18 research outputs found

    Results from the WHO external quality assessment for the respiratory syncytial virus pilot, 2016-17

    Get PDF
    BACKGROUND : External quality assessments (EQAs) for the molecular detection of respiratory syncytial virus (RSV) are necessary to ensure the provision of reliable and accurate results. One of the objectives of the pilot of the World Health Organization (WHO) Global RSV Surveillance, 2016-2017, was to evaluate and standardize RSV molecular tests used by participating countries. This paper describes the first WHO RSV EQA for the molecular detection of RSV. METHODS : The WHO implemented the pilot of Global RSV Surveillance based on the WHO Global Influenza Surveillance and Response System (GISRS) from 2016 to 2018 in 14 countries. To ensure standardization of tests, 13 participating laboratories were required to complete a 12 panel RSV EQA prepared and distributed by the Centers for Disease Control and Prevention (CDC), USA. The 14th laboratory joined the pilot late and participated in a separate EQA. Laboratories evaluated a RSV rRT-PCR assay developed by CDC and compared where applicable, other Laboratory Developed Tests (LDTs) or commercial assays already in use at their laboratories. RESULTS : Laboratories performed well using the CDC RSV rRT-PCR in comparison with LDTs and commercial assays. Using the CDC assay, 11 of 13 laboratories reported correct results. Two laboratories each reported one false-positive finding. Of the laboratories using LDTs or commercial assays, results as assessed by Ct values were 100% correct for 1/5 (20%). With corrective actions, all laboratories achieved satisfactory outputs. CONCLUSIONS : These findings indicate that reliable results can be expected from this pilot. Continued participation in EQAs for the molecular detection of RSV is recommended.The Bill and Melinda Gates Foundation, the Respiratory Viruses Branch, Division of Viral Diseases, CDC, Atlanta, and the CDC International Reagent Resource (IRR), USA.http://www.wileyonlinelibrary.com/journal/irvam2020Medical Virolog

    Inhibitory control, but not prolonged object-related experience appears to affect physical problem-solving performance of pet dogs

    Get PDF
    Human infants develop an understanding of their physical environment through playful interactions with objects. Similar processes may influence also the performance of non-human animals in physical problem-solving tasks, but to date there is little empirical data to evaluate this hypothesis. In addition or alternatively to prior experiences, inhibitory control has been suggested as a factor underlying the considerable individual differences in performance reported for many species. Here we report a study in which we manipulated the extent of object-related experience for a cohort of dogs (Canis familiaris) of the breed Border Collie over a period of 18 months, and assessed their level of inhibitory control, prior to testing them in a series of four physical problem-solving tasks. We found no evidence that differences in object-related experience explain variability in performance in these tasks. It thus appears that dogs do not transfer knowledge about physical rules from one physical problem-solving task to another, but rather approach each task as a novel problem. Our results, however, suggest that individual performance in these tasks is influenced in a complex way by the subject’s level of inhibitory control. Depending on the task, inhibitory control had a positive or a negative effect on performance and different aspects of inhibitory control turned out to be the best predictors of individual performance in the different tasks. Therefore, studying the interplay between inhibitory control and problem-solving performance will make an important contribution to our understanding of individual and species differences in physical problem-solving performance

    Evaluación del desempeño de un equipo comercial para el diagnóstico de influenza A (H1N1) en comparación con el protocolo de RT-PCR en tiempo real diseñado por los Centros de Control y Prevención de Enfermedades (CDC)

    Full text link
    Fil: Barbas, M. G. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.Fil: Gallego, S. V. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.Fil: Castro, G. M. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.Fil: Baumeister, E. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Infecciosas; Argentina.Fil: Kademian, S. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.Fil: de Leon, J. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.Fil: Cudola, A. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.At the time of influenza A (H1N1) emergency, the WHO responded with remarkable speed by releasing guidelines and a protocol for a real-time RT-PCR assay (rRT-PCR). The aim of the present study was to evaluate the performance of the “Real Time Ready Influenza A/H1N1 Detection Set” (June 2009)-Roche kit in comparison to the CDC reference rRT-PCR protocol. The overall sensitivity of the Roche assay for detection of the Inf A gene in the presence or absence of the H1 gene was 74.5 %. The sensitivity for detecting samples that were only positive for the Inf A gene (absence of the H1 gene) was 53.3 % whereas the sensitivity for H1N1-positive samples (presence of the Inf A gene and any other swine gene) was 76.4 %. The specificity of the assay was 97.1 %. A new version of the kit (November 2009) is now available, and a recent evaluation of its performance showed good sensitivity to detect pandemic H1N1 compared to other molecular assays. (ES) Durante la pandemia de influenza A (H1N1), la OMS recomendó algoritmos y protocolos de detección del virus mediante RT-PCR en tiempo real. El objetivo del presente estudio fue evaluar el desempeño del equipo que comercializa la empresa Roche, Real Time Ready Influenza A/H1N1 Detection Set (junio de 2009), en comparación con el protocolo de RT-PCR en tiempo real de los CDC. La sensibilidad global del ensayo de Roche para la detección del gen Inf A en presencia o ausencia del gen H1 fue 74,5 %. La sensibilidad para la detección de muestras positivas solo para el gen Inf A (ausencia del gen H1) fue 53,3 % y la sensibilidad para la detección de muestras positivas para H1N1 (presencia del gen Inf A y cualquier otro gen porcino) fue 76,4 %. La especificidad fue 97,1 %. Existe una nueva versión del equipo (noviembre 2009) que, según se ha descrito, presenta buena sensibilidad en comparación con otros ensayos moleculares para detectar H1N1 pandémica

    Evaluación del desempeño de un equipo comercial para el diagnóstico de influenza A (H1N1) en comparación con el protocolo de RT-PCR en tiempo real diseñado por los Centros de Control y Prevención de Enfermedades (CDC)

    Full text link
    Fil: Barbas, M. G. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.Fil: Gallego, S. V. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.Fil: Castro, G. M. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.Fil: Baumeister, E. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Infecciosas; Argentina.Fil: Kademian, S. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.Fil: de Leon, J. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.Fil: Cudola, A. Laboratorio Central del Ministerio de Salud de la Provincia de Córdoba; Argentina.At the time of influenza A (H1N1) emergency, the WHO responded with remarkable speed by releasing guidelines and a protocol for a real-time RT-PCR assay (rRT-PCR). The aim of the present study was to evaluate the performance of the “Real Time Ready Influenza A/H1N1 Detection Set” (June 2009)-Roche kit in comparison to the CDC reference rRT-PCR protocol. The overall sensitivity of the Roche assay for detection of the Inf A gene in the presence or absence of the H1 gene was 74.5 %. The sensitivity for detecting samples that were only positive for the Inf A gene (absence of the H1 gene) was 53.3 % whereas the sensitivity for H1N1-positive samples (presence of the Inf A gene and any other swine gene) was 76.4 %. The specificity of the assay was 97.1 %. A new version of the kit (November 2009) is now available, and a recent evaluation of its performance showed good sensitivity to detect pandemic H1N1 compared to other molecular assays. (ES) Durante la pandemia de influenza A (H1N1), la OMS recomendó algoritmos y protocolos de detección del virus mediante RT-PCR en tiempo real. El objetivo del presente estudio fue evaluar el desempeño del equipo que comercializa la empresa Roche, Real Time Ready Influenza A/H1N1 Detection Set (junio de 2009), en comparación con el protocolo de RT-PCR en tiempo real de los CDC. La sensibilidad global del ensayo de Roche para la detección del gen Inf A en presencia o ausencia del gen H1 fue 74,5 %. La sensibilidad para la detección de muestras positivas solo para el gen Inf A (ausencia del gen H1) fue 53,3 % y la sensibilidad para la detección de muestras positivas para H1N1 (presencia del gen Inf A y cualquier otro gen porcino) fue 76,4 %. La especificidad fue 97,1 %. Existe una nueva versión del equipo (noviembre 2009) que, según se ha descrito, presenta buena sensibilidad en comparación con otros ensayos moleculares para detectar H1N1 pandémica

    <title language="spa">Performance of a commercial assay for the diagnosis of influenza A (H1N1) infection in comparison to the Centers for Disease Control and Prevention protocol of real time RT-PCR

    Full text link
    At the time of influenza A (H1N1) emergency, the WHO responded with remarkable speed by releasing guidelines and a protocol for a real-time RT-PCR assay (rRT-PCR). The aim of the present study was to evalúate the performance of the "Real Time Ready Influenza A/H1N1 Detection Set" (June 2009)-Roche kit in comparison to the CDC reference rRT-PCR protocol. The overall sensitivity of the Roche assay for detection of the Inf A gene in the presence or absence of the H1 gene was 74.5 %. The sensitivity for detecting samples that were only positive for the Inf A gene (absence of the H1 gene) was 53.3 % whereas the sensitivity for H1N1-positive samples (presence of the Inf A gene and any other swine gene) was 76.4 %. The specificity of the assay was 97.1 %. A new version of the kit (November 2009) is now available, and a recent evaluation of its performance showed good sensitivity to detect pandemic H1N1 compared to other molecular assays.<br>Durante la pandemia de influenza A (H1N1), la OMS recomendó algoritmos y protocolos de detección del virus mediante RT-PCR en tiempo real. El objetivo del presente estudio fue evaluar el desempeño del equipo que comercializa la empresa Roche, Real Time Ready Influenza A/H1N1 Detection Set (junio de 2009), en comparación con el protocolo de RT-PCR en tiempo real de los CDC. La sensibilidad global del ensayo de Roche para la detección del gen Inf A en presencia o ausencia del gen H1 fue 74,5 %. La sensibilidad para la detección de muestras positivas solo para el gen Inf A (ausencia del gen H1) fue 53,3 % y la sensibilidad para la detección de muestras positivas para H1N1 (presencia del gen Inf A y cualquier otro gen porcino) fue 76,4 %. La especificidad fue 97,1 %. Existe una nueva versión del equipo (noviembre 2009) que, según se ha descrito, presenta buena sensibilidad en comparación con otros ensayos moleculares para detectar H1N1 pandémica

    Performance of a commercial assay for the diagnosis of influenza A (H1N1) infection in comparison to the Centers for Disease Control and Prevention protocol of real time RT-PCR

    Full text link
    At the time of influenza A (H1N1) emergency, the WHO responded with remarkable speed by releasing guidelines and a protocol for a real-time RT-PCR assay (rRT-PCR). The aim of the present study was to evalúate the performance of the "Real Time Ready Influenza A/H1N1 Detection Set" (June 2009)-Roche kit in comparison to the CDC reference rRT-PCR protocol. The overall sensitivity of the Roche assay for detection of the Inf A gene in the presence or absence of the H1 gene was 74.5 %. The sensitivity for detecting samples that were only positive for the Inf A gene (absence of the H1 gene) was 53.3 % whereas the sensitivity for H1N1-positive samples (presence of the Inf A gene and any other swine gene) was 76.4 %. The specificity of the assay was 97.1 %. A new version of the kit (November 2009) is now available, and a recent evaluation of its performance showed good sensitivity to detect pandemic H1N1 compared to other molecular assays

    Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina

    Full text link
    Our aim was to evaluate the analytical and clinical performance of the SARS-CoV-2 molecular detection kits used in Argentina. Nine real-time reverse-transcription polymerase chain reaction (RT-qPCR) and three reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assays were evaluated using the World Health Organization (WHO) recommended test as reference method. A secondary standard calibrated for the E, N and RdRp genes against the Pan American Health Organization—World Health Organization—International Standard was used to calculate the limit of detection (LoD). A panel of artificial clinical samples, 32 positive and 30 negative for SARS-CoV-2, were analyzed to estimate the kappa concordance (κ) and the diagnostic performance. Differences among the LoD values for the target genes amplified by each kit were &gt;1 log copies/reaction. The κ for the RT-qPCR kits was greater than 0.9, whereas that for the RT-LAMP assays ranged from 0.75 to 0.93. The clinical performance of RT-qPCR kits showed 100% specificity and high sensitivity, although with variations according to the gene analyzed. The E and N genes provided greater clinical sensitivity, whereas the RdRp gene increased the clinical specificity. The RT-LAMP assays revealed a variable diagnostic performance. The information provided can be useful to choose the most appropriate diagnostic test and may contribute to the establishment of a consensus in the diagnosis of SARS-CoV-2 in Argentina and the region
    corecore