Impact of European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) guidelines on the use of contrast agents in liver ultrasound
The introduction of microbubble contrast agents and the development of contrast-specific techniques have opened new prospects in liver ultrasound. Over the past few years several reports have shown that contrast ultrasound can substantially improve detection and characterization of focal liver lesions with respect to baseline studies. The advent of second-generation agents and low mechanical index real-time scanning techniques has been instrumental in improving the easiness and the reproducibility of the examination. With the publication of the guidelines for the use of contrast agents in liver ultrasound by the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB), contrast ultrasound enters into clinical practice. The guidelines define the indications and recommendations for the use of contrast ultrasound in focal liver lesion detection, characterization, and follow-up after tumor ablation procedures. We discuss the impact of EFSUMB guidelines on diagnostic protocols currently adopted in liver imaging
The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children
Purpose: The aim of this study was to investigate the relationship between optic nerve sheath diameter (ONSD) measurement and invasively measured intracranial pressure (ICP) in children.
Methods: ONSD measurement was performed prior to invasive measurement of ICP. The mean binocular ONSD measurement was compared to the ICP reading. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), pulse rate, temperature, respiratory rate and end tidal carbon dioxide (ETCO2) level were recorded at the time of ONSD measurement. Diagnostic accuracy analysis was performed at various ICP thresholds and repeatability, intra- and inter-observer variability, correlation between measurements in different imaging planes as well the relationship over the entire patient cohort were examined in part I of this study.
Results: Data from 174 patients were analysed. Repeatability and intra-observer variability were excellent (α = 0.97–0.99). Testing for inter-observer variability revealed good correlation (r = 0.89, p < 0.001). Imaging in the sagittal plane demonstrated a slightly better correlation with ICP (r = 0.66, p < 0.001). The ONSD measurement with the best diagnostic accuracy for detecting an ICP ≥ 20 mmHg over the entire patient cohort was 5.5 mm, sensitivity 93.2 %, specificity 74 % and odds ratio (OR) of 39.3.
Conclusion: Transorbital ultrasound measurement of the OSND is a reliable and reproducible technique, demonstrating a good relationship with ICP and high diagnostic accuracy for detecting raised ICP