6 research outputs found

    Neurotrophin gene augmentation by electrotransfer to improve cochlear implant hearing outcomes

    Get PDF
    This Review outlines the development of DNA-based therapeutics for treatment of hearing loss, and in particular, considers the potential to utilize the properties of recombinant neurotrophins to improve cochlear auditory (spiral ganglion) neuron survival and repair. This potential to reduce spiral ganglion neuron death and indeed re-grow the auditory nerve fibres has been the subject of considerable pre-clinical evaluation over decades with the view of improving the neural interface with cochlear implants. This provides the context for discussion about the development of a novel means of using cochlear implant electrode arrays for gene electrotransfer. Mesenchymal cells which line the cochlear perilymphatic compartment can be selectively transfected with (naked) plasmid DNA using array - based gene electrotransfer, termed ‘close-field electroporation’. This technology is able to drive expression of brain derived neurotrophic factor (BDNF) in the deafened guinea pig model, causing re-growth of the spiral ganglion peripheral neurites towards the mesenchymla cells, and hence into close proximity with cochlear implant electrodes within scala tympani. This was associated with functional enhancement of the cochlear implant neural interface (lower neural recruitment thresholds and expanded dynamic range, measured using electrically - evoked auditory brainstem responses). The basis for the efficiency of close-field electroporation arises from the compression of the electric field in proximity to the ganged cochlear implant electrodes. The regions close to the array with highest field strength corresponded closely to the distribution of bioreporter cells (adherent human embryonic kidney (HEK293)) expressing green fluorescent reporter protein (GFP) following gene electrotransfer. The optimization of the gene electrotransfer parameters using this cell-based model correlated closely with in vitro and in vivo cochlear gene delivery outcomes. The migration of the cochlear implant electrode array-based gene electrotransfer platform towards a clinical trial for neurotrophin-based enhancement of cochlear implants is supported by availability of a novel regulatory compliant mini-plasmid DNA backbone (pFAR4; plasmid Free of Antibiotic Resistance v.4) which could be used to package a ‘humanized’ neurotrophin expression cassette. A reporter cassette packaged into pFAR4 produced prominent GFP expression in the guinea pig basal turn perilymphatic scalae. More broadly, close-field gene electrotransfer may lend itself to a spectrum of potential DNA therapeutics applications benefitting from titratable, localised, delivery of naked DNA, for gene augmentation, targeted gene regulation, or gene substitution strategies

    Subthreshold Electrical Stimulation for Controlling Protein-Mediated Impedance Increases in Platinum Cochlear Electrode

    Full text link
    Objective: This study evaluated subthreshold biphasic stimulation pulses as a strategy to stabilize electrode impedance via control of protein adsorption. Following implantation, cochlear electrodes undergo impedance fluctuations thought to be caused by protein adsorption and/or inflammatory responses. Impedance increases can impact device power consumption, safe charge injection limits, and long-term stability of electrodes. Methods: Protein-mediated changes in polarization impedance (Zp) were measured by voltage transient responses to biphasic current pulses and electrochemical impedance spectroscopy, with and without protein solutions. Four subthreshold stimulation regimes were studied to assess their effects on protein adsorption and impedance; (1) symmetric charge-balanced pulses delivered continuously, (2) at 10% duty cycle, (3) at 1% duty cycle, and (4) an asymmetric charge balanced pulse delivered continuously with a cathodic phase twice as long as the anodic phase. Results: The Zp of electrodes incubated in protein solutions without stimulation for 2 h increased by between ∼28% and ∼55%. Subthreshold stimulation reduced the rate at which impedance increased following exposure to all protein solutions. Decreases in Zp were dependent on the type of protein solution and the stimulation regime. Subthreshold stimulation pulses were more effective when delivered continuously compared to 1% and 10% duty cycles. Conclusion: These results support the potential of subthreshold stimulation pulses to mitigate protein-mediated increase in impedance. Significance: This research highlights the potential of clinically translatable stimulation pulses to mitigate perilymph protein adsorption on cochlear electrodes, a key phenomenon precursor of the inflammatory response

    Development and performance of a biomimetic artificial perilymph for in vitro testing of medical devices

    No full text
    Objective. Cochlear implants interface with the fluid in the cochlea called perilymph. The volume of this fluid present in human and animal model cochlea is prohibitively low for isolation for in vitro studies. Thus, there is a need for an artificial perilymph that reflects the complexity of this fluid in terms of competitive protein adsorption. Approach. This study established a biomimetic artificial perilymph (BAP) comprising serum albumin, immunoglobulin G, transferrin, inter-alpha-trypsin inhibitor, apolipoprotein A1 and complement C3 to represent the major components of human perilymph. Adsorption of the BAP components to platinum was analysed. Main results. It was established that this six component BAP provided competitive and complex adsorption behaviours consistent with biologically derived complex fluids. Additionally, adsorption of the BAP components to platinum cochlear electrodes resulted in a change in polarisation impedance consistent with that observed for the cochlear device in vivo. Significance. This study established a BAP fluid suitable for furthering the understanding of the implant environment for electroactive devices that interface with the biological environment

    Comparing perilymph proteomes across species

    Full text link
    Objectives/Hypothesis: Biological components of perilymph affect the electrical performance of cochlear implants. Understanding the perilymph composition of common animal models will improve the understanding of this impact and improve the interpretation of results from animal studies and how it relates to humans. Study Design: Analysis and comparison of the proteomes of human, guinea pig, and cat perilymph. Methods: Multiple perilymph samples from both guinea pigs and cats were analysed via liquid chromatography with tandem mass spectrometry. Proteins were identified using the Mascot database. Human data were obtained from a published dataset. Proteins identified were refined to form a proteome for each species. Results: Over 200 different proteins were found per species. There were 81, 39, and 64 proteins in the final human, guinea pig, and cat proteomes, respectively. Twenty-one proteins were common to all three species. Fifty-two percent of the cat proteome was found in the human proteome, and 31% of the guinea pig was common to human. The cat proteome had similar complexity to the human proteome in three protein classes, whereas the guinea pig had a similar complexity in two. The presence of albumin was significantly higher in human perilymph than in the other two species. Immunoglobulins were more abundant in the human than in the cat proteome. Conclusions: Perilymph proteomes were compared across three species. The degree of crossover of proteins of both guinea pig and cat with human indicate that these animals suitable models for the human cochlea, albeit the cat perilymph is a closer match. Level of Evidence: NA. Laryngoscope, 128:E47–E52, 2018

    Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS

    No full text
    Cochlear implants operate within a bony channel of the cochlea, bathed in a fluid known as the perilymph. The perilymph is a complex fluid containing ions and proteins, which are known to actively interact with metallic electrodes. To improve our understanding of how cochlear implant performance varies in preclinical in vivo studies in comparison to human trials and patient outcomes, the protein composition (or perilymph proteome) is needed. Samples of perilymph were gathered from feline and Guinea pig subjects and analyzed using liquid chromatography with tandem mass spectrometry (LC-MS/MS) to produce proteomes and compare against the recently published human proteome. Over 64% of the proteins in the Guinea pig proteome were found to be common to the human proteome. The proportions of apolipoproteins, enzymes and immunoglobulins showed little variation between the two proteomes, with other classes showing similarity. This establishes a good basis for comparison of results. The results for the feline profile showed less similarity with the human proteome and would not provide a quality comparison. This work highlights the suitability of the Guinea pig to model the biological environment of the human cochlear and the need to carefully select models of the biological environment of a cochlear implant to more adequately translate in vitro and in vivo studies to the clinic
    corecore