11 research outputs found
Digital chest radiography: an update on modern technology, dose containment and control of image quality
The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems
Letter to the Editor Re: “Optimizing the Use of Computer Radiography in Pediatric Chest Imaging”
Umformen von metallischen Werkstoffen durch Impulsmagnetfelder Abschlussbericht
Available from TIB Hannover: RO 146(158) / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEArbeitsgemeinschaft Industrieller Forschungsvereinigungen 'Otto von Guericke' e.V. (AIF), Koeln (Germany); Bundesministerium fuer Wirtschaft und Technologie (BMWi), Berlin (Germany)DEGerman
Optimising the Use of Computed Radiography in Pediatric Chest Imaging
The objective of this study was to analyze image quality of chest examinations in pediatric patients using computed radiography (CR) obtained with a wide range of doses to suggest the appropriate parameters for optimal image quality. A sample of 240 chest images in four age ranges was randomly selected from the examinations performed during 2004. Images were obtained using a CR system and were evaluated independently by three radiologists. Each image was scored using criteria proposed by the European Guidelines on Quality Criteria in Pediatrics. Mean global scoring and scoring of individual criteria more sensitive to noise were used to evaluate image quality. Agfa dose level (DL) was in the range 1.20 to 2.85. It was found that there was not significant correlation (R < 0.5) between image quality and DL for any of the age ranges for either global score or for individual criteria more related to noise. The mean value of DL was in the ranges 1.9–2.1 for the four age bands. From this study, a DL value of 1.6 is proposed for pediatric CR chest imaging. This could yield a reduction of approximately a factor of 2.5 in mean patient entrance surface doses