25 research outputs found

    Algorithm for cavo-tricuspid isthmus flutter on surface ECGs: the ACTIONS study.

    Get PDF
    OBJECTIVE: Cavo-tricuspid isthmus atrial flutter (CTI-AFL) is an important arrhythmia to recognise because there is a highly effective and relatively low-risk ablation strategy. However, clinical experience has demonstrated that providers often have difficulty distinguishing AFL from atrial fibrillation. METHODS: We developed a novel ECG-based three-step algorithm to identify CTI-AFL based on established CTI flutter characteristics and verified on consecutive ablation cases of typical flutter, atypical flutter and atrial fibrillation. The algorithm assesses V1/inferior lead F-wave concordance, consistency of P-wave morphology and the presence of isoelectric intervals in the inferior leads. In this observation study, the algorithm was validated on a cohort of 50 second-year medical students. Students were paired in a control and experimental group, and each pair received 10 randomly selected ECGs (from a pool of 50 intracardiac electrogram-proven CTI-AFL and 50 AF or atypical AFL cases). The experimental group received a cover sheet with the CTI algorithm, and the control group received no additional guidance. RESULTS: There was a statistically significant difference in the mean number of correctly identified ECGs among the students in the experimental and control groups (8.12 vs 5.68, p CONCLUSION: We developed a three-step ECG algorithm that provides a simple, sensitive, specific and accurate tool to identify CTI-AFL

    From the Editors

    Get PDF
    We are delighted to present you with the 21st annual edition of The Medicine Forum.Here in the birthplace of our nation, we like to think of The Medicine Forum as being of the housestaff, by the housestaff and for the housestaff. Undeniably, this publication would not be possible without the countless hours dedicated by our residents, students, fellows and faculty

    Recurrent Giant Cell Myocarditis After Heart Transplant: A Case Report

    Get PDF
    BACKGROUND: Giant cell myocarditis (GCM) is a rare but well-known cause of fulminant myocarditis. Despite optimal medical therapy, many patients progress to orthotopic heart transplant (OHT). We present a case of recurrent GCM following OHT, including complex considerations in patient management and infectious sequelae. CASE SUMMARY: A 33-year-old previously healthy male presented with 2 months of worsening shortness of breath. Transthoracic echocardiogram (TTE) demonstrated a left ventricular ejection fraction of 30-35%. After ruling out an ischaemic aetiology, he was discharged on guideline-directed medical therapy and later presented with productive cough, worsening dyspnoea on exertion, and diarrhoea. He was found to have elevated troponins and N-terminal pro-brain natriuretic peptide, lactic acidosis, progression of severe bi-ventricular dysfunction on TTE and right heart catheterization, and low cardiac index (1.0 L/min/m DISCUSSION: Although recurrent GCM after OHT has been reported in the literature, the prognosis is not well understood and there are no clear guidelines regarding management. This case summarizes clinical considerations, treatment strategies, and adverse effects of recurrent GCM treatment

    Initial Experience in Monitoring QT Intervals Using a Six-lead Contactless Mobile Electrocardiogram in an Inpatient Setting.

    Get PDF
    Mobile electrocardiograms (ECGs) (mECGs) using smartphone applications are an emerging technology. In the coronavirus disease 2019 (COVID-19) era, minimizing patient contact has gained increasing importance. Additionally, increased QT/corrected QT (QTc) monitoring has concurrently been required. The KardiaMobile 6L ECG device, cleared by the United States Food and Drug Administration (FDA) for recording ECGs, along with the KardiaStation tablet application is a platform (AliveCor, Mountain View, CA, USA) that addresses these two issues. A team of residents, fellows, hospitalists, and cardiologists identified inpatients in need of QT/QTc interval monitoring to pilot the adoption of a system composed of a KardiaMobile 6L ECG device with the accompanying KardiaStation tablet application. Concurrent standard ECGs provided validation. Adoption and performance issues were recorded. Four patients agreed to participate in QT/QTc interval monitoring, three of whom were positive for severe acute respiratory syndrome coronavirus 2 viral infection. After basic instructions were given to the patients and their clinical nurses, all patients recorded mECGs successfully. Patients were able to record their own mECG tracings at least once without any assistance. The 12-lead ECGs and mECGs each showed the correct rhythm, and the measured QTc intervals on each modality were consistently acceptable (\u3c 500 ms). Contactless ECGs were successfully uploaded to KardiaStation for QT/QTc interval measurement and archiving. In this study, we showed that an FDA-cleared product, KardiaMobile 6L, has the ability to provide high-quality contactless ECGs for reliable QT/QTc interval measurements. Hospitalized patients were able to perform recordings when requested after receiving simple instructions at the time of first use. This technology has applications during the COVID-19 pandemic and beyond

    Outpatient Mineralocorticoid Receptor Antagonist Prescription Rate for Heart Failure

    Get PDF
    Aims for Improvement: Improve MRA prescription rate in the outpatient cardiology clinic by 25

    Can Our Hearts Take the New Guidelines?

    Get PDF

    Comparison of left ventricular rotational mechanics between term and extremely premature infants over the first week of age

    No full text
    Objective Left ventricle (LV) rotational mechanics is an emerging tool to characterise LV function, but warrants further evaluation in neonates. The aim of this study was to compare LV rotational mechanics between term and extremely preterm babies over the first week of age.Methods In this prospective study, we serially assessed LV rotational parameters in 50 term infants and compared them with a historical dataset of 50 preterm infants born <29 weeks gestation. LV basal and apical rotation, LV twist, LV twist/untwist rate and torsion were derived using two-dimensional speckle tracking echocardiography at three time points over the first week of age.Results There was no change in LV twist, LV torsion, basal rotation or apical rotation in term infants over the study period (all p>0.05). LV twist and torsion were higher in preterm infants, and increased over time. In preterm infants, basal rotation evolved from anticlockwise to clockwise rotation. Apical rotation remained anticlockwise in both groups (all p>0.05). LV twist rate (LVTR) and untwist rate was higher in preterm infants and increased over the three time points (all p>0.05). There was a strong positive correlation between LV torsion and LV untwist rate (LVUTR) in the entire cohort during the third scan.Conclusion Term infants exhibit minimal LV twist which remains unchanged over the first week of age. This is in contrast to premature infants who demonstrate increasing indices of twist, torsion, LVTR and LVUTR over the first week, likely as a compensatory mechanism for reduced LV compliance

    A Strategy for Noise Reduction to Improve Patient Experiences with Sleep (SNORES)

    Get PDF
    Aim Our aim was to improve patient-reported sleep satisfaction on the 5 W telemetry unit at Thomas Jefferson University Hospital over a 4 month time period (11/2018 to 2/2019) using a Marpac white noise machine.https://jdc.jefferson.edu/patientsafetyposters/1119/thumbnail.jp

    From the Editors

    Get PDF
    We are delighted to present you with the 20th annual edition of The Medicine Forum. Here in the birthplace of our nation, we like to think of The Medicine Forum as being of the housestaff, by the housestaff and for the housestaff. Undeniably, this publication would not be possible without the countless hours dedicated by our residents, students, fellows and faculty
    corecore