8 research outputs found

    Algorithm for multi-curve-fitting with shared parameters and a possible application in evoked compound action potential measurements

    Get PDF
    BACKGROUND: Experimental results are commonly fitted by determining parameter values of suitable mathematical expressions. In case a relation exists between different data sets, the accuracy of the parameters obtained can be increased by incorporating this relationship in the fitting process instead of fitting the recordings separately. METHODS: An algorithm to fit multiple measured curves simultaneously was developed. The method accounts for parameters that are shared by some curves. It can be applied to either linear or nonlinear equations. Simulated noisy "measurement results" were created to compare the introduced method to the "straight forward" way of fitting the curves separately. RESULTS: The analysis of the simulated measurements confirm, that the introduced method yields more accurate parameters compared to the ones gained by fitting the measurements separately. Therefore it needs more computer time. As an example, the new fitting algorithm is applied to the measurements of the evoked compound action potentials (ECAP) of the auditory nerve: This leads to promising ideas to reduce artefacts generated by the measuring process. CONCLUSION: The introduced fitting algorithm uses the relationship between multiple measurement results to increase the accuracy of the parameters. Its application in the field of ECAP measurements is promising and should be further investigated

    Ultra-Wideband Transceivers for Cochlear Implants

    No full text
    <p/> <p>Ultra-wideband (UWB) radio offers low power consumption, low power spectral density, high immunity against interference, and other benefits, not only for consumer electronics, but also for medical devices. A cochlear implant (CI) is an electronic hearing apparatus, requiring a wireless link through human tissue. In this paper we propose an UWB link for a data rate of <inline-formula><graphic file="1687-6180-2005-647310-i1.gif"/></inline-formula> Mbps and a propagation distance up to 500 mm. Transmitters with step recovery diode and transistor pulse generators are proposed. Two types of antennas and their filter characteristics in the UWB spectrum will be discussed. An ultra-low-power back tunnel diode receiver prototype is described and compared with conventional detector receivers.</p

    Multimodal Treatment of Malignant Pleural Mesothelioma: Real-World Experience with 112 Patients

    No full text
    Malignant pleural mesothelioma (MPM) is a rare pleural cancer associated with asbestos exposure. According to current evidence, the combination of chemotherapy, surgery and radiotherapy improves patients’ survival. However, the optimal sequence and weighting of the respective treatment modalities is unclear. In anticipation of the upcoming results of the MARS-2 trial, we sought to determine the relative impact of the respective treatment modalities on complications and overall survival in our own consecutive institutional series of 112 patients. Fifty-seven patients (51%) underwent multimodality therapy with curative intent, while 55 patients (49%) were treated with palliative intent. The median overall survival (OS) of the entire cohort was 16.9 months (95% CI: 13.4–20.4) after diagnosis; 5-year survival was 29% for patients who underwent lung-preserving surgery. In univariate analysis, surgical treatment (p p p p = 0.02) and the absence of arterial hypertension (p = 0.034) were found to be prognostic factors for OS. In multivariate analysis, epithelioid subtype was associated with a survival benefit, whereas the occurrence of complications was associated with worse OS. Multimodality therapy including surgery significantly prolonged the OS of MPM patients compared with multimodal therapy without surgery
    corecore