4,107 research outputs found

    A review of registry research from 2020

    Get PDF

    Optical tweezers: wideband microrheology

    Full text link
    Microrheology is a branch of rheology having the same principles as conventional bulk rheology, but working on micron length scales and micro-litre volumes. Optical tweezers have been successfully used with Newtonian fluids for rheological purposes such as determining fluid viscosity. Conversely, when optical tweezers are used to measure the viscoelastic properties of complex fluids the results are either limited to the material's high-frequency response, discarding important information related to the low-frequency behavior, or they are supplemented by low-frequency measurements performed with different techniques, often without presenting an overlapping region of clear agreement between the sets of results. We present a simple experimental procedure to perform microrheological measurements over the widest frequency range possible with optical tweezers. A generalised Langevin equation is used to relate the frequency-dependent moduli of the complex fluid to the time-dependent trajectory of a probe particle as it flips between two optical traps that alternately switch on and off.Comment: 13 pages, 6 figures, submitted to Special Issue of the Journal of Optic

    Nature Of Transition Circumstellar Disks. I. The Ophiuchus Molecular Cloud

    Get PDF
    We have obtained millimeter-wavelength photometry, high-resolution optical spectroscopy, and adaptive optics near-infrared imaging for a sample of 26 Spitzer-selected transition circumstellar disks. All of our targets are located in the Ophiuchus molecular cloud (d similar to 125 pc) and have spectral energy distributions (SEDs) suggesting the presence of inner opacity holes. We use these ground-based data to estimate the disk mass, multiplicity, and accretion rate for each object in our sample in order to investigate the mechanisms potentially responsible for their inner holes. We find that transition disks are a heterogeneous group of objects, with disk masses ranging from <0.6 to 40 M(JUP) and accretion rates ranging from <10(-11) to 10(-7) M(circle dot) yr(-1), but most tend to have much lower masses and accretion rates than "full disks" (i.e., disks without opacity holes). Eight of our targets have stellar companions: six of them are binaries and the other two are triple systems. In four cases, the stellar companions are close enough to suspect they are responsible for the inferred inner holes. We find that nine of our 26 targets have low disk mass (<2.5 M(JUP)) and negligible accretion (<10(-11) M(circle dot) yr(-1)), and are thus consistent with photoevaporating (or photoevaporated) disks. Four of these nine non-accreting objects have fractional disk luminosities <10(-3) and could already be in a debris disk stage. Seventeen of our transition disks are accreting. Thirteen of these accreting objects are consistent with grain growth. The remaining four accreting objects have SEDs suggesting the presence of sharp inner holes, and thus are excellent candidates for harboring giant planets.NASA 1224608, 1230782, 1230779, 1407FONDECYT 1061199Basal CATA PFB 06/09ALMA FUND 31070021ALMA-Conicyt FUND 31060010National Science Foundation AST0-808144Spitzer Space Telescope Legacy Science ProgramAstronom

    Measuring storage and loss moduli using optical tweezers: broadband microrheology

    Full text link
    We present an experimental procedure to perform broadband microrheological measurements with optical tweezers. A generalised Langevin equation is adopted to relate the time-dependent trajectory of a particle in an imposed flow to the frequency-dependent moduli of the complex fluid. This procedure allows us to measure the material linear viscoelastic properties across the widest frequency range achievable with optical tweezers.Comment: 5 pages, 3 figure

    A Novel, Contactless, Portable “Spot-Check” Device Accurately Measures Respiratory Rate

    Get PDF
    Respiratory rate (RR) is an important vital sign used in the assessment of acutely ill patients. It is also used as to predict serious deterioration in a patient's clinical condition. Convenient electronic devices exist for measurement of pulse, blood pressure, oxygen saturation and temperature. Although devices which measure RR exist, none has entered everyday clinical practice. We developed a contactless portable respiratory rate monitor (CPRM) and evaluated the agreement in respiratory rate measurements between existing methods and our new device. The CPRM uses thermal anemometry to measure breath signals during inspiration and expiration. RR data were collected from 52 healthy adult volunteers using respiratory inductance plethysmography (RIP) bands (established contact method), visual counting of chest movements (established non-contact method) and the CPRM (new method), simultaneously. Two differently shaped funnel attachments were evaluated for each volunteer. Data showed good agreement between measurements from the CPRM and the gold standard RIP, with intra-class correlation coefficient (ICC): 0.836, mean difference 0.46 and 95% limits of agreement of -5.90 to 6.83. When separate air inlet funnels of the CPRM were analysed, stronger agreement was seen with an elliptical air inlet; ICC 0.908, mean difference 0.37 with 95% limits of agreement -4.35 to 5.08. A contactless device for accurately and quickly measuring respiratory rate will be an important triage tool in the clinical assessment of patients. More testing is needed to explore the reasons for outlying measurements and to evaluate in the clinical setting

    Mitomycin C versus 5-Fluorouracil for wound healing in glaucoma surgery.

    Get PDF
    BACKGROUND: Raised intraocular pressure is a risk factor for glaucoma. One treatment option is glaucoma drainage surgery (trabeculectomy). Antimetabolites are used during surgery to reduce postoperative scarring during wound healing. Two agents in common use are mitomycin C (MMC) and 5-Fluorouracil (5-FU). OBJECTIVES: To assess the effects of MMC compared to 5-FU as an antimetabolite adjunct in trabeculectomy surgery. SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2015 Issue 9), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2015), EMBASE (January 1980 to October 2015), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to October 2015), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 2 October 2015. SELECTION CRITERIA: We included randomised controlled trials where wound healing had been modified with MMC compared to 5-FU. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials and collected data. The primary outcome was failure of a functioning trabeculectomy one year after surgery. Secondary outcomes included mean intraocular pressure at one year. We considered three subgroups: high risk of trabeculectomy failure (people with previous glaucoma surgery, extracapsular cataract surgery, African origin and people with secondary glaucoma or congenital glaucoma); medium risk of trabeculectomy failure (people undergoing trabeculectomy with extracapsular cataract surgery) and low risk of trabeculectomy failure (people who have received no previous surgical eye intervention). MAIN RESULTS: We identified 11 trials that enrolled 687 eyes of 679 participants. The studies were conducted in the United States, Europe, Asia and Africa. Five studies enrolled participants at low risk of trabeculectomy failure, five studies enrolled participants at high risk of failure, and one study enrolled people with both high and low risk of failure. None of the included trials enrolled participants with combined trabeculectomy/cataract surgery.We considered one study to be at low risk of bias in all domains, six studies to be at high risk of bias in one or more domains, and the remaining four studies to be at an unclear risk of bias in all domains.The risk of failure of trabeculectomy at one year after surgery was less in those participants who received MMC compared to those who received 5-FU, however the confidence intervals were wide and are compatible with no effect (risk ratio (RR) 0.54, 95% confidence interval (CI) 0.30 to 1.00; studies = 11; I(2) = 40%). There was no evidence for any difference between groups at high and low risk of failure (test for subgroup differences P = 0.69).On average, people treated with MMC had lower intraocular pressure at one year (mean difference (MD) -3.05 mmHg, 95% CI -4.60 to -1.50), but the studies were inconsistent (I(2) = 52%). The size of the effect was greater in the high-risk group (MD -4.18 mmHg, 95% CI -6.73 to -1.64) compared to the low-risk group (MD -1.72 mmHg, 95% CI -3.28 to -0.16), but again the test for interaction was not statistically significant (P = 0.11).Similar proportions of eyes treated with MMC lost 2 or more lines of visual acuity one year after surgery compared to 5-FU, but the confidence intervals were wide (RR 1.05, 95% CI 0.54 to 2.06).Adverse events occurred relatively rarely, and estimates of effect were generally imprecise. There was some evidence for less epitheliopathy in the MMC group (RR 0.23, 95% CI 0.11 to 0.47) and less hyphaema in the MMC group (RR 0.62, 95% CI 0.42 to 0.91).None of the studies reported quality of life.Overall, we graded the quality of the evidence as low largely because of risk of bias in the included studies and imprecision in the estimate of effect. AUTHORS' CONCLUSIONS: We found low-quality evidence that MMC may be more effective in achieving long-term lower intraocular pressure than 5-FU. Further comparative research on MMC and 5-FU is needed to enhance reliability and validity of the results shown in this review. Furthermore, the development of new agents that control postoperative scar tissue formation without side effects would be valuable and is justified by the results of this review

    Nutrient contamination from non-point sources: Dissolved nitrate and ammonium in surface and subsurface waters at EKU Meadowbrook Farm, Madison County, Kentucky

    Get PDF
    Agricultural activities often contaminate watersheds with excess nutrients leading to poor water quality and eutrophication. We assayed dissolved nutrient levels in surface and subsurface waters of Eastern Kentucky University’s Meadowbrook Farm in order to assess levels of dissolved nutrients leaving its farmland and draining into the Muddy Creek watershed. The Farm raises both crops and livestock so that nutrient sources include fertilizer and manure. We sampled springs, runoff, and subsurface pipe drainage as well as Muddy Creek on six days from May to August 2016 under a variety of weather conditions. Using established, standard colorimetric methods, we measured nitrate (NO3-; cadmium reduction method) and ammonium (NH4+; sodium hypochlorate method) via spectrophotometry with a precision and accuracy of ~0.1 mg/L. Nitrate was the dominant dissolved nitrogen species whereas ammonium was often absent in water samples. Nitrate levels were typically \u3c2 mg/L N- N- NO3 with the largest values between 7.0 and 14.3 mg/L. Springs and some runoff samples had higher nitrate values. Ammonium generally ranged between 0.0 and 0.5 mg/L N- NH4 with concentration spikes between 2.0 and 4.3 mg/L, but from no consistent source. Dissolved nitrogen concentration values responded to rainfall. Generally, nitrate concentrations increased more than ammonium concentrations during wetter periods. Spring samples maintained higher nitrogen concentrations regardless of different rainfall conditions. Lastly, nitrate contamination was significantly lower than composite national values from streams draining agricultural lands, whereas ammonium was about equal to the median national average. Median nitrate concentration was ~1.8 mg/L N- NO3 compared to the national value of ~2.8 mg/L, whereas the value for pristine streams is 0.24 mg/L N- NO3 (Dubrovsky et al., 2010). Median ammonium values from both data sets are ~0.1 mg/L N- NH4; the national value from pristine streams is ~0.025 mg/L N

    Prejudice Against Immigrants Symptomizes a Larger Syndrome, Is Strongly Diminished by Socioeconomic Development, and the UK Is Not an Outlier: Insights From the WVS, EVS, and EQLS Surveys

    Get PDF
    Public attitudes toward immigrants in the UK, especially prejudice against them, form a strong theme in retrospective media postmortems emphasizing the uniqueness of Brexit, yet similarly hostile public opinion on immigrants forms a recurrent theme in populist politics in many European Union nations. Indeed, if UK residents are not uniquely hostile, then the UK's exit from the EU may be only the first symptom of proliferating conflicts over immigration that will plague EU nations in future years. A well-established symptom (or consequence) of prejudice—aversion to outgroups as a neighbors—shows that prejudice against immigrants, other races, Muslims, Hindus, Jews, and Gypsies are all relatively low in the UK. This is as expected from the general decline of prejudice and social distance with socioeconomic development, demonstrated here in broad perspective across many countries. Indeed, UK residents are about as prejudiced against each of these ethno-religious outgroups as are their peers in other advanced EU and English-speaking nations, and much less prejudiced than their peers in less prosperous countries. Confirmatory factor analysis supports the view that a single latent ethno-religious prejudice generates all these specific prejudices, so it is not specific experiences with any one of these groups, nor their specific attributes, that are the wellspring of this deep-seated underlying prejudice. Replication using other measures of prejudice and another cross-national dataset confirms these findings. Data are from the pooled World and European Values Surveys (over 450,000 individuals, 300 surveys, and 100 nations for this analysis) and from the well-known European Quality of Life surveys. Analysis is by descriptive, multilevel (random intercept, fixed effects), and structural equation methods

    Nutrient contamination from non-point sources: Dissolved nitrate and ammonium in surface and subsurface waters at EKU Meadowbrook Farm, Madison County, Kentucky

    Get PDF
    Agricultural activities often contaminate watersheds with excess nutrients leading to poor water quality and eutrophication. We assayed dissolved nutrient levels in surface and subsurface waters of Eastern Kentucky University’s Meadowbrook Farm in order to assess levels of dissolved nutrients leaving its farmland and draining into the Muddy Creek watershed. The Farm raises both crops and livestock so that nutrient sources include fertilizer and manure. We sampled springs, runoff, and subsurface pipe drainage as well as Muddy Creek on six days from May to August 2016 under a variety of weather conditions. Using established, standard colorimetric methods, we measured nitrate (NO3-; cadmium reduction method) and ammonium (NH4+; sodium hypochlorate method) via spectrophotometry with a precision and accuracy of ~0.1 mg/L. Nitrate was the dominant dissolved nitrogen species whereas ammonium was often absent in water samples. Nitrate levels were typically \u3c2 mg/L N- N- NO3 with the largest values between 7.0 and 14.3 mg/L. Springs and some runoff samples had higher nitrate values. Ammonium generally ranged between 0.0 and 0.5 mg/L N- NH4 with concentration spikes between 2.0 and 4.3 mg/L, but from no consistent source. Dissolved nitrogen concentration values responded to rainfall. Generally, nitrate concentrations increased more than ammonium concentrations during wetter periods. Spring samples maintained higher nitrogen concentrations regardless of different rainfall conditions. Lastly, nitrate contamination was significantly lower than composite national values from streams draining agricultural lands, whereas ammonium was about equal to the median national average. Median nitrate concentration was ~1.8 mg/L N- NO3 compared to the national value of ~2.8 mg/L, whereas the value for pristine streams is 0.24 mg/L N- NO3 (Dubrovsky et al., 2010). Median ammonium values from both data sets are ~0.1 mg/L N- NH4; the national value from pristine streams is ~0.025 mg/L N
    • …
    corecore