19 research outputs found

    Discordance between estimated and measured changes in plasma volume among patients with acute heart failure

    Get PDF
    Aims: In acute heart failure (AHF), changes of venous haemoglobin (Hb) concentrations, haematocrit (Hct), and estimated plasma volume (ePV) have been proposed as surrogates of decongestion. These estimates are based on the theoretical assumptions that changes of Hb concentrations and Hct are driven by the intravascular volume status and that the intravascular Hb pool remains stable. The objective of this study was to assess the relationship of changes of measured plasma volume (mPV) with changes of Hb, Hct, and ePV in AHF. Methods and results: We studied 36 AHF patients, who received two sequential assessments of mPV, measured red cell volume (mRCV) and measured total blood volume (mTBV) (48 h apart), during the course of diuretic therapy using a novel visible fluorescent injectate (VFI) technique based on the indicator dilution principle. Changes of ePV were calculated based on the Kaplan-Hakim or Strauss formula. AHF patients receiving diuretics (median intravenous furosemide equivalent 160 mg/48 h) displayed a wide range of changes of mPV (-25.4% to +37.0%). Changes in mPV were not significantly correlated with changes of Hb concentration [Pearson's r (r) = -0.241, P = 0.157], Hct (r = -0.307, P = 0.069), ePV(Kaplan-Hakim) (r = 0.228, P = 0.182), or ePV(strauss) (r = 0.237, P = 0.163). In contrast to theoretical assumptions, changes of mTBV were poorly correlated with changes of Hb concentrations and some patients displayed unanticipated variability of mRCV, suggesting an unstable intravascular red cell pool. Conclusions: Changes of Hb or Hct were not reflective of directly measured changes of intravascular volume status in AHF patients. Basing clinical assessment of decongestion on changes of Hb or Hct may misguide clinical decision-making on an individual patient level

    Serum creatinine and cystatin C‐based estimates of glomerular filtration rate are misleading in acute heart failure

    Get PDF
    Aims: We aimed to test whether the endogenous filtration markers serum creatinine or cystatin C and equation-based estimates of glomerular filtration rate (GFR) based on these markers appropriately reflect changes of measured GFR in patients with acute heart failure. Methods: In this prospective cohort study of 50 hospitalized acute heart failure patients undergoing decongestive therapy, we applied an intravenous visible fluorescent injectate (VFI), consisting of a low molecular weight component to measure GFR and a high molecular weight component to correct for measured plasma volume. Thirty-eight patients had two sequential GFR measurements 48 h apart. The co-primary endpoints of the study were safety of VFI and plasma stability of the high molecular weight component. A key secondary endpoint was to compare changes in measured GFR (mGFR) to changes of serum creatinine, cystatin C and estimated GFR. Results: VFI-based GFR measurements were safe and consistent with plasma stability of the high molecular weight component and glomerular filtration of the low molecular weight component. Filtration marker-based point estimates of GFR, when compared with mGFR, provided only moderate correlation (Pearson's r, range 0.80-0.88, depending on equation used), precision (r(2), range 0.65-0.78) and accuracy (56%-74% of estimates scored within 30% of mGFR). Correlations of 48-h changes GFR estimates and changes of mGFR were significant (P 15% decrease in mGFR. Conclusions: In patients hospitalized for acute heart failure, serum creatinine- and cystatin C-based predictions performed poorly in detecting actual changes of GFR. These data challenge current clinical strategies to evaluate dynamics of kidney function in acute heart failure

    Moving in the anthropocene: global reductions in terrestrial mammalian movements

    Get PDF
    Animal movement is fundamental for ecosystem functioning and species survival, yet the effects of the anthropogenic footprint on animal movements have not been estimated across species. Using a unique GPS-tracking database of 803 individuals across 57 species, we found that movements of mammals in areas with a comparatively high human footprint were on average one-half to one-third the extent of their movements in areas with a low human footprint. We attribute this reduction to behavioral changes of individual animals and to the exclusion of species with long-range movements from areas with higher human impact. Global loss of vagility alters a key ecological trait of animals that affects not only population persistence but also ecosystem processes such as predator-prey interactions, nutrient cycling, and disease transmission

    Socializing One Health: an innovative strategy to investigate social and behavioral risks of emerging viral threats

    Get PDF
    In an effort to strengthen global capacity to prevent, detect, and control infectious diseases in animals and people, the United States Agency for International Development’s (USAID) Emerging Pandemic Threats (EPT) PREDICT project funded development of regional, national, and local One Health capacities for early disease detection, rapid response, disease control, and risk reduction. From the outset, the EPT approach was inclusive of social science research methods designed to understand the contexts and behaviors of communities living and working at human-animal-environment interfaces considered high-risk for virus emergence. Using qualitative and quantitative approaches, PREDICT behavioral research aimed to identify and assess a range of socio-cultural behaviors that could be influential in zoonotic disease emergence, amplification, and transmission. This broad approach to behavioral risk characterization enabled us to identify and characterize human activities that could be linked to the transmission dynamics of new and emerging viruses. This paper provides a discussion of implementation of a social science approach within a zoonotic surveillance framework. We conducted in-depth ethnographic interviews and focus groups to better understand the individual- and community-level knowledge, attitudes, and practices that potentially put participants at risk for zoonotic disease transmission from the animals they live and work with, across 6 interface domains. When we asked highly-exposed individuals (ie. bushmeat hunters, wildlife or guano farmers) about the risk they perceived in their occupational activities, most did not perceive it to be risky, whether because it was normalized by years (or generations) of doing such an activity, or due to lack of information about potential risks. Integrating the social sciences allows investigations of the specific human activities that are hypothesized to drive disease emergence, amplification, and transmission, in order to better substantiate behavioral disease drivers, along with the social dimensions of infection and transmission dynamics. Understanding these dynamics is critical to achieving health security--the protection from threats to health-- which requires investments in both collective and individual health security. Involving behavioral sciences into zoonotic disease surveillance allowed us to push toward fuller community integration and engagement and toward dialogue and implementation of recommendations for disease prevention and improved health security

    Discordance between estimated and measured changes in plasma volume among patients with acute heart failure

    Full text link
    Aims: In acute heart failure (AHF), changes of venous haemoglobin (Hb) concentrations, haematocrit (Hct), and estimated plasma volume (ePV) have been proposed as surrogates of decongestion. These estimates are based on the theoretical assumptions that changes of Hb concentrations and Hct are driven by the intravascular volume status and that the intravascular Hb pool remains stable. The objective of this study was to assess the relationship of changes of measured plasma volume (mPV) with changes of Hb, Hct, and ePV in AHF. Methods and results: We studied 36 AHF patients, who received two sequential assessments of mPV, measured red cell volume (mRCV) and measured total blood volume (mTBV) (48 h apart), during the course of diuretic therapy using a novel visible fluorescent injectate (VFI) technique based on the indicator dilution principle. Changes of ePV were calculated based on the Kaplan-Hakim or Strauss formula. AHF patients receiving diuretics (median intravenous furosemide equivalent 160 mg/48 h) displayed a wide range of changes of mPV (-25.4% to +37.0%). Changes in mPV were not significantly correlated with changes of Hb concentration [Pearson's r (r) = -0.241, P = 0.157], Hct (r = -0.307, P = 0.069), ePVKaplan-Hakim (r = 0.228, P = 0.182), or ePVStrauss (r = 0.237, P = 0.163). In contrast to theoretical assumptions, changes of mTBV were poorly correlated with changes of Hb concentrations and some patients displayed unanticipated variability of mRCV, suggesting an unstable intravascular red cell pool. Conclusions: Changes of Hb or Hct were not reflective of directly measured changes of intravascular volume status in AHF patients. Basing clinical assessment of decongestion on changes of Hb or Hct may misguide clinical decision-making on an individual patient level

    Discordance between estimated and measured changes in plasma volume among patients with acute heart failure

    Get PDF
    Aims: In acute heart failure (AHF), changes of venous haemoglobin (Hb) concentrations, haematocrit (Hct), and estimated plasma volume (ePV) have been proposed as surrogates of decongestion. These estimates are based on the theoretical assumptions that changes of Hb concentrations and Hct are driven by the intravascular volume status and that the intravascular Hb pool remains stable. The objective of this study was to assess the relationship of changes of measured plasma volume (mPV) with changes of Hb, Hct, and ePV in AHF. Methods and results: We studied 36 AHF patients, who received two sequential assessments of mPV, measured red cell volume (mRCV) and measured total blood volume (mTBV) (48 h apart), during the course of diuretic therapy using a novel visible fluorescent injectate (VFI) technique based on the indicator dilution principle. Changes of ePV were calculated based on the Kaplan-Hakim or Strauss formula. AHF patients receiving diuretics (median intravenous furosemide equivalent 160 mg/48 h) displayed a wide range of changes of mPV (-25.4% to +37.0%). Changes in mPV were not significantly correlated with changes of Hb concentration [Pearson\u27s r (r) = -0.241, P = 0.157], Hct (r = -0.307, P = 0.069), ePVKaplan-Hakim (r = 0.228, P = 0.182), or ePVStrauss (r = 0.237, P = 0.163). In contrast to theoretical assumptions, changes of mTBV were poorly correlated with changes of Hb concentrations and some patients displayed unanticipated variability of mRCV, suggesting an unstable intravascular red cell pool. Conclusions: Changes of Hb or Hct were not reflective of directly measured changes of intravascular volume status in AHF patients. Basing clinical assessment of decongestion on changes of Hb or Hct may misguide clinical decision-making on an individual patient level

    Serum creatinine and cystatin C-based estimates of glomerular filtration rate are misleading in acute heart failure

    Full text link
    AIMS: We aimed to test whether the endogenous filtration markers serum creatinine or cystatin C and equation-based estimates of glomerular filtration rate (GFR) based on these markers appropriately reflect changes of measured GFR in patients with acute heart failure. METHODS: In this prospective cohort study of 50 hospitalized acute heart failure patients undergoing decongestive therapy, we applied an intravenous visible fluorescent injectate (VFI), consisting of a low molecular weight component to measure GFR and a high molecular weight component to correct for measured plasma volume. Thirty-eight patients had two sequential GFR measurements 48 h apart. The co-primary endpoints of the study were safety of VFI and plasma stability of the high molecular weight component. A key secondary endpoint was to compare changes in measured GFR (mGFR) to changes of serum creatinine, cystatin C and estimated GFR. RESULTS: VFI-based GFR measurements were safe and consistent with plasma stability of the high molecular weight component and glomerular filtration of the low molecular weight component. Filtration marker-based point estimates of GFR, when compared with mGFR, provided only moderate correlation (Pearson\u27s r, range 0.80-0.88, depending on equation used), precision (r2 , range 0.65-0.78) and accuracy (56%-74% of estimates scored within 30% of mGFR). Correlations of 48-h changes GFR estimates and changes of mGFR were significant (P \u3c 0.05) but weak (Pearson\u27s r, range 0.35-0.39). Observed decreases of eGFR by more than 15% had a low sensitivity (range 38%-46%, depending on equation used) in detecting true worsening mGFR, defined by a \u3e15% decrease in mGFR. CONCLUSIONS: In patients hospitalized for acute heart failure, serum creatinine- and cystatin C-based predictions performed poorly in detecting actual changes of GFR. These data challenge current clinical strategies to evaluate dynamics of kidney function in acute heart failure
    corecore