43 research outputs found

    Calibration and validation of the Mini-fiber EC image analysis instrument mean fiber diameter through direct or primary measurements

    Get PDF
    The Minifiber EC (MFEC) is a portable instrument for measuring the diameter of animal fibers. Its accuracy and precision have been estimated but by comparing its measurements with those of laboratory devices that had been calibrated on other devices in turn, not on a direct or primary measure of diameter. This work attempts to test direct measurements by gravimetry, Vernier mini caliper, microscope and the classic microprojector, using a non-deformable, high resistance synthetic fiber (Kevlar) for direct measurement. The MFEC instrument is calibrated with each mean fiber diameter obtained in direct measurements and its results are compared. The conclusions drawn are that it is possible to calibrate the MFEC instrument with direct measurements on Kevlar and measurement accuracy or tolerance of 0.28 microns is obtained. This indicates a very low biased mean fiber diameter measurement by MFEC

    Singularly Perturbed Monotone Systems and an Application to Double Phosphorylation Cycles

    Full text link
    The theory of monotone dynamical systems has been found very useful in the modeling of some gene, protein, and signaling networks. In monotone systems, every net feedback loop is positive. On the other hand, negative feedback loops are important features of many systems, since they are required for adaptation and precision. This paper shows that, provided that these negative loops act at a comparatively fast time scale, the main dynamical property of (strongly) monotone systems, convergence to steady states, is still valid. An application is worked out to a double-phosphorylation ``futile cycle'' motif which plays a central role in eukaryotic cell signaling.Comment: 21 pages, 3 figures, corrected typos, references remove

    Burkitt Lymphoma in Brazil Is Characterized by Geographically Distinct Clinicopathologic Features

    Get PDF
    Burkitt lymphoma (BL) is a highly aggressive non-Hodgkin lymphoma with a consistent MYC translocation. Epstein-Barr virus (EBV) has been associated with BL at different frequencies, depending on the clinical variant and geographic regions. This is a large-scale study of BL in Brazil, including 234 patients from 5 geographic regions that are widely disparate socioeconomically, including pediatric (61.1%) and adult (37.6%) populations. EBV was present in 52.6% of all BL cases, varying from 29% (12/42) in the South to 76% (13/17) in the North. Most of the cases were EBV type A. The frequency was higher in the pediatric group, and EBV association within this age range predominated in all regions except the South. Expression of p53 protein was observed in 16.2%, and only rare cases showed p63 expression. BL in Brazil is regionally distinct and has a low incidence of p53 overexpression and a higher-than-expected association with EBV in sporadic cases

    New-generation atrial antitachycardia pacing (Reactive ATP) is associated with reduced risk of persistent or permanent atrial fibrillation in patients with bradycardia: Results from the MINERVA randomized multicenter international trial

    Get PDF
    Background Atrial fibrillation (AF) is a frequent comorbidity in patients with pacemaker and is a recognized cause of mortality, morbidity, and quality-of-life impairment. The international MINimizE Right Ventricular pacing to prevent Atrial fibrillation and heart failure trial established that atrial preventive pacing and atrial antitachycardia pacing (DDDRP) in combination with managed ventricular pacing (MVP) reduce permanent AF occurrence in comparison with standard dual-chamber pacing (DDDR). Objective We aimed to determine the role of new-generation atrial antitachycardia pacing (Reactive ATP) in preventing AF disease progression. Methods Patients with dual-chamber pacemaker and with previous atrial tachyarrhythmias were randomly assigned to DDDR (n = 385 (33%)), MVP (n = 398 (34%)), or DDDRP+MVP (n = 383 (33%)) group. The incidence of permanent AF, as defined by the study investigator, or persistent AF, defined as ≥7 consecutive days with AF, was estimated using the Kaplan-Meier method, while its association with patients' characteristics was evaluated via multivariable Cox regression. Results At 2 years, the incidence of permanent or persistent AF was 26% (95% confidence interval [CI] 22%-31%) in the DDDR group, 25% (95% CI 21%-30%) in the MVP group, and 15% (95% CI 12%-20%) in the DDDRP+MVP group (P 44.4%) as a significant predictor of reduced permanent or persistent AF risk (hazard ratio 0.32; 95% CI 0.13-0.781; P =.012) and episodes' characteristics, such as long atrial arrhythmia cycle length, regularity, and the number of rhythm transitions, as predictors of high ATP efficacy. Conclusion In patients with bradycardia, DDDRP+MVP delays AF disease progression, with Reactive ATP efficacy being an independent predictor of permanent or persistent AF reduction
    corecore