    Influence of Storage Temperature on Radiochemical Purity of 99mTc-Radiopharmaceuticals

    Get PDF
    The influence of effective room temperature on the radiochemical purity of 99mTc-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the 99mTc-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the work area, the presence of instruments for heating, the continuous activation of air filtration, in addition to the fact that the environment of the isolator used for the 99mTc-radiopharmaceuticals preparation and storage is completely isolated and not conditioned. A total of 244 99mTc-radiopharmaceutical preparations (seven different types) have been tested and the radiochemical purity was checked at the end of preparation and until the expiry time. Moreover, we found that the mean temperature into the isolator was significantly higher than 25 C, the temperature, in general, required for the preparation and storage of 99mTc-radiopharmaceuticals. Results confirmed the radiochemical stability of radiopharmaceutical products. However, as required in the field of quality assurance, the impact that different conditions than those required by the manufacturer on the radiopharmaceuticals quality have to be verified before human administration

    Proteomic analysis of urine in medication-overuse headache patients: possible relation with renal damages

    Get PDF
    Medication-overuse headache (MOH) is a chronic disorder associated with overuse of analgesic drugs, triptans, non-steroidal anti-inflammatory drugs (NSAIDs) or other acute headache compounds. Various epidemiologic investigations proved that different drug types could cause nephrotoxicity, particularly in chronic patients. The aim of the present work was to analyze, by a proteomic approach, the urinary protein profiles of MOH patients focusing on daily use of NSAIDs, mixtures and triptans that could reasonably be related to potential renal damage. We selected 43 MOH patients overusing triptans (n = 18), NSAIDs (n = 11), and mixtures (n = 14), for 2–30 years with a mean daily analgesic intake of 1.5 ± 0.9 doses, and a control group composed of 16 healthy volunteers. Urine proteins were analyzed by mono-dimensional gel electrophoresis and identified by mass spectrometry analysis. Comparing the proteomic profiles of patients and controls, we found a significantly different protein expression, especially in the NSAIDs group, in which seven proteins resulted over-secreted from kidney (OR = 49, 95% CI 2.53–948.67 vs. controls; OR = 11.6, 95% CI 0.92–147.57 vs. triptans and mixtures groups). Six of these proteins (uromodulin, α-1-microglobulin, zinc-α-2-glycoprotein, cystatin C, Ig-kappa-chain, and inter-α-trypsin heavy chain H4) were strongly correlated with various forms of kidney disorders. Otherwise, in mixtures and in triptans abusers, only three proteins were potentially associated to pathological conditions (OR = 4.2, 95% CI 0.33–53.12, vs. controls). In conclusion, this preliminary proteomic study allowed us to define the urinary protein pattern of MOH patients that is related to the abused drug. According with the obtained results, we believe that the risk of nephrotoxicity should be considered particularly in MOH patients who abuse of NSAIDs

    Automated synthesis of 68Ga-DOTA-TOC with a cationic purification system: Evaluation of methodological and technical aspects in routine preparations

    No full text
    Background and Objective: Gallium-68 is a PET isotope available in each nuclear medicine departments, even those not equipped with a cyclotron, since it is easily obtained by eluting compact and transportable generator system. The preparation of Ga-68 DOTA-labeled compounds is performed by remotely controlled automated systems developed in order to ensure production efficiency, reproducibility of the results, fast reaction time, to facilitate the synthesis and minimize the radiation exposure. Many automatic synthesis systems are available on the radiopharmaceutical market, however, they Y requires some technical adaptations for routine use. We reported the [68Ga]Ga-DOTA-TOC production by automated cassette-based theranostic synthesizer system used in combination with a disposable GMP grade cassette system for cationic purification. Methods: The synthesizer is integrated with the68Ge/68Ga generator systems and it allows to perform elution, eluate purification and radiolabeling in about 38 minutes. We have performed in 2 year (January 2016-January 2018) over 100 [68Ga]Ga-DOTA-TOC preparations. Results: The average synthesis yield of radiopharmaceutical production was 54.4 ± 2.3 % and the radiochemical purity average was found 96.94 ± 0.74 %. Only three [68Ga]Ga-DOTA-TOC preparations have failed. Conclusion: The methodology and the adopted technical solutions allowed to obtain a high quality radiopharmaceutical product as required by the European Pharmacopoeia

    Influence of Storage Temperature on Radiochemical Purity of 99mTc-Radiopharmaceuticals

    No full text
    The influence of effective room temperature on the radiochemical purity of 99mTc-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the 99mTc-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the work area, the presence of instruments for heating, the continuous activation of air filtration, in addition to the fact that the environment of the isolator used for the 99mTc-radiopharmaceuticals preparation and storage is completely isolated and not conditioned. A total of 244 99mTc-radiopharmaceutical preparations (seven different types) have been tested and the radiochemical purity was checked at the end of preparation and until the expiry time. Moreover, we found that the mean temperature into the isolator was significantly higher than 25 °C, the temperature, in general, required for the preparation and storage of 99mTc-radiopharmaceuticals. Results confirmed the radiochemical stability of radiopharmaceutical products. However, as required in the field of quality assurance, the impact that different conditions than those required by the manufacturer on the radiopharmaceuticals quality have to be verified before human administration