitting GNFW profile shape which best matches X-ray observations. Adopting the best-fitting profile shape from the X-ray data does not, in general, resolve the discrepancies found in this subset of five clusters. Though based on a small sample, our results suggest that the adopted GNFW model may not be sufficiently flexible to describe clusters universally

    Physics of the HL-LHC, and Perspectives at the HE-LHC

    Get PDF

    Measurement of D+- and D0 production in deep inelastic scattering using a lifetime tag at HERA

    Get PDF
    The production of D-+/-- and D-0-mesons has been measured with the ZEUS detector at HERA using an integrated luminosity of 133.6 pb(-1). The measurements cover the kinematic range 5 < Q(2) < 1000 GeV2, 0.02 < y < 0.7, 1.5 < p(T)(D) < 15 GeV and |eta(D)| < 1.6. Combinatorial background to the D-meson signals is reduced by using the ZEUS microvertex detector to reconstruct displaced secondary vertices. Production cross sections are compared with the predictions of next-to-leading-order QCD, which is found to describe the data well. Measurements are extrapolated to the full kinematic phase space in order to obtain the open-charm contribution, F-2(c (c) over bar), to the proton structure function, F-2
    • 

    corecore