91 research outputs found

    Impact of repeated percutaneous coronary intervention on long-term survival after subsequent coronary artery bypass surgery

    Get PDF
    <p>Abstract</p> <p>(Background)</p> <p>In the current stent era, aggressive repeated percutaneous coronary intervention (PCI) has become more common. The aim of this study was to investigate the impact of previous repeated PCI on the subsequent coronary artery bypass grafting (CABG).</p> <p>(Methods)</p> <p>Between January 1990 and January 2008, a total of 894 patients underwent first-time isolated elective CABG. Among the 894 patients, 515 patients had had no PCI (group A), 179 patients had had single PCI (Group B), and 200 patients had had multiple PCI (2-15 times, mean 3.6 ± 2.3 times) (group C) before CABG. These groups were compared in terms of early and late clinical results.</p> <p>(Results)</p> <p>Preoperative left ventricular ejection fraction was significantly higher in group A (group A;58 ± 13%, group B;54 ± 12%, and group C;54 ± 12%). Number of bypass grafts was significantly smaller in group C (A:3.3 ± 1.0, B 3.4 ± 0.9, C 3.1 ± 1.0). Although there was no statistically significant difference among the groups, in-hospital mortality in group C was higher than that in group A and B (A:1.6%, B:1.1%, C:3.5%, p = 0.16). Survival analysis by Kaplan-Meier method (mean follow-up: 58 ± 43 methods) revealed that freedom from all-cause death and cardiac death was significantly lower in group C in comparison with group A. Freedom from cardiac event was significantly higher in group C than that in group A. Multivariate analysis identified a number of previous PCI as an independent risk factor for cardiac death.</p> <p>(Conclusions)</p> <p>Repeated PCI increased risk for long-term prognosis of subsequent CABG.</p

    Final 5-year clinical and echocardiographic results for treatment of severe aortic stenosis with a self-expanding bioprosthesis from the ADVANCE Study.

    Get PDF
    Aims: The ADVANCE study was designed to evaluate the safety and effectiveness of transcatheter aortic valve implantation (TAVI) with a self-expanding bioprosthesis in real-world patients with symptomatic, severe aortic stenosis at high surgical risk for valve replacement. Methods and results: Study participants were enrolled from 44 experienced centres in 12 countries. Patient eligibility, treatment approach, and choice of anaesthesia were determined by the local Heart Team. The study was 100% monitored, and adverse events were adjudicated by an independent clinical events committee using Valve Academic Research Consortium (VARC-1) criteria. There were 1015 patients enrolled with 996 attempted TAVI procedures. Mean age was 81 years, and mean logistic EuroSCORE was 19.3 ± 12.3%. Five-year follow-up was available on 465 (46.7%) patients. At 5 years, the rate of all-cause mortality was 50.7% (95% confidence interval: 46.7%, 54.5%), and the rate of major stroke was 5.4%. Haemodynamic measures remained consistent for paired patients with a mean aortic valve gradient of 8.8 ± 4.4 mmHg (n = 198) and an effective orifice area of 1.7 ± 0.4 cm2 (n = 123). Aortic regurgitation (AR) decreased over time and among paired patients dropped from 12.8% to 8.0% moderate AR at 5 years (n = 125). Of the 860 patients with echocardiographic data or a reintervention after 30 days, there were 22 (2.6%) patients meeting the VARC-2 criteria for valve dysfunction and 10 (1.2%) patients with a reintervention >30 days. Conclusion: Five-year results in real-world, elderly, high-risk patients undergoing TAVI with a self-expanding bioprosthesis provided evidence for continued valve durability with low rates of reinterventions and haemodynamic valve dysfunction. Trial registration: ClinicalTrials.gov, NCT01074658

    A celebration of contemporany dance: Luces y sombras/Ligth and shadows

    No full text
    Programa de l'actuació celebrada el 26 de setembre de 200
    corecore