674 research outputs found
Recommended from our members
Projected WIMP sensitivity of the LUX-ZEPLIN dark matter experiment
LUX-ZEPLIN (LZ) is a next-generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with weakly interacting massive particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6-tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above 1.4Ă10-48 cm2 for a 40 GeV/c2 mass WIMP. Additionally, a 5Ï discovery potential is projected, reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of 2.3Ă10-43 cm2 (7.1Ă10-42 cm2) for a 40 GeV/c2 mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020
Recommended from our members
Erratum: Author Correction: Identification of genes required for eye development by high-throughput screening of mouse knockouts.
[This corrects the article DOI: 10.1038/s42003-018-0226-0.]
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle
interactions with a detector containing a total of 10 tonnes of liquid xenon
within a double-vessel cryostat. The large mass and proximity of the cryostat
to the active detector volume demand the use of material with extremely low
intrinsic radioactivity. We report on the radioassay campaign conducted to
identify suitable metals, the determination of factors limiting radiopure
production, and the selection of titanium for construction of the LZ cryostat
and other detector components. This titanium has been measured with activities
of U~1.6~mBq/kg, U~0.09~mBq/kg,
Th~~mBq/kg, Th~~mBq/kg, K~0.54~mBq/kg, and Co~0.02~mBq/kg (68\% CL).
Such low intrinsic activities, which are some of the lowest ever reported for
titanium, enable its use for future dark matter and other rare event searches.
Monte Carlo simulations have been performed to assess the expected background
contribution from the LZ cryostat with this radioactivity. In 1,000 days of
WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute
only a mean background of (stat)(sys) counts.Comment: 13 pages, 3 figures, accepted for publication in Astroparticle
Physic
A point-of-care clinical trial comparing insulin administered using a sliding scale versus a weight-based regimen
Background Clinical trials are widely considered
the gold standard in comparative effectiveness research (CER) but the high cost
and complexity of traditional trials and concerns about generalizability to
broad patient populations and general clinical practice limit their appeal.
Unsuccessful implementation of CER results limits the value of even the highest
quality trials. Planning for a trial comparing two standard strategies of
insulin administration for hospitalized patients led us to develop a new method
for a clinical trial designed to be embedded directly into the clinical care
setting thereby lowering the cost, increasing the pragmatic nature of the
overall trial, strengthening implementation, and creating an integrated
environment of research-based care
- âŠ