22 research outputs found

    Septic coxitis after an intramuscular injection in a young adult treated by two-steps total hip arthroplasty: a case report

    Get PDF
    Introduction: Septic arthritis of the hip is a rare condition in adults and its treatment depends on symptoms duration: early onset of infection can be treated with open or arthroscopic debridement, while more aggressive surgery is required when articular damage takes place such as articular resection or total hip replacement (THA). Presentation of case: We report a case of a 30 year old man affect by septic arthritis of the hip after an intramuscular injection of diclofenac successfully treated with a two-steps THA. Discussion: In literature there aren't many cases of septic arthritis of the hip developed after intramuscular injections. Early onset of infection can be treated with an accurate articular debridement, while chronic conditions are traditionally treated by resection arthroplasty. However resection arhtroplasty gives to the patients a significant leg length discrepancy and, especially in young adults, a two-steps surgery with the implant of THA can lead to good results, as reported in recent case series published. Conclusion: In our experience two-stage total hip arthroplasty proved to be a reliable solution for septic arthritis of the hip and may be used in patient with severe joint damage. Furthermore we want underline importance of correct anamnesis to make quickly the right diagnosis and provide the right treatment of septic arthritis of the hip also in difficult clinical cases

    Evaluation of orthopaedic fast-track surgery from 2009 to 2013 in an Italian hospital

    Get PDF
    Each year millions of patients are treated for joint pain with total joint arthroplasty, and the numbers are expected to rise. Total knee arthroplasty (TKA) has an integral role in the treatment of severe knee joint diseases including osteoarthritis and rheumatoid arthritis and long-term results for pain relief and functional improvement have been excellent.The aim of this study was to evaluate whether the application of the Fast-Track method has reduced the LOS during a period of 5 years, while taking care of the patients outcome and the readmission rate in our Department

    Use of a Plasma-Sprayed Titanium-Hydroxyapatite Femoral Stem in Hip Arthroplasty in Patients Older than 70 Years. Is Cementless Fixation a Reliable Option in the Elderly?

    Get PDF
    Background: Although cementless implants are increasing in popularity, the use of cementless femoral stems for total hip arthroplasty (THA) and hip hemiarthroplasty (HH) in elderly patients remains controversial. The aim of this study was to report the outcomes of a cementless stem used in a large multicentric cohort of elderly patients receiving elective THA and HH for displaced femoral neck fracture. Methods: A total of 293 patients (301 hips) aged 70 years or older (mean age, 78 years; range, 70–93) who received the same cementless plasma-sprayed porous titanium–hydroxyapatite stem were retrospectively evaluated after primary THA and HH to investigate stem survival, complications, and clinical and radiographic results. Results: Cumulative stem survival was 98.5% (95% CI, 96.4–99.4%; 91 hips at risks) with revision due to any reason as the end-point at 10-year follow-up (mean 8.6 years, range 4–12). No stem was revised due to aseptic loosening. The mean Forgotten Joint Score was 98.7. Radiographically, the implants showed complete osseointegration, with slight stress-shieling signs in less than 10% of the hips. Conclusion: The use of cementless stems was proven to be a reliable and versatile option even in elderly patients for elective THA and HH for femoral neck fracture

    Early experience about Anteversa® plate for lateral femur fractures

    Get PDF
    Introduction. The hip fractures appear to be a real epidemic problem, especially in the western world, due primarily to higher average age. The social and economical impact is considerable with a continue social and health costs up-rising. The female-male ratio is approximately 8:1. Purpose. The purpose of this report is to present a system of osteosynthesis for fractures of the lateral femoral neck. This system is a plate developed by INTRAUMA O'nil®, 3-hole plate with an 130° angle of valgus and 7° of anteversion. Materials and methods. At the I Orthopedic Department at the University of Pisa from January 2009 to February 2012 were treated 52 fractures of the femur neck side with this system. All patients undergone to a clinical and X-ray evaluation according to the AO classification: 14 31-A1, 7 31-A2, 4 31-A3. Results. The mean follow-up was 10 months, in all cases we did not have cut-outs with a TAD average of 23 mm. Conclusions. This system offers the possibility to perform surgery quickly with low risk of cut-out thanks to 7° of anteversion. Ensures optimal fixation to the femoral shaft and an equitable distribution of forces, eliminating the risk of breakage of the implant and loosening of the screw

    Bilateral shoulder pain after a generalized tonic-clonic seizure: case report of an acute undiagnosed bilateral fracture of proximal humerus

    No full text
    Bilateral shoulder fracture is a rare event and convulsive epileptic seizure is one of the most common causes. Detailed physical and neurovascular examination are important but shoulder’s antero- posterior and axillary radiographs are essential to reveal a possible fracture and/or dislocation. Diagnosis could be difficult and often missed because of the importance given to patient’s neurological issue. We present a case of a young man with an acute undiagnosed bilateral fracture of proximal humerus as complication of a generalized tonic-clonic seizure. After seven days we performed a surgical procedure of bilateral reduction and osteosynthesis with angular stability plate and screws

    HYDROXYAPATITE IN TOTAL HIP ARTHROPLASTY. OUR EXPERIENCE WITH A TITANIUM AND HYDROXYAPATITE DOUBLE-COATED CEMENTLESS STEM

    No full text
    Introduc on: Total hip arthroplasty (THA) could fail due to many factors and asep c loosening is one of the most common. In order to achieve an e ec ve osseointegra on contact porous bearing surface were developed. Objec vies: Aim of this retrospec ve study was to evaluate clinical and ra- diological mid-term outcomes of a porous tanium alloy/Hydroxyapa te double coa ng manufactured cementless femoral stem and to demonstrate the possibility to use this stem in di erent kind of femoral canals. Methods: Between January 2008 and December 2012, 182 consecu ve primary total hip arthroplas es (THAs) were performed using a porous - tanium alloy/Hydroxyapa te double coa ng manufactured cementless fem- oral stem. 182 pa ents were examined and 136 were female (74.7%) and 46 male (25.2%); average age was 72 years old (26-92). Harris Hip Scores (HHS) and Womac Scores were collected. All X-Ray images were analyzed in order to demonstrate stem survival rate and subsidence. Results: HHS was good or excellent in 85% and mean WOMAC score was 97.5 (73.4-100). No cases of early/late infec on or periprosthe c fracture were no ced, with an excellent implant survival rate (100%) in a mean period of 40 months (24-84). 5 cases presented acute implant disloca on, 2 due to wrong cup posi oning in a dysplas c acetabulum and 3 a er ground level fall. Dorr classi ca on of femoral geometry was used: 51 type A bone, 53 Type B and 78 Type C. Stem subsidence over 2 mm was considered as a risk factor of future implant loosening and was evidenced in 3 female pa ents with type C. Conclusions: This data reported an excellent implant survival rate in a mid- term period with a rate of 1,64% of subsidence. Radiological absence of pedestal has been accepted as sign of no excessive stress transmission to distal cortex due to its tapered diaphyseal region.This double coa ng can be considered a valid choice with an excellent medi- um-term survival and encouraging subsidence results

    Synthetic Bone Grafting in Aseptic Loosening of Acetabular Cup: Good Clinical and Radiological Outcomes in Contained Bone Defects at Medium-Term Follow Up

    No full text
    Restoring bone loss is one of the major challenges when facing hip revision surgery. To eliminate the risk of disease transmission and antigenicity of allografts and donor-morbidity of autografts, the use of synthetic bioceramics has become popular in the last decade. Our study investigated the effectiveness of impaction bone grafting (IBG) of contained acetabular defects (Paprosky 2 and 3a) using a porous ceramic-based hydroxyapatite bone substitute (Engipore, provided by Finceramica Faenza S.p.A., Faenza, Italy) mixed with a low percentage of autologous bone (obtained from reaming when available). We retrospectively assessed 36 patients who underwent acetabular revision using IBG using a porous ceramic-based hydroxyapatite bone substitute with cementless implants with a mean follow-up of 4.4 years. We evaluated, at regular intervals, patients clinically (using the Hip Harris Score and Oxford Score) and radiologically to evaluate the rate of incorporation of the graft, the presence of radiolucent lines or migrations of the cup. Clinical scores significantly improved (WOMAC improved from 49.7–67.30, and the HSS from 56–89). The rate of implants’ survival was 100% at our medium follow-up (4.4 years). We reported five cases of minor migration of the cup, and radiolucent lines were visible in seven patients at the last-follow up. The graft was well-incorporated in all patients. The results presented in this study suggest the HA bone substitute is an effective and safe bone graft when facing hip revision surgery; thus, longer follow-up studies are required

    THE USE OF BALLOON CATHETER INTO THE INFRARENAL AORTA FOR PREVENTION OF MASSIVE HEMORRHAGE DURING REVISION HIP REPLACEMENT AT HIGH RISK: A CASE REPORT

    No full text
    Introduc on: Intraopera ve bleeding is one of the most dangerous compli- ca ons of revision surgery of the hip. In this study we present our experience and the method used to prevent a massive hemorrhage during revision sur- gery of hip replacement. Materials and methods: In May 2014 in our department we have performed revision surgery of hip implants in a pa ent with asep c loosening of the cup that had taken con guity for a distance of 2.5 cm with the right external iliac artery. During surgery with the help of an interven onal radiologist using ultrasound guided catheteriza on of the le common femoral artery it was posi oned a valved introducer with apex in infrarenal abdominal aorta. It was later made the revision surgery for hip replacement. Results: The opera on has been carried out and there has not been any bleeding during the extrac on of the cup. The nal angiographic control sup- ports the absence of vascular lesions. Conclusions: The use of this protec on has allowed the team to perform the surgery with less anxiety and stress. In fact, the radiologist in case of bleeding was ready to in ate the ball and create a transient ischemia for the me required to repair the artery and the conclusion of the interven on. Our opinion is that this is a safe and reproducible method to u lize in selected cases at risk of major bleeding

    The difference in activity of daily living (ADL) and mortality in patients aged over 80 years with femoral neck fracture treated with hemiarthroplasty or osteosynthesis at 2 years of follow-up

    No full text
    Hip fractures are one of the major causes of morbidity and mortality in the elderly and outcomes following hip fracture have been the focus of several studies over recent decades. Among all types of fall-related injuries, hip fractures cause the greatest number of deaths, lead to severe health problems and reduce quality of life. Improving the outcome of hip fracture surgery has thus become one of the main areas of interest for orthopaedic surgeons. The aim of this study was to compare the difference in activity of daily living (ADL) and mortality between patients aged over 80 years with hip fracture treated with osteosynthesis versus prosthesis at 2 years of follow-up
    corecore