13 research outputs found

    Differences in Atrial Remodeling in Hypertrophic Cardiomyopathy Compared to Hypertensive Heart Disease and Athletes’ Hearts.

    Get PDF
    BACKGROUND: Hypertrophic cardiomyopathy (HCM), hypertensive heart disease (HHD) and athletes' heart share an increased prevalence of atrial fibrillation. Atrial cardiomyopathy in these patients may have different characteristics and help to distinguish these conditions. METHODS: In this single-center study, we prospectively collected and analyzed electrocardiographic (12-lead ECG, signal-averaged ECG (SAECG), 24 h Holter ECG) and echocardiographic data in patients with HCM and HHD and in endurance athletes. Patients with atrial fibrillation were excluded. RESULTS: We compared data of 27 patients with HCM (70% males, mean age 50 +/- 14 years), 324 patients with HHD (52% males, mean age 75 +/- 5.5 years), and 215 endurance athletes (72% males, mean age 42 +/- 7.5 years). HCM patients had significantly longer filtered P-wave duration (153 +/- 26 ms) and PR interval (191 +/- 48 ms) compared to HHD patients (144 +/- 16 ms, p = 0.012 and 178 +/- 31, p = 0.034, respectively) and athletes (134 +/- 14 ms, p = 0.001 and 165 +/- 26 ms, both p &lt; 0.001, respectively). HCM patients had a mean of 4.9 +/- 16 premature atrial complexes per hour. Premature atrial complexes per hour were significantly more frequent in HHD patients (27 +/- 86, p &lt; 0.001), but not in athletes (2.7 +/- 23, p = 0.639). Left atrial volume index (LAVI) was 43 +/- 14 mL/m(2) in HCM patients and significantly larger than age- and sex-corrected LAVI in HHD patients 30 +/- 10 mL/m(2); p &lt; 0.001) and athletes (31 +/- 9.5 mL/m(2); p &lt; 0.001). A borderline interventricular septum thickness >/=13 mm and </=15 mm was found in 114 (35%) HHD patients, 12 (6%) athletes and 3 (11%) HCM patients. CONCLUSIONS: Structural and electrical atrial remodeling is more advanced in HCM patients compared to HHD patients and athletes

    Assessment of New Onset Arrhythmias After Transcatheter Aortic Valve Implantation Using an Implantable Cardiac Monitor.

    Get PDF
    Background Transcatheter aortic valve implantation (TAVI) is associated with new onset brady- and tachyarrhythmias which may impact clinical outcome. Aims To investigate the true incidence of new onset arrhythmias within 12 months after TAVI using an implantable cardiac monitor (ICM). Methods One hundred patients undergoing TAVI received an ICM within 3 months before or up to 5 days after TAVI. Patients were followed-up for 12 months after discharge from TAVI for the occurrence of atrial fibrillation (AF), bradycardia (≀30 bpm), advanced atrioventricular (AV) block, sustained ventricular and supraventricular tachycardia. Results A previously undiagnosed arrhythmia was observed in 31 patients (31%) and comprised AF in 19 patients (19%), advanced AV block in 3 patients (3%), and sustained supraventricular and ventricular tachycardia in 10 (10%) and 2 patients (2%), respectively. Three patients had a clinical diagnosis of sick-sinus-syndrome. A permanent pacemaker (PPM) was implanted in six patients (6%). The prevalence of pre-existing AF was 28%, and 47% of the patients had AF at the end of the study period. AF burden was significantly higher in patients with pre-existing [26.7% (IQR 0.3%; 100%)] compared to patients with new-onset AF [0.0% (IQR 0.0%; 0.06%); p = 0.001]. Three patients died after TAVI without evidence of an arrhythmic cause according to the available ICM recordings. Conclusions Rhythm monitoring for 12 months after TAVI revealed new arrhythmias, mainly AF, in almost one third of patients. Atrial fibrillation burden was higher in patients with prevalent compared to incident AF. Selected patients may benefit from short-term remote monitoring. Trial Registration https://clinicaltrials.gov/: NCT02559011

    The search for atrial fibrillation and its impact on public health

    Get PDF
    Atrial fibrillation may be clearly symptomatic and is easily amenable to state-of-the-art treatment, most importantly oral anticoagulation therapy for the prevention of thromboembolism. However, atrial fibrillation may also go unnoticed for long periods in many patients. This silent or subclinical atrial fibrillation is nevertheless associated with thromboembolic risk just like clinically evident atrial fibrillation. Early detection of atrial fibrillation in patients at increased thromboembolic risk and consequent oral anticoagulation therapy may have a significant impact on public health. This review focuses on screening recommendations for atrial fibrillation and on the impact of silent atrial fibrillation in various clinical scenarios

    Prognostic value of right ventricular dyssynchrony in adults with repaired tetralogy of Fallot

    Get PDF
    Objective Residual sequelae after surgical repair of tetralogy of Fallot (rTOF) affect clinical outcome. We investigated the prognostic impact of right ventricular (RV) dyssynchrony in adults with rTOF years after the surgical repair.Methods Patients from the Swiss Adult Congenital HEart disease Registry were included. NT-proBNP levels, echocardiography, exercise testing and MRI data were collected. An offline strain analysis to quantify RV-ventricular and interventricular dyssynchrony was performed. The standard deviation of the time-to-peak shortening (TTP) of six RV segments defined the RV Dyssynchrony Index (RVDI). Maximal difference of TTP between RV and left ventricular segments defined the interventricular shortening delay (IVSD). Predictors of a composite adverse event (arrhythmias, hospitalisation for heart failure and death) were identified by multivariate Cox regression analysis. Their median values were used to create a risk score.Results Out of 285 included patients (mean age 34±14 years), 33 patients (12%) experienced an adverse event during a mean follow-up of 48±21 months. No correlation was found between RVDI, IVSD and clinical events. NT-proBNP, right atrial area and peak heart rate were independent predictors of outcomes. After 4 years-follow-up, no adverse events occurred in patients at low risk (score=0 points), while an adverse event occurred in 62% of patients at high risk (score=3 points, p&lt;0.001).Conclusion In our cohort of adults with rTOF, surrogates of RV dyssynchrony did not correlate with outcomes. A multimodality approach was effective in predicting the risk for adverse events

    Incidental Arrhythmias During Atrial Fibrillation Screening With Repeat 7-Day Holter ECGs in a Hospital-Based Patient Population.

    Get PDF
    BACKGROUND Screening for atrial fibrillation (AF) may reveal incidental arrhythmias of relevance. The aim of this study was to describe incidental arrhythmias detected during screening for AF in the STAR-FIB (Predicting SilenT AtRial FIBrillation in Patients at High Thrombembolic Risk) cohort study. METHODS AND RESULTS In the STAR-FIB cohort study, we screened hospitalized patients for AF with 3 repeat 7-day Holter ECGs. We analyzed all Holter ECGs for the presence of the following incidental arrhythmias: (1) sinus node dysfunction, defined as sinus pause of ≄3 seconds' duration; (2) second-degree (including Wenckebach) or higher-degree atrioventricular block (AVB); (3) sustained supraventricular tachycardia of ≄30 seconds' duration; and (4) sustained ventricular tachycardia of ≄30 seconds' duration. We furthermore report treatment decisions because of incidental arrhythmias. A total of 2077 Holter ECGs were performed in 794 patients (mean age, 74.7 years; 49% women), resulting in a mean cumulative duration of analyzable ECG signal of 414±136 hours/patient. We found incidental arrhythmias in 94 patients (11.8%). Among these were sinus node dysfunction in 14 patients (1.8%), AVB in 41 (5.2%), supraventricular tachycardia in 42 (5.3%), and ventricular tachycardia in 2 (0.3%). Second-degree AVB was found in 23 patients (2.9%), 2:1 AVB in 10 (1.3%), and complete AVB in 8 (1%). Subsequently, 8 patients underwent pacemaker implantation, 1 for sinus node dysfunction (post-AF conversion pause of 9 seconds) and 7 for advanced AVB. One patient had an implantable cardioverter-defibrillator implanted for syncopal ventricular tachycardia. CONCLUSIONS Incidental arrhythmias were frequently detected during screening for AF in the STAR-FIB study and resulted in device therapy in 1.1% of our cohort patients

    Comparison of lead failure manifestation of Biotronik Linox with St. Jude Medical Riata and Medtronic Sprint Fidelis lead.

    No full text
    PURPOSE To compare lead failure manifestation and lead performance of the Biotronik Linox/Sorin Vigila defibrillator lead (Linox group) with the St. Jude Medical Riata/Riata ST (Riata group) and Medtronic Sprint Fidelis defibrillator leads (Fidelis group). METHODS We assessed the performance of all aforementioned leads implanted at our center and investigated the manifestation of lead failures. RESULTS Of 93 Linox, 86 Riata, and 81 Fidelis leads implanted at our center, 11 (12%), 22 (26%), and 25 (31%) leads failed during a median follow-up of 46, 61, and 84 months, respectively. Inappropriate shocks were delivered in 64% (Linox), 5% (Riata), and 32% (Fidelis) of lead failures; a device alert was noted in none (Linox), 5% (Riata), and 52% (Fidelis); and lead failure was a coincidental finding in 36% (Linox), 91% (Riata), and 16% (Fidelis) of cases (p < 0.001). Non-physiological high rate signals were observed in 73% (Linox), 27% (Riata), and 80% (Fidelis) of lead failures (p = 0.001) and damaged lead integrity was found in 36% (Linox), 73% (Riata), and 24% (Fidelis) of cases (p = 0.064). Lead survival at 5 years was 88%, 92%, and 71% for Linox, Riata, and Fidelis group, respectively. CONCLUSIONS The most frequent clinical manifestation of lead failure was inappropriate shocks for Linox, coincidental finding for Riata and device alert for Fidelis leads. Non-physiological high rate signals were frequently observed in Linox and Fidelis lead failures whereas in Riata lead failures, a damaged lead integrity was the predominant finding
    corecore