37 research outputs found

    Do distribution volumes and clearances relate to tissue volumes and blood flows? A computer simulation

    Get PDF
    BACKGROUND: Kinetics of inhaled agents are often described by physiological models. However, many pharmacokinetic concepts, such as context-sensitive half-times, have been developed for drugs described by classical compartmental models. We derived classical compartmental models that describe the course of the alveolar concentrations (F(A)) generated by the physiological uptake and distribution models used by the Gas Man(® )program, and describe how distribution volumes and clearances relate to tissue volumes and blood flows. METHODS: Gas Man(® )was used to generate F(A )vs. time curves during the wash-in and wash-out period of 115 min each with a high fresh gas flow (8 L.min(-1)), a constant alveolar minute ventilation (4 L.min(-1)), and a constant inspired concentration (F(I)) of halothane (0.75%), isoflurane (1.15%), sevoflurane (2%), or desflurane (6%). With each of these F(I), simulations were ran for a 70 kg patient with 5 different cardiac outputs (CO) (2, 3, 5, 8 and 10 L.min(-1)) and for 5 patients with different weights (40, 55, 70, 85, and 100 kg) but the same CO (5 L.min(-1)). Two and three compartmental models were fitted to F(A )of the individual 9 runs using NONMEM. After testing for parsimony, goodness of fit was evaluated using median prediction error (MDPE) and median absolute prediction error (MDAPE). The model was tested prospectively for a virtual 62 kg patient with a cardiac output of 4.5 L.min(-1 )for three different durations (wash-in and wash-out period of 10, 60, and 180 min each) with an F(I )of 1.5% halothane, 1.5% isoflurane, sevoflurane 4%, or desflurane 12%. RESULTS: A three-compartment model fitted the data best (MDPE = 0% and MDAPE ≤ 0.074%) and performed equally well when tested prospectively (MDPE ≤ 0.51% and MDAPE ≤ 1.51%). The relationship between CO and body weight and the distribution volumes and clearances is complex. CONCLUSION: The kinetics of anesthetic gases can be adequately described e by a mammilary compartmental model. Therefore, concepts that are traditionally thought of as being applicable to the kinetics of intravenous agents can be equally well applied to anesthetic gases. Distribution volumes and clearances cannot be equated to tissue volumes and blood flows respectively

    Heterogeneity of human adipose blood flow

    Get PDF
    BACKGROUND: The long time pharmacokinetics of highly lipid soluble compounds is dominated by blood-adipose tissue exchange and depends on the magnitude and heterogeneity of adipose blood flow. Because the adipose tissue is an infinite sink at short times (hours), the kinetics must be followed for days in order to determine if the adipose perfusion is heterogeneous. The purpose of this paper is to quantitate human adipose blood flow heterogeneity and determine its importance for human pharmacokinetics. METHODS: The heterogeneity was determined using a physiologically based pharmacokinetic model (PBPK) to describe the 6 day volatile anesthetic data previously published by Yasuda et. al. The analysis uses the freely available software PKQuest and incorporates perfusion-ventilation mismatch and time dependent parameters that varied from the anesthetized to the ambulatory period. This heterogeneous adipose perfusion PBPK model was then tested by applying it to the previously published cannabidiol data of Ohlsson et. al. and the cannabinol data of Johansson et. al. RESULTS: The volatile anesthetic kinetics at early times have only a weak dependence on adipose blood flow while at long times the pharmacokinetics are dominated by the adipose flow and are independent of muscle blood flow. At least 2 adipose compartments with different perfusion rates (0.074 and 0.014 l/kg/min) were needed to describe the anesthetic data. This heterogeneous adipose PBPK model also provided a good fit to the cannabinol data. CONCLUSION: Human adipose blood flow is markedly heterogeneous, varying by at least 5 fold. This heterogeneity significantly influences the long time pharmacokinetics of the volatile anesthetics and tetrahydrocannabinol. In contrast, using this same PBPK model it can be shown that the long time pharmacokinetics of the persistent lipophilic compounds (dioxins, PCBs) do not depend on adipose blood flow. The ability of the same PBPK model to describe both the anesthetic and cannabinol kinetics provides direct qualitative evidence that their kinetics are flow limited and that there is no significant adipose tissue diffusion limitation

    Mapping the contribution of β3-containing GABA(A )receptors to volatile and intravenous general anesthetic actions

    Get PDF
    BACKGROUND: Agents belonging to diverse chemical classes are used clinically as general anesthetics. The molecular targets mediating their actions are however still only poorly defined. Both chemical diversity and substantial differences in the clinical actions of general anesthetics suggest that general anesthetic agents may have distinct pharmacological targets. It was demonstrated previously that the immobilizing action of etomidate and propofol is completely, and the immobilizing action of isoflurane partly mediated, by β3-containing GABA(A )receptors. This was determined by using the β3(N265M) mice, which carry a point mutation known to decrease the actions of general anesthetics at recombinant GABA(A )receptors. In this communication, we analyzed the contribution of β3-containing GABA(A )receptors to the pharmacological actions of isoflurane, etomidate and propofol by means of β3(N265M) mice. RESULTS: Isoflurane decreased core body temperature and heart rate to a smaller degree in β3(N265M) mice than in wild type mice, indicating a minor but significant role of β3-containing GABA(A )receptors in these actions. Prolonged time intervals in the ECG and increased heart rate variability were indistinguishable between genotypes, suggesting no involvement of β3-containing GABA(A )receptors. The anterograde amnesic action of propofol was indistinguishable in β3(N265M) and wild type mice, suggesting that it is independent of β3-containing GABA(A )receptors. The increase of heart rate variability and prolongation of ECG intervals by etomidate and propofol were also less pronounced in β3(N265M) mice than in wild type mice, pointing to a limited involvement of β3-containing GABA(A )receptors in these actions. The lack of etomidate- and propofol-induced immobilization in β3(N265M) mice was also observed in congenic 129X1/SvJ and C57BL/6J backgrounds, indicating that this phenotype is stable across different backgrounds. CONCLUSION: Our results provide evidence for a defined role of β3-containing GABA(A )receptors in mediating some, but not all, of the actions of general anesthetics, and confirm the multisite model of general anesthetic action. This pharmacological separation of anesthetic endpoints also suggests that subtype-selective substances with an improved side-effect profile may be developed

    Reliability of the volatile agent consumption display in the Draeger Primusâ„¢ anesthesia machine

    Full text link
    Knowledge of the consumed amount of volatile anesthetic (VA) expressed in liquid agent is necessary to enable agent sparing dosing measures and for billing purposes. The widespread Draeger Primus™ anesthesia machine displays in its logbook the amount of consumed VA at the end of each anesthesia, but the reliability of this parameter is yet unknown. The objective was to evaluate the precision and reliability of the inbuilt VA consumption display in Draeger Primus™ anesthesia machines as compared with the gold standard of weighing the vaporizer before and after anesthesia. In this prospective laboratory investigation we compared the VA consumption displayed by the Draeger Primus™ anesthesia machine with measured vaporizer weight differences before and after 10 sevoflurane and 10 desflurane anesthesias. We assessed the average difference and spread of values between the predicted (displayed) and measured (control) values for VA consumption. The displayed sevoflurane consumption overestimated the measured values by 4.3 ± 5.4 ml (7.6 %). The displayed desflurane consumption underestimated the measured values by -3.5 ± 6.3 ml (6.2 %). Nine from 10 sevoflurane pairs of values and all desflurane pairs of values were within ±1.96 SD. The displayed VA consumption calculations for sevoflurane and desflurane in the Draeger Primus™ are sufficiently reliable to estimate the pharmacoeconomic impact of VA delivery during inhalational anesthesia