30 research outputs found

    Ten-year follow-up of a total knee prosthesis combining multi-radius, ultra-congruency, posterior-stabilization and mobile-bearing insert shows long-lasting clinically relevant improvements in pain, stiffness, function and stability.

    Get PDF
    There is a paucity of data available on total knee prostheses combining dual-radius, ultra-congruency, posterior-stabilization and mobile-bearing insert. This prospective cohort study aimed to assess the clinical evolution of the FIRST <sup>®</sup> prosthesis (Symbios Orthopédie, Yverdon, CH), the earliest prosthesis with this particular design. It was hypothesized that the primary outcomes, evaluating pain, stiffness, function and stability, would improve following arthroplasty and remain improved during the follow-up period of 10 years. All patients programmed for a total knee arthroplasty using a FIRST <sup>®</sup> prosthesis at our university hospital between 2006 and 2008 were invited to participate. Study knees were evaluated pre-operatively as well as one, five and ten years post-operatively. Patients filled out questionnaires at each evaluation point and had a radiographic assessment at the five-year and ten-year follow-ups. Primary outcomes were the total, pain, stiffness and function measures of the Western Ontario and McMaster Universities Osteoarthritis questionnaire (WOMAC) and the knee and function measures of the Knee Society Score (KSS). Friedman and Wilcoxon's rank-sum tests were used to compare measures across time points. Hundred and twenty four prostheses were included (baseline demographics: 69.9 ± 8.3 years old, 28.1 ± 4.3 kg/m <sup>2</sup> , 54% male) and 68 could be followed during ten years. Five prostheses underwent a revision. All other prostheses lost at follow-up were lost for reasons unrelated to the prosthesis. All primary measures reported statistically and clinically significant improvements between baseline and the three follow-up evaluations. Statistically significant improvements at the three follow-up evaluations were also observed for most secondary measures. There was no implant loosening. At ten-year follow-up, radiolucent lines were observed in 2.9% femoral implants and 1.5% tibial implants. The positive results observed in all domains of assessment and the small revision rate demonstrated an effective functioning of the FIRST <sup>®</sup> prosthesis during the ten-year follow-up period. The results, globally similar to those previously published for other prosthesis designs, encourage the development of assistive methods to select the most appropriate designs on an individual basis. IV, prospective cohort study

    Tibio-talar arthrodesis with long anterograde nail after complex open fracture-dislocation of the ankle : P17

    No full text
    Introduction: Posttraumatic painful osteoarthritis of the ankle joint after fracture-dislocation often has to be treated with arthrodesis. In the presence of major soft tissue lesions and important bone loss the technique to achieve arthrodesis has to be well chosen in order to prevent hardware failure, infection of bulky implants or non-union. Methods: We present the case of a 53 year-old biker suffering of a fracture-dislocation of the ankle associated with a mayor degloving injury of the heel. After initial immobilization of the lesion by external fixation in Spain the patient was transferred to our hospital for further treatment. The degloving injury of the heel with MRSA infection was initially treated by repeated débridement, changing of the configuration of the Ex Fix and antibiotic therapy with favourable outcome. Because of the bony lesions reconstruction of the ankle-joint was juged not to be an option and arthrodesis was planned. Due to bad soft-tissue situation standard open fixtion with plate and/or screws was not wanted but an option for intramedullary nailing was taken. However the use of a standard retrograde arthrodesis nail comes with two problems: 1) Risk of infection of the heel-part of the calaneus/nail in an unstable soft tissue situation with protruding nail. And 2) talo-calcaneal arthrodesis of an initially healthy subtalar joint. Given the situation of an unstable plantar/heel flap it was decided to perform anklearthrodesis by means of an anterograde nail with static fixation in the talus and in the proximal tibia. Results:This operation was performed with minimal opening at the ankle-site in order to remove the remaining cartilage and improve direct bone to bone contact. Arthrodesis was achieved by means of an anterograde T2 Stryker tibial nail.One year after the anterograde nailing the patient walks without pain for up to 4 hours with a heel of good quality and arthrodesis is achieved. Conclusion: Tibiotalar arthrodesis in the presence of mayor soft tissue lesions and bone loss can be successfully achieved with antegrade nailing

    [Mechanical complications of total shoulder inverted prosthesis]

    No full text
    Our series of inverted prosthesis included 5 patients with a mean age of 73 +/- 6 years. In 4 cases, the implant was performed as a surgical revision. The follow up was 81 +/- 15 months. Three shoulders were pain free whereas two caused a dull pain after a free interval due to mechanical complications. The mean active elevation was 72degrees while external rotation was -2degrees. The adjusted Constant score passed from 32 to 60. In case of complications, the score dropped to 32. Mechanical complications were important with in one case, an unscrening of the glenosphere and in two cases, a loosening of the glenoid prosthesis. This last and major complication occurred 6 years after surgery and was promoted by the occurrence of a progressive bone erosion in the scapula. This gap represented an attempt to accomodate the medial part of the humeral prosthesis under the scapula when the arm is at rest or in adduction. The concept of an inverted prosthesis is attractive and this implant remains one of the options in cuff-tear arthropathy. Our results were not as good as those reported by others but most of ours patients had been already operated before. The occurrence of an osseous gap on pilar of scapula may lead to failure of this prothesis. This gap remains a threath as it can progress and as such warrants a design alteration of the prosthesis

    Complications mécaniques de la prothèse totale inversée de l'épaule

    No full text
    [Mechanical complications of total shoulder inverted prosthesis]. Our series of inverted prosthesis included 5 patients with a mean age of 73 +/- 6 years. In 4 cases, the implant was performed as a surgical revision. The follow up was 81 +/- 15 months. Three shoulders were pain free whereas two caused a dull pain after a free interval due to mechanical complications. The mean active elevation was 72 degrees while external rotation was - 2 degrees. The adjusted Constant score passed from 32 to 60. In case of complications, the score dropped to 32. Mechanical complications were important with in one case, an unscrening of the glenosphere and in two cases, a loosening of the glenoid prosthesis. This last and major complication occurred 6 years after surgery and was promoted by the occurrence of a progressive bone erosion in the scapula. This gap represented an attempt to accomodate the medial part of the humeral prosthesis under the scapula when the arm is at rest or in adduction. The concept of an inverted prosthesis is attractive and this implant remains one of the options in cuff-tear arthropathy. Our results were not as good as those reported by others but most of ours patients had been already operated before. The occurrence of an osseous gap on pilar of scapula may lead to failure of this prosthesis. This gap remains a threath as it can progress and as such warrants a design alteration of the prosthesis

    Production and Properties of a New Porous Bearing

    No full text

    A randomised controlled clinical trial and gait analysis of fixed- and mobile-bearing total knee replacements with a five-year follow-up.

    No full text
    This study compared the outcome of total knee replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses during the first post-operative year and at five years' follow-up, using gait parameters as a new objective measure. This double-blind randomised controlled clinical trial included 55 patients with mobile-bearing (n = 26) and fixed-bearing (n = 29) prostheses of the same design, evaluated pre-operatively and post-operatively at six weeks, three months, six months, one year and five years. Each participant undertook two walking trials of 30 m and completed the EuroQol questionnaire, Western Ontario and McMaster Universities osteoarthritis index, Knee Society score, and visual analogue scales for pain and stiffness. Gait analysis was performed using five miniature angular rate sensors mounted on the trunk (sacrum), each thigh and calf. The study population was divided into two groups according to age (≤ 70 years versus > 70 years). Improvements in most gait parameters at five years' follow-up were greater for fixed-bearing TKRs in older patients (> 70 years), and greater for mobile-bearing TKRs in younger patients (≤ 70 years). These findings should be confirmed by an extended age controlled study, as the ideal choice of prosthesis might depend on the age of the patient at the time of surgery

    Fixed bearing for TKR provides better results for individuals aged 70 and above

    Get PDF
    55 patients, scheduled to undergo total knee replacement, were randomized to receive either fixed or mobile-bearings. The results from a 5 year follow-up indicated that elderly patients (>70 years of age) with fixed bearings had better improvements in gait parameters in comparison to those with mobile bearings. These results was in fact reversed for patients less than 70 years of age, as they performed best with mobile bearings

    Objective results at 1 year of a new ultracongruent postero-stabilized total knee arthroplasty

    No full text
    Introduction: A new ultra congruent, postero-stabilized total knee arthroplasty (TKA) with a mobile bearing, the FIRST knee prosthesis (Free Insert in Rotation Stabilized in Translation, Symbios SA), was designed and expected to significantly reduce polyethylene wear, to improve the range of motion and the overall stability of the knee while ensuring a physiological ligament balance. Gait analysis has proven to give really objective outcome parameters after lower limb surgery. The goal of our study was to compare the subjective and really objective results of this new TKA with two other widespread models of TKA. Methods: A clinical prospective monocentric cohort study of 100 consecutive patients (47-88 yrs) undergoing a FIRST TKA for primary osteoarthritis is currently being done. Pre- and post-operative follow-ups (6 weeks, 4 months and 1 year) were done with well-recognized subjective evaluations (EQ-5D and WOMAC scores) and semi-objective questionnaires (KSS score and radiography evaluation) as well as with a really objective evaluation using gait parameters from 6 walking trials, performed at different speeds (slow, normal and fast) with an ambulatory gait analysis system (Physilog®, BioAGM CH). The outcomes of the first 32 new TKA after one year of follow-up were compared to the results after 1 year of a randomized controlled clinical trial comparing 29 NexGen® postero-stabilized TKA (Zimmer Inc) with a fixed bearing and 26 NexGen® TKA with a mobile bearing using the same methods. Results: Subjective and semi-objective results were similar for the three types of TKA. As for the really objective parameters, the gait cycle time of the FIRST TKA was statistically significantly shorter at normal speed of walk, as well as double-support periods, as compared to both standard models. The extension (in terms of range of motion when walking) of the operated knee was significantly improved for all three types of walk in favour of the FIRST TKAs compared to both NexGen TKAs. The normal walking speed was significantly higher with faster swing speed and stride lengths for the new TKA. Significantly better coordination scores were observed at normal walking speed for the FIRST TKA as compared to the fixed-bearing TKAs. Conclusion: The FIRST TKAs showed statistically significantly better objective outcomes in terms of gait after one year of follow-up with similar subjective and semi-objective results in comparison with widespread TKA designs. These encouraging short-terms results will have to be confirmed at a 5 years follow-up of the FIRST TKAs
    corecore