19 research outputs found

    Percutaneous reduction and fixation of an intra-articular calcaneal fracture using an inflatable bone tamp: description of a novel and safe technique

    Get PDF
    Calcaneal fractures are common injuries involving the hind foot and often a source of significant long-term morbidity. Treatment options have changed throughout the ages from periods of preferred nonoperative management to closed reduction with a mallet, and more recently, open reduction and anatomic internal fixation. The current treatment of choice; however, is often debated, as open management of these fractures carries many risks to include wound breakdown and infection. A less invasive form of surgical management through small incisions, while maintaining the ability to obtain joint congruency, anatomic alignment, and restore calcaneal height and width would be ideal. We propose a novel form of fracture reduction using an inflatable bone tamp and percutaneous fracture fixation. Preoperative planning and experienced fluoroscopy is crucial to successful management using this method. Although we achieved successful radiographic outcome in this case, long-term functional outcome of this technique are yet to be published

    Modality of wound closure after total knee replacement: are staples as safe as sutures? A retrospective study of 181 patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Surgical site wound closure plays a vital role in post-operative success. This effect is magnified in regard to commonly performed elective procedures such as total knee arthroplasty. The use of either sutures or staples for skin re-approximation remains a contested subject, which may have a significant impact on both patient safety and surgical outcome. The literature remains divided on this topic.</p> <p>Methods</p> <p>Two cohorts of patients at a level one trauma and regional referral center were reviewed. Cohorts consisted of consecutive total knee arthroplasties performed by two surgeons who achieved surgical wound re-approximation by either staples or absorbable subcuticular sutures. Outcome variables included time of surgery, wound dehiscence, surgical site infection per Center for Disease Control criteria and repeat procedures for debridement and re-closure.</p> <p>Results</p> <p>181 patients qualified for study inclusion. Staples were employed in 82 cases (45.3% of total) and sutures in 99 cases (54.7%). The staples group had no complications while the sutures group had 9 (9.1%). These consisted of: 4 infections (2 superficial, one deep, one organ/space); three patients required re-suturing for dehiscence; one allergic type reaction to suture material; and one gout flare resulting in dehiscence. The mean surgical time with sutures was 122.3 minutes (sd = 33.4) and with staples was 114 minutes (sd = 24.4).</p> <p>Conclusion</p> <p>This study demonstrated significantly fewer complications with staple use than with suture use. While all complications found in this study cannot be directly attributed to skin re-approximation method, the need for further prospective, randomized trials is established.</p

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Incidence and pattern of technical complications in balloon-guided osteoplasty for depressed tibial plateau fractures: a pilot study in 20 consecutive patients

    Get PDF
    BACKGROUND: Inflation bone tamps are becoming increasingly popular as a reduction tool for depressed tibial plateau fractures. A number of recent publications have addressed the technical aspects of balloon inflation osteoplasty. However, no study has yet been published to describe the technical limitations, intraoperative complications, and surgical bailout strategies for this new technology. METHODS: Observational retrospective study of all patients managed with inflatable bone tamps for depressed tibial plateau fractures between October 1, 2010 and December 1, 2012. The primary outcome parameter was the rate of complications, which were stratified into “minor” and “major” depending on the necessity for altering the surgical plan intraoperatively, and based on the risk for patient harm. This study was approved by the Institutional Review Board of the State of Colorado. RESULTS: A consecutive series of 20 patients were managed by balloon inflation osteoplasty for depressed tibial plateau fractures during the 15 months study period. The mean age was 42.8 years (range 20–79), with 9 females and 11 males. A total of 13 patients sustained an adverse intraoperative event (65%), with three patients sustaining multiple technical complications. Minor events (n = 8) included the burst of a balloon with extrusion of contrast dye, and the unintentional posterior wall displacement during balloon inflation. Major events (n = 5) included the intra-articular injection of calcium phosphate in the knee joint, and the inability to elevate the depressed articular fragment with the inflatable bone tamp. CONCLUSION: The observed intraoperative complication rate of 65% reflects a steep learning curve for the use of inflation bone tamps to reduce depressed tibial plateau fractures. Specific surgical bailout options are provided in this article, based on our early anecdotal experience in a pilot series of 20 consecutive cases. Patients should be advised on the benefits and risks of this new technology as part of the shared decision-making process during the informed consent

    Influence of shockwave profile on ejection of micron-scale material from shocked Sn surfaces: an experimental study

    No full text
    This effort experimentally investigates the relationship between shock-breakout pressure and the amount of micron-scale fragments ejected (ejecta) upon shock release at the metal/vacuum interface of Sn targets shocked with a supported shockwave. The results are compared with an analogous set derived from HE shocked Sn targets, Taylor shockwave loading. The supported shock-pulse was created by impacting a Sn target with a Ti64 (Ti-6Al-4V) impactor that was accelerated using a powder gun. Ejecta production at the free-surface or back-side of the Sn targets were characterized through use of piezoelectric pins and Asay foils, and heterodyne velocimetry verified the time of shock release and the breakout pressure
    corecore