3 research outputs found

    Klebsiella variicola causing nosocomial transmission among neonates - an emerging pathogen?

    No full text
    Introduction. Transmission of Enterobacterales in neonatal intensive care units (NICU) can cause outbreaks of colonization and invasive infections among neonates. Two clusters of nosocomial transmission of Klebsiella pneumoniae identified by MALDI-ToF mass-spectrometry were suspected at two NICUs in July and August 2016. Aim. To assess the potential transmission of K. pneumoniae among neonates. Methodology. Whole-genome sequencing (WGS) was performed of K. pneumoniae isolates obtained through targeted surveillance of patients and environmental sampling. Results. WGS data revealed that patient and environmental isolates represented two species, K. pneumoniae and K. variicola. Core-genome multi-locus sequence typing (cgMLST) of the isolates identified three separate transmission clusters, in Hospital A a cluster of K. pneumoniae isolates in 12 children and two environmental samples and a second cluster of K. variicola isolates in five children. In Hospital B a cluster of K. pneumoniae isolates from three children and five unrelated isolates of K. pneumoniae and two unrelated isolates of K. variicola were found. Conclusion. K. variicola can cause hospital outbreaks of colonization and infection similar to other Klebsiella spp

    CONTRAST-ENHANCED ULTRASOUND FOR THE DETECTION OF ABDOMINAL COMPLICATIONS IN INFECTIVE ENDOCARDITIS: FIRST EXPERIENCE FROM A PROSPECTIVE COHORT

    No full text
    Embolic events are associated with increased mortality in patients with infective endocarditis (IE). The goal of this study was to gain experience with the application of contrast-enhanced ultrasound (CEUS) in IE to detect abdominal complications. CEUS was performed in 40 patients from a prospective register of IE. CEUS was able to detect abdominal embolic events or metastatic infection in 12 patients (30%). Most commonly seen were splenic infarctions (n = 10), followed by renal infarction (n = 2), liver abscess (n = 1) and mycotic aneurysm (n = 1). Six out of 14 lesions were only detected by CEUS and not by conventional ultrasound. Abdominal complications revealed by CEUS were associated with a detectable valve vegetation (p = 0.04) and larger vegetation size (p = 0.01). In three patients, a non-IE related abdominal lesion (two hepatocellular carcinomas, one psoas hematoma) was detected. CEUS is a feasible diagnostic method in detection of abdominal complications of IE. (E-mail: [email protected]) (C) 2020 World Federation for Ultrasound in Medicine & Biology. All rights reserved
    corecore