5 research outputs found

    Impact of Propofol Bolus Administration on the Nociceptive Flexion Reflex Threshold and Bispectral Index in Children—A Case Series

    No full text
    We analyzed the impact of propofol administration during continuous sedation and analgesia on the nociceptive flexion reflex threshold (NFRT) and Bispectral Index (BIS) in ventilated children. We examined patients who received propofol before planned endotracheal suctioning. Patients were clinically assessed using the modified Face, Legs, Activity, Cry, Consolability (mFLACC) scale and COMFORT-B (Comfort Behavior) scale. We continuously recorded the NFRT and BIS. We recorded 23 propofol administrations in eight patients with an average age of 8.6 ± 3.5 years. The median (minimum-maximum) scores for the mFLACC scale and COMFORT-B scale were 0 (0–5) and 6 (6–17), respectively, before the bolus. The administration of a weight-adjusted propofol bolus of 1.03 ± 0.31 mg/kg resulted in an increase in NFRT and burst-suppression ratio; BIS and electromyogram values decreased. Changes from baseline (95% CI) after propofol bolus administration were BIS −23.9 (−30.8 to −17.1), EMG -10.5 dB (−13.3 to −7.7), SR 14.8 % (5.6 to 24.0) and NFRT 13.6 mA (5.5 to 21.7). Further studies are needed to determine whether sedated children may benefit from objective pain and sedation monitoring with BIS and NFRT

    Pilot study of an interprofessional pediatric mechanical ventilation educational initiative in two intensive care units

    No full text
    Abstract Introduction Inappropriate ventilator settings, non-adherence to a lung-protective ventilation strategy, and inadequate patient monitoring during mechanical ventilation can potentially expose critically ill children to additional risks. We set out to improve team theoretical knowledge and practical skills regarding pediatric mechanical ventilation and to increase compliance with treatment goals. Methods An educational initiative was conducted from August 2019 to July 2021 in a neonatal and pediatric intensive care unit of the University Children’s Hospital, Hamburg-Eppendorf, Germany. We tested baseline theoretical knowledge using a multiple choice theory test (TT) and practical skills using a practical skill test (PST), consisting of four sequential Objective Structured Clinical Examinations of physicians and nurses. We then implemented an educational bundle that included video self-training, checklists, pocket cards, and reevaluated team performance. Ventilators and monitor settings were randomly checked in all ventilated patients. We used a process control chart and a mixed-effects model to analyze the primary outcome. Results A total of 47 nurses and 20 physicians underwent assessment both before and after the implementation of the initiative using TT. Additionally, 34 nurses and 20 physicians were evaluated using the PST component of the initiative. The findings revealed a significant improvement in staff performance for both TT and PST (TT: 80% [confidence interval (CI): 77.2–82.9] vs. 86% [CI: 83.1–88.0]; PST: 73% [CI: 69.7–75.5] vs. 95% [CI: 93.8–97.1]). Additionally, there was a notable increase in self-confidence among participants, and compliance with mechanical ventilation treatment goals also saw a substantial rise, increasing from 87.8% to 94.5%. Discussion Implementing a pediatric mechanical ventilation education bundle improved theoretical knowledge and practical skills among interprofessional pediatric intensive care staff and increased treatment goal compliance in ventilated children

    Anatomic accuracy, physiologic characteristics, and fidelity of very low birth weight infant airway simulators

    No full text
    Background!#!Medical simulation training requires realistic simulators with high fidelity. This prospective multi-center study investigated anatomic precision, physiologic characteristics, and fidelity of four commercially available very low birth weight infant simulators.!##!Methods!#!We measured airway angles and distances in the simulators Premature AirwayPaul (SIMCharacters), Premature Anne (Laerdal Medical), Premie HAL S2209 (Gaumard), and Preterm Baby (Lifecast Body Simulation) using computer tomography and compared these to human cadavers of premature stillbirths. The simulators' physiologic characteristics were tested, and highly experienced experts rated their physical and functional fidelity.!##!Results!#!The airway angles corresponded to those of the reference cadavers in three simulators. The nasal inlet to glottis distance and the mouth aperture to glottis distance were only accurate in one simulator. All simulators had airway resistances up to 20 times higher and compliances up to 19 times lower than published reference values. Fifty-six highly experienced experts gave three simulators (Premature AirwayPaul: 5.1 ± 1.0, Premature Anne 4.9 ± 1.1, Preterm Baby 5.0 ± 1.0) good overall ratings and one simulator (Premie HAL S2209: 2.8 ± 1.0) an unfavorable rating.!##!Conclusion!#!The simulator physiology deviated significantly from preterm infants' reference values concerning resistance and compliance, potentially promoting a wrong ventilation technique.!##!Impact!#!Very low birth weight infant simulators showed physiological properties far deviating from corresponding patient reference values. Only ventilation with very high peak pressure achieved tidal volumes in the simulators, as aimed at in very low birth weight infants, potentially promoting a wrong ventilation technique. Compared to very low birth weight infant cadavers, most tested simulators accurately reproduced the anatomic angular relationships, but their airway dimensions were relatively too large for the represented body. The more professional experience the experts had, the lower they rated the very low birth weight infant simulators

    Anatomic accuracy, physiologic characteristics, and fidelity of very low birth weight infant airway simulators

    No full text
    Background Medical simulation training requires realistic simulators with high fidelity. This prospective multi-center study investigated anatomic precision, physiologic characteristics, and fidelity of four commercially available very low birth weight infant simulators. Methods We measured airway angles and distances in the simulators Premature AirwayPaul (SIMCharacters), Premature Anne (Laerdal Medical), Premie HAL S2209 (Gaumard), and Preterm Baby (Lifecast Body Simulation) using computer tomography and compared these to human cadavers of premature stillbirths. The simulators' physiologic characteristics were tested, and highly experienced experts rated their physical and functional fidelity. Results The airway angles corresponded to those of the reference cadavers in three simulators. The nasal inlet to glottis distance and the mouth aperture to glottis distance were only accurate in one simulator. All simulators had airway resistances up to 20 times higher and compliances up to 19 times lower than published reference values. Fifty-six highly experienced experts gave three simulators (Premature AirwayPaul: 5.1 +/- 1.0, Premature Anne 4.9 +/- 1.1, Preterm Baby 5.0 +/- 1.0) good overall ratings and one simulator (Premie HAL S2209: 2.8 +/- 1.0) an unfavorable rating. Conclusion The simulator physiology deviated significantly from preterm infants' reference values concerning resistance and compliance, potentially promoting a wrong ventilation technique. Impact Very low birth weight infant simulators showed physiological properties far deviating from corresponding patient reference values. Only ventilation with very high peak pressure achieved tidal volumes in the simulators, as aimed at in very low birth weight infants, potentially promoting a wrong ventilation technique. Compared to very low birth weight infant cadavers, most tested simulators accurately reproduced the anatomic angular relationships, but their airway dimensions were relatively too large for the represented body. The more professional experience the experts had, the lower they rated the very low birth weight infant simulators