49 research outputs found

    Aorto-atrial fistula formation and therapy

    Get PDF
    Aorta-atrial fistulas (AAF) are a rare but complex pathological condition. These fistulas are characterised by aberrant blood flow between the aorta and either atrium. In the present manuscript, we present a comprehensive overview of the clinical characteristics, formation and treatment of this condition. A literature review was conducted using PubMed. Aorta-Atrial Fistula was used as the primary search term. The clinical presentation of AAF encompasses a wide range of signs and symptoms of heart failure including dyspnoea, chest pain, palpitations, fatigue, weakness coughing or oedema. Causes of fistulas can be congenital or acquired, whilst diagnosis is normally achieved via echocardiography or MRI. Due to the low incidence of AAF, no clinical trials have been performed in AAF patients and treatment strategies are based on expert opinion and consensus amongst the treating physicians. Uncorrected AAF may continue to impose a risk of progression to overt heart failure. The repair of an AAF can either be surgical or percutaneous. AAF is a relatively rare but very serious condition. Clinicians should consider the possibility of AAF, when a new continuous cardiac murmur occurs, especially in patients with a history of cardiac surgery or with signs of heart failure. Closure of the AAF fistula tract is generally recommended. Further studies are required to define optimal therapeutic strategies, but these are hindered by the rarity of the occurrence of this disorde

    Aorto-atrial fistula formation and closure: a systematic review

    Get PDF
    Blood flow between the aorta and atrium is a rare but complex pathological condition, also known as aorto-atrial fistula (AAF). The exact incidence of this condition is unknown, as are the major precipitating factors and best treatment options. We carried out a systematic review of the available case report literature reporting AAF. We systematically reviewed literature on AAF formation and closure. Separate Medline (PubMed), EMBASE, and Cochrane database queries were performed. The following MESH headings were used: atrium, ventricle, fistula, cardiac, shunts, aortic, aorto-atrial tunnels and coronary cameral fistula. All papers were considered for analysis irrespective of their quality, or the journal in which they were published. Fistula formation from the ascending aorta to the atria occurred more often in the right atrium compared to the left. Endocarditis was the major cause of AAF formation, whilst congenital causes were responsible for nearly 12%. In a number of cases fistula formation occurred secondary to cardiac surgery, whilst chest traumas were a relatively rare cause of AAF. Correction via an open surgical approach occurred in 73.5% of cases, whilst percutaneous intervention was utilised in 10% of patients. In 74.3% of all studied cases the fistula repair was successful and patients survived the procedures. In 14.7% of the cases patients did not survive. Similar outcomes were observed between percutaneous and surgical interventions. Data from larger populations with AAF is lacking, meaning that specific data regarding incidence and prevalence does currently not exist

    Open repair of type Ia endoleak in the aortic arch: three tailored approaches

    Get PDF
    Endoleaks are an important complication following hybrid thoracic endovascular aortic repair (TEVAR) with an incidence ranging from 20% to 25%. There are five different types of endoleaks, which are classified based on the source of vessels that cause the inflow into the aneurysm sac. Type I endoleaks (EL-I) occur at either the proximal (Ia) or distal (Ib) attachment sites and can be seen during insertion of the initial stent graft or during a follow-up surveillance imaging exam. EL-I may be secondary to incomplete dilatation or inaccurate sizing of the stent graft, diseased aortic wall or aortic tortuosity with angulations, leading to higher chances of rupture. However, EL-I represent a technical failure of endovascular repair that should be corrected promptly. However, endovascular EL-I repair at the level of aortic arch is not always possible due to an improper landing zone in the ascending aorta making it technically challenging. In the present paper, we describe three cases of EL-Ia following TEVAR and we address different repair techniques. Written informed consents were obtained from the patients for publication of the article and any accompanying images

    Novel hemostatic patch achieves sutureless epicardial wound closure during complex cardiac surgery:A case report

    Get PDF
    Treatment of damaged cardiac tissue in patients with high bleeding tendency can be very challenging, damaged myocardial tissue has a high rupture risk when being sutured subsequently on-going bleeding is a major risk factor for poor clinical outcome. We present a case demonstrating the feasibility in using a novel haemostatic collagen sponge for the management of a myocardial wound. This report is the first description in cardiac surgery where Hemopatch (R) sponges are used to successfully seal a left ventricle wound. Our patient was diagnosed with endocarditis, had a low pre-operative haemoglobin count and underwent cardiac surgery for multiple valve repairs. The procedure was performed on cardiopulmonary bypass, which meant our patient had to be heparinized. Despite these major risk factors for bleeding Hemopatch (R) managed to contain bleeding and seal the wound, no sutures were needed

    Catching a floating thrombus:a case report on the treatment of a large thrombus in the ascending aorta

    Get PDF
    Background: The ascending aorta is an uncommon site for non-infective thrombus. In non-aneurysmal and non-atherosclerotic vessels this condition becomes extremely rare, while it represents a source of potential cerebral and peripheral embolic events. Currently, there is no consensus in the guidelines on how to treat a free floating thrombus in ascending aorta, therefore we present our decision making process and therapeutic strategy. Case presentation: A healthy 48-year-old man was hospital admitted with acute abdominal pain. CT-scan showed a right renal embolism in presence of a defect in the distal ascending aorta suggestive for thrombus. After heart team discussion the patient was scheduled for surgery and successfully underwent an emergent thrombus removal. Also, owing to multiple aortic wall insertions, the ascending aorta was replaced. The patient's recovery was uneventful and histological examination showed no signs of connective tissue disorders of aortic wall while confirmed the thrombotic nature of the mass. Conclusions: We present a patient with a floating thrombus in the ascending aorta who underwent an ascending aorta replacement. While angio-CT scan led to a prompt diagnosis, intraoperative epi-aortic echocardiography allowed to define precise location of thrombus, minimizing operative risk. This case demonstrates that multi-disciplinary heart team discussion is essential to define a successful strategy, that surgical treatment is feasible with specific tools such as epi-aortic echocardiography

    Long-term survival after mitral valve surgery for post-myocardial infarction papillary muscle rupture

    Get PDF
    Background: Papillary muscle rupture (PMR) is a rare, but dramatic mechanical complication of myocardial infarction (MI), which can lead to rapid clinical deterioration and death. Immediate surgical intervention is considered the optimal and most rational treatment, despite high risks. In this study we sought to identify overall long-term survival and its predictors for patients who underwent mitral valve surgery for post-MI PMR. Methods: Fifty consecutive patients (mean age 64.7 +/- 10.8 years) underwent mitral valve repair (n = 10) or replacement (n = 40) for post-MI PMR from January 1990 through May 2014. Clinical data, echocardiographic data, catheterization data, and surgical data were stored in a dedicated database. Follow-up was obtained in June of 2014; mean follow-up was 7.1 +/- 6.8 years (range 0.0-22.2 years). Univariate and multivariate Cox proportional hazard regression analyses were performed to identify predictors of long-term survival. Kaplan-Meier curves were compared with the log-rank test. Results: Kaplan-Meier cumulative survival at 1, 5, 10, 15, and 20 years was 71.9 +/- 6.4%, 65.1 +/- 6.9%, 49.5 +/- 7.6%, 36.1 +/- 8.0% and 23.7 +/- 9.2%, respectively. Univariate and multivariate analyses revealed logistic EuroSCORE >= 40% and EuroSCORE II >= 25% as strong independent predictors of a lower overall long-term survival. After removal of the EuroSCOREs from the model, preoperative inotropic drug support and mitral valve replacement (MVR) without (partial or complete) preservation of the subvalvular apparatus were independent predictors of a lower overall long-term survival. Conclusions: Logistic EuroSCORE >= 40%, EuroSCORE II >= 25%, preoperative inotropic drug support and MVR without (partial or complete) preservation of the subvalvular apparatus are strong independent predictors of a lower overall long-term survival in patients undergoing mitral valve surgery for post-MI PMR. Whenever possible, the subvalvular apparatus should be preserved in these patients

    The Maastricht Acquisition Platform for Studying Mechanisms of Cell–Matrix Crosstalk (MAPEX):An Interdisciplinary and Systems Approach towards Understanding Thoracic Aortic Disease

    Get PDF
    Current management guidelines for ascending thoracic aortic aneurysms (aTAA) recommend intervention once ascending or sinus diameter reaches 5–5.5 cm or shows a growth rate of &gt;0.5 cm/year estimated from echo/CT/MRI. However, many aTAA dissections (aTAAD) occur in vessels with diameters below the surgical intervention threshold of &lt;55 mm. Moreover, during aTAA repair surgeons observe and experience considerable variations in tissue strength, thickness, and stiffness that appear not fully explained by patient risk factors. To improve the understanding of aTAA pathophysiology, we established a multi-disciplinary research infrastructure: The Maastricht acquisition platform for studying mechanisms of tissue–cell crosstalk (MAPEX). The explicit scientific focus of the platform is on the dynamic interactions between vascular smooth muscle cells and extracellular matrix (i.e., cell–matrix crosstalk), which play an essential role in aortic wall mechanical homeostasis. Accordingly, we consider pathophysiological influences of wall shear stress, wall stress, and smooth muscle cell phenotypic diversity and modulation. Co-registrations of hemodynamics and deep phenotyping at the histological and cell biology level are key innovations of our platform and are critical for understanding aneurysm formation and dissection at a fundamental level. The MAPEX platform enables the interpretation of the data in a well-defined clinical context and therefore has real potential for narrowing existing knowledge gaps. A better understanding of aortic mechanical homeostasis and its derangement may ultimately improve diagnostic and prognostic possibilities to identify and treat symptomatic and asymptomatic patients with existing and developing aneurysms.</p

    Sonication of heart valves detects more bacteria in infective endocarditis

    Get PDF
    Optimal antimicrobial treatment of infective endocarditis requires identification and susceptibility patterns of pathogens. Sonication of explanted heart valves could increase the identification and culture of pathogens, as shown in prosthetic joint and pacemaker/ICD infections. We tested 26 explanted heart valves from 20 patients with active definite endocarditis for added diagnostic value of sonication to the standard microbiological workup in a prospective diagnostic proof of concept study. Two sonication protocols (broth enrichment vs. centrifugation) were compared in an additional 35 negative control valves for contamination rates. We selected sonication/centrifugation based on acceptable false positive rates (11.4%; 4/35). Sonication/enrichment yielded many false positive results in negative controls (28.6%; 10/35), mainly Propionibacterium acnes (next-generation sequencing excluded technical problems). Compared to direct culture only, adding sonication/centrifugation (including molecular testing) significantly increased the diagnostic yield from 6/26 to 17/26 valves (p = 0.003). Most importantly, culture positives almost doubled (from 6 to 10), providing unique quantitative information about antimicrobial susceptibility. Even if direct molecular testing was added to the standard workup, sonication/centrifugation provided additional diagnostic information in a significant number of valves (8/26; 31%; p = 0.013). We concluded that sonication/centrifugation added relevant diagnostic information in the workup of heart valves with infective endocarditis, with acceptable contamination rates

    A standardized approach to treat complex aortic valve endocarditis: a case series

    Get PDF
    Background Surgical treatment of complicated aortic valve endocarditis often is challenging, even for experienced surgeons. We aim at demonstrating a standardized surgical approach by stentless bioprostheses for the treatment of aortic valve endocarditis complicated by paravalvular abscess formation. MethodsSixteen patients presenting with aortic valve endocarditis (4 native and 12 prosthetic valves) and paravalvular abscess formation at various localizations and to different extents were treated by a standardized approach using stentless bioprostheses. The procedure consisted of thorough debridement, root replacement with reimplantation of the coronary arteries and correction of accompanying pathologies (aortoventricular and aortomitral dehiscence, septum derangements, Gerbode defect, total atrioventricular conduction block, mitral and tricuspid valve involvement).ResultsAll highly complex patients included (14 males and 2 females; median age 63 years [range 31–77]) could be successfully treated with stentless bioprostheses as aortic root replacement. Radical surgical debridement of infected tissue with anatomical recontruction was feasible. Although predicted operative mortality was high (median logarithmic EuroSCORE I of 40.7 [range 12.8–68.3]), in-hospital and 30-day mortality rates were favorable (18.8 and 12.5% respectively). ConclusionsRepair of active aortic valve endocarditis complicated by paravalvular abscess formation and destruction of the left ventricular outflow tract with stentless bioprosthesis is a valuable option for both native and prosthetic valves. It presents a standardized approach with a high success rate for complete debridement, is readily available, and yields comparable clinical outcomes to the historical gold standard, repair by homografts. Additionally, use of one type of prosthesis reduces logistical issues and purchasing costs
    corecore