2 research outputs found

    Enhancing the evaporative cooling performance of fan-pad system using alternative pad materials and water film over the greenhouse roof

    Get PDF
    Greenhouse technology is a viable option for sustainable crop production in the regions of adverse climatic conditions.  During hot seasons the heat input to a greenhouse causes the internal temperature to exceed its optimal value.  The present study was devoted to construct an evaporative cooling system to reduce heat stress inside a greenhouse.  Two identical small-scale greenhouses were designed, constructed, and installed on an open roof of a domestic house.  The two greenhouses were cooled using fan-pad system.  In addition, a thin water film was applied on the roof of one greenhouse to study the effect of roof water film and fan-pad (combined system) on the cooling performance.  The two cooling systems were compared under the same condition.  Three new evaporative cooling pads represented by Cryperus Alopecuroides Rottb (Samar), Cyerus Alternifolius (Purdy) and Cyperus Rotundus l (Nut-grass or Se'd) were adapted and evaluated.  Three pad face air velocities ranged between 0.45 and 1.01 m s-1 and two thicknesses of 10 and 15 cm were used in the investigation of the cooling performance criteria.  Results showed that the proposed cooling pads in the suggested evaporative cooling systems were able to maintain acceptable microclimatic conditions for greenhouse models.  Se'd pad material proved more efficiency in temperature reduction.  It was revealed that the temperature inside the greenhouse operated under the combination of roof water flow and fan-pad system was less than that for fan-pad greenhouse by about 1.1 to 5.44° C in the morning and afternoon respectively.  The air relative humidity was increased due to humid effect provided by cooling system which protects crops from excessive transpiration and crop damage.  The daily average cooling efficiencies of 88.4, 83.1 and 79.6% were obtained for Se'd, Purdy and Samar, respectively during testing days inside the combined system at 15 cm pad thickness and 0.45 m s-1 pad face air velocity.  The Se'd pad material showed the highest efficiency as compared to other pad materials and could be used as an alternative pad material.   Keywords: greenhouse, evaporative cooling, fan-pad system, pad material, roof water flo

    International Nosocomial Infection Control Consortium report, data summary of 50 countries for 2010-2015: Device-associated module

    No full text
    •We report INICC device-associated module data of 50 countries from 2010-2015.•We collected prospective data from 861,284 patients in 703 ICUs for 3,506,562 days.•DA-HAI rates and bacterial resistance were higher in the INICC ICUs than in CDC-NHSN's.•Device utilization ratio in the INICC ICUs was similar to CDC-NHSN's. Background: We report the results of International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2010-December 2015 in 703 intensive care units (ICUs) in Latin America, Europe, Eastern Mediterranean, Southeast Asia, and Western Pacific. Methods: During the 6-year study period, using Centers for Disease Control and Prevention National Healthcare Safety Network (CDC-NHSN) definitions for device-associated health care-associated infection (DA-HAI), we collected prospective data from 861,284 patients hospitalized in INICC hospital ICUs for an aggregate of 3,506,562 days. Results: Although device use in INICC ICUs was similar to that reported from CDC-NHSN ICUs, DA-HAI rates were higher in the INICC ICUs: in the INICC medical-surgical ICUs, the pooled rate of central line-associated bloodstream infection, 4.1 per 1,000 central line-days, was nearly 5-fold higher than the 0.8 per 1,000 central line-days reported from comparable US ICUs, the overall rate of ventilator-associated pneumonia was also higher, 13.1 versus 0.9 per 1,000 ventilator-days, as was the rate of catheter-associated urinary tract infection, 5.07 versus 1.7 per 1,000 catheter-days. From blood cultures samples, frequencies of resistance of Pseudomonas isolates to amikacin (29.87% vs 10%) and to imipenem (44.3% vs 26.1%), and of Klebsiella pneumoniae isolates to ceftazidime (73.2% vs 28.8%) and to imipenem (43.27% vs 12.8%) were also higher in the INICC ICUs compared with CDC-NHSN ICUs. Conclusions: Although DA-HAIs in INICC ICU patients continue to be higher than the rates reported in CDC-NSHN ICUs representing the developed world, we have observed a significant trend toward the reduction of DA-HAI rates in INICC ICUs as shown in each international report. It is INICC's main goal to continue facilitating education, training, and basic and cost-effective tools and resources, such as standardized forms and an online platform, to tackle this problem effectively and systematically
    corecore