72 research outputs found

    Risk of heart failure among individuals tested for Borrelia burgdorferi sensu lato antibodies, and serum Borrelia burgdorferi sensu lato seropositive individuals; a nationwide population-based, registry-based matched cohort study

    Get PDF
    BACKGROUND: Lyme borreliosis is a tick-borne disease caused by the bacterium Borrelia burgdorferi (Bb) sensu lato complex. Previous studies have suggested an association between Lyme borreliosis and heart failure, which have been suggested to be a possible manifestation of Lyme carditis. We aimed to investigate the risk of heart failure among individuals tested for serum Bb antibodies, and serum Bb seropositive individuals.METHODS: We performed a matched nationwide cohort study (Denmark, 1993-2020) and included 52,200 Bb seropositive individuals, and two age- and sex-matched comparison cohorts: 1) 104,400 Bb seronegative comparison cohort members, and 2) 261,000 population controls. We investigated the risk associated with 1) being tested for serum Bb antibodies, and 2) being Bb seropositive. Outcomes were: 1) a composite of heart failure, cardiomyopathy, and/or myocarditis diagnosis, and 2) redemption of cardiovascular medicine used for treatment of heart failure. We calculated short-term odds ratios (aOR) (within 1 month) and long-term hazard rates (aHR) (after 1 month) adjusted for age, sex, diabetes, pre-existing heart failure, and kidney disease.RESULTS: Compared with the population controls, individuals tested for Bb antibodies, regardless of the test result, had increased short-term risk of heart failure, cardiomyopathy, and myocarditis (aOR 8.3, 95 %CI: 6.7-10.2), and both increased short- and long-term risk of redemption of cardiovascular medicine (aOR 4.3, 95 %CI: 3.8-4.8, aHR 1.13, 95 % CI: 1.11-1.15). The Bb seropositive individuals had no increased short- or long-term risk of any outcome compared with Bb seronegative comparison cohort members.CONCLUSIONS: In conclusion, Bb antibody tests seemed to be performed in the diagnostic work-up of heart failure, but Bb seropositivity was not associated with heart failure.</p

    SARS-CoV-2 antibody prevalence among homeless people and shelter workers in Denmark:a nationwide cross-sectional study

    Get PDF
    BACKGROUND: People experiencing homelessness (PEH) and associated shelter workers may be at higher risk of infection with “Severe acute respiratory syndrome coronavirus 2” (SARS-CoV-2). The aim of this study was to determine the prevalence of SARS-CoV-2 among PEH and shelter workers in Denmark. DESIGN AND METHODS: In November 2020, we conducted a nationwide cross-sectional seroprevalence study among PEH and shelter workers at 21 recruitment sites in Denmark. The assessment included a point-of-care test for antibodies against SARS-CoV-2, followed by a questionnaire. The seroprevalence was compared to that of geographically matched blood donors considered as a proxy for the background population, tested using a total Ig ELISA assay. RESULTS: We included 827 participants in the study, of whom 819 provided their SARS-CoV-2 antibody results. Of those, 628 were PEH (median age 50.8 (IQR 40.9–59.1) years, 35.5% female) and 191 were shelter workers (median age 46.6 (IQR 36.1–55.0) years and 74.5% female). The overall seroprevalence was 6.7% and was similar among PEH and shelter workers (6.8% vs 6.3%, p = 0.87); and 12.2% among all participants who engaged in sex work. The overall participant seroprevalence was significantly higher than that of the background population (2.9%, p < 0.001). When combining all participants who reported sex work or were recruited at designated safe havens, we found a significantly increased risk of seropositivity compared to other participants (OR 2.23, 95%CI 1.06–4.43, p = 0.02). Seropositive and seronegative participants reported a similar presence of at least one SARS-CoV-2 associated symptom (49% and 54%, respectively). INTERPRETATIONS: The prevalence of SARS-CoV-2 antibodies was more than twice as high among PEH and associated shelter workers, compared to the background population. These results could be taken into consideration when deciding in which phase PEH are eligible for a vaccine, as part of the Danish national SARS-CoV-2 vaccination program rollout. FUNDING: TrygFonden and HelseFonden. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12889-022-13642-7

    Population-based study of diagnostic assays for Borrelia infection: comparison of purified flagella antigen assay (Ideia™, Dako Cytomation) and recombinant antigen assay (Liaison®, DiaSorin)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Testing for <it>Borrelia</it>-specific IgM and IgG-antibodies are often performed on a variety of poorly defined symptoms, and isolated IgM results are a frequent finding, which results in diagnostic uncertainty and further testing. We wanted to test the hypothesis that Borrelia-specific assays using recombinant antigens perform differently from assays based on purified flagella antigen.</p> <p>Methods</p> <p>We compared the use of recombinant antigens (LIAISON<sup>® </sup>DiaSorin, Saluggia, Italy) and purified flagella antigen (IDEIA™ Borrelia, DakoCytomation, Glostrup, Denmark) in the assay for <it>Borrelia</it>-specific IgM and IgG-antibodies. The assays were tested on an unselected population of serum samples submitted from general practice. A total of 357 consecutive samples for analysis of <it>Borrelia </it>IgM and IgG antibodies. Furthermore, we analysed 540 samples for <it>Borrelia</it>-specific IgM or IgG antibodies first by the IDEIA™ and, if they were positive, the samples were further analysed using the LIAISON<sup>® </sup>assay. To verify the correctness of the patient's serological status, discrepant samples were analysed by line blots (EcoLine, Virotech).</p> <p>Results</p> <p>In the consecutive series of 357 samples, the IgM assays detected 308 negative and 3 positive samples with concordant results. Compared with the line blot, the IDEIA™ system produced 21 false-positive IgM results, whereas the LIAISON<sup>® </sup>system produced only one false-positive IgM result. The IgG assays showed 1 positive and 328 negative concordant results. The LIAISON<sup>® </sup>system produced 9 true IgG-positive samples that were not detected by the IDEIA™ system, but the former produced 4 positive IgG results that were negative by line blot.</p> <p>Conclusion</p> <p>Diagnostic assays based on flagella antigen seem to show more false-positive IgM and false-negative IgG results than assays based on recombinant antigens. The latter may reduce the number of presumably false-positive IgM results and identify more IgG-positive subjects, but this system also produces more false-positive IgG results.</p
    corecore