684 research outputs found
Beam-ion transport dependence on Magnetic Perturbations spectrum and plasma helicity in the ASDEX Upgrade tokamak
EUROfusion Consortium 63305
Planck-LFI radiometers' spectral response
The Low Frequency Instrument (LFI) is an array of pseudo-correlation
radiometers on board the Planck satellite, the ESA mission dedicated to
precision measurements of the Cosmic Microwave Background. The LFI covers three
bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central
frequency.
The characterization of the broadband frequency response of each radiometer
is necessary to understand and correct for systematic effects, particularly
those related to foreground residuals and polarization measurements. In this
paper we present the measured band shape of all the LFI channels and discuss
the methods adopted for their estimation. The spectral characterization of each
radiometer was obtained by combining the measured spectral response of
individual units through a dedicated RF model of the LFI receiver scheme.
As a consistency check, we also attempted end-to-end spectral measurements of
the integrated radiometer chain in a cryogenic chamber. However, due to
systematic effects in the measurement setup, only qualitative results were
obtained from these tests. The measured LFI bandpasses exhibit a moderate level
of ripple, compatible with the instrument scientific requirements.Comment: 16 pages, 9 figures, this paper is part of the Prelaunch status LFI
papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jins
A systematic approach to the Planck LFI end-to-end test and its application to the DPC Level 1 pipeline
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the
handling of the scientific and housekeeping telemetry. It is a critical
component of the Planck ground segment which has to strictly commit to the
project schedule to be ready for the launch and flight operations. In order to
guarantee the quality necessary to achieve the objectives of the Planck
mission, the design and development of the Level 1 software has followed the
ESA Software Engineering Standards. A fundamental step in the software life
cycle is the Verification and Validation of the software. The purpose of this
work is to show an example of procedures, test development and analysis
successfully applied to a key software project of an ESA mission. We present
the end-to-end validation tests performed on the Level 1 of the LFI-DPC, by
detailing the methods used and the results obtained. Different approaches have
been used to test the scientific and housekeeping data processing. Scientific
data processing has been tested by injecting signals with known properties
directly into the acquisition electronics, in order to generate a test dataset
of real telemetry data and reproduce as much as possible nominal conditions.
For the HK telemetry processing, validation software have been developed to
inject known parameter values into a set of real housekeeping packets and
perform a comparison with the corresponding timelines generated by the Level 1.
With the proposed validation and verification procedure, where the on-board and
ground processing are viewed as a single pipeline, we demonstrated that the
scientific and housekeeping processing of the Planck-LFI raw data is correct
and meets the project requirements.Comment: 20 pages, 7 figures; this paper is part of the Prelaunch status LFI
papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jins
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
We give a description of the design, construction and testing of the 30 and
44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the
Planck mission to be launched in 2009. The scientific requirements of the
mission determine the performance parameters to be met by the FEMs, including
their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in
which the signal from the sky is compared with a 4-K blackbody load. The Low
Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High
Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel
phase-switch design which gives excellent amplitude and phase match across the
band.
The noise temperature requirements are met within the measurement errors at
the two frequencies. For the most sensitive LNAs, the noise temperature at the
band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively.
For some of the FEMs, the noise temperature is still falling as the ambient
temperature is reduced to 20 K. Stability tests of the FEMs, including a
measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all
critical aspects. The most sensitive LNAs have reached new limits of noise
temperature for HEMTs at their band centres. The FEMs have well-defined linear
polarization characteristcs.Comment: 39 pages, 33 figures (33 EPS files), 12 tables. Planck LFI technical
papers published by JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/1748-022
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.Comment: Accepted for publications in Astronomy and Astrophysics. Astronomy &
Astrophysics, 2010 (acceptance date: 12 Jan 2010
The linearity response of the Planck-LFI flight model receivers
In this paper we discuss the linearity response of the Planck-LFI receivers,
with particular reference to signal compression measured on the 30 and 44 GHz
channels. In the article we discuss the various sources of compression and
present a model that accurately describes data measured during tests performed
with individual radiomeric chains. After discussing test results we present the
best parameter set representing the receiver response and discuss the impact of
non linearity on in-flight calibration, which is shown to be negligible.Comment: this paper is part of the Prelaunch status LFI papers published on
JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst; This is an
author-created, un-copyedited version of an article accepted for publication
in JINST. IOP Publishing Ltd is not responsible for any errors or omissions
in this version of the manuscript or any version derived from it. The
definitive publisher authenticated version is available online at
10.1088/1748-0221/4/12/T12011
The European Photon Imaging Camera on XMM-Newton: The MOS Cameras
The EPIC focal plane imaging spectrometers on XMM-Newton use CCDs to record
the images and spectra of celestial X-ray sources focused by the three X-ray
mirrors. There is one camera at the focus of each mirror; two of the cameras
contain seven MOS CCDs, while the third uses twelve PN CCDs, defining a
circular field of view of 30 arcmin diameter in each case. The CCDs were
specially developed for EPIC, and combine high quality imaging with spectral
resolution close to the Fano limit. A filter wheel carrying three kinds of
X-ray transparent light blocking filter, a fully closed, and a fully open
position, is fitted to each EPIC instrument. The CCDs are cooled passively and
are under full closed loop thermal control. A radio-active source is fitted for
internal calibration. Data are processed on-board to save telemetry by removing
cosmic ray tracks, and generating X-ray event files; a variety of different
instrument modes are available to increase the dynamic range of the instrument
and to enable fast timing. The instruments were calibrated using laboratory
X-ray beams, and synchrotron generated monochromatic X-ray beams before launch;
in-orbit calibration makes use of a variety of celestial X-ray targets. The
current calibration is better than 10% over the entire energy range of 0.2 to
10 keV. All three instruments survived launch and are performing nominally in
orbit. In particular full field-of-view coverage is available, all electronic
modes work, and the energy resolution is close to pre-launch values. Radiation
damage is well within pre-launch predictions and does not yet impact on the
energy resolution. The scientific results from EPIC amply fulfil pre-launch
expectations.Comment: 9 pages, 11 figures, accepted for publication in the A&A Special
Issue on XMM-Newto
- …