    Management of the Investigation and Detection of Legionellosis Agent in the Environmental Samples during the Preparation and Holding of the XXII Winter Olympics and XI Paralympics in Sochi

    Get PDF
    Provided are the data on the management and carrying out of the laboratory control over the hot-water supply systems of the sports venues and accommodation areas for the presence of Legionella pneumophila during the XXII Olympics and XI Paralympics in Sochi, 2014. Inspected have been 105 facilities. The samples from 37 of them showed positive. L. pneumophila DNA concentration varies between 2.19路102 and 3.92路107 genome equivalents (g.e.)/l. By means of bacteriological investigation detected have been legionella colonies in the water supply systems of 16 facilities, at one of the items - the loading is over 1路104 colony-forming units/l. Performed has been comparative analysis of the results obtained using PCR assay and bacteriological test. Based on the genotyping of 7 isolated strains serogroup 1 and 2 strains of 2-14 serogroups it is concluded that L. pneumophila strains circulating in the resort town Sochi are genetically heterogeneous

    Providing Laboratory Monitoring of Environmental Objects During the XXII Olympic Winter Games and XI Paralympic Winter Games in Sochi

    Get PDF
    The organization of laboratory environmental monitoring in the pre-Olympic period and during the XXII Olympic winter games and XI Paralympic winter games 2014. The results of radiation monitoring during the construction of sports and infrastructure facilities Sochi. Study analyzed the procedure for compliance with hygienic standards and additional indicators of drinking water, food, food raw material and other objects