1,087 research outputs found

    Development of Aluminum LEKIDs for Balloon-Borne Far-IR Spectroscopy

    Get PDF
    We are developing lumped-element kinetic inductance detectors (LEKIDs) designed to achieve background-limited sensitivity for far-infrared (FIR) spectroscopy on a stratospheric balloon. The Spectroscopic Terahertz Airborne Receiver for Far-InfraRed Exploration (STARFIRE) will study the evolution of dusty galaxies with observations of the [CII] 158 μ\mum and other atomic fine-structure transitions at z=0.51.5z=0.5-1.5, both through direct observations of individual luminous infrared galaxies, and in blind surveys using the technique of line intensity mapping. The spectrometer will require large format (\sim1800 detectors) arrays of dual-polarization sensitive detectors with NEPs of 1×10171 \times 10^{-17} W Hz1/2^{-1/2}. The low-volume LEKIDs are fabricated with a single layer of aluminum (20 nm thick) deposited on a crystalline silicon wafer, with resonance frequencies of 100250100-250 MHz. The inductor is a single meander with a linewidth of 0.4 μ\mum, patterned in a grid to absorb optical power in both polarizations. The meander is coupled to a circular waveguide, fed by a conical feedhorn. Initial testing of a small array prototype has demonstrated good yield, and a median NEP of 4×10184 \times 10^{-18} W Hz1/2^{-1/2}.Comment: accepted for publication in Journal of Low Temperature Physic

    Use of MMG signals for the control of powered orthotic devices: Development of a rectus femoris measurement protocol

    Get PDF
    Copyright © 2009 Rehabilitation Engineering and Assistive Technology Society (RESNA). This is an Author's Accepted Manuscript of an article published in Assistive Technology, 21(1), 1 - 12, 2009, copyright Taylor & Francis, available online at: http://www.tandfonline.com/10.1080/10400430902945678.A test protocol is defined for the purpose of measuring rectus femoris mechanomyographic (MMG) signals. The protocol is specified in terms of the following: measurement equipment, signal processing requirements, human postural requirements, test rig, sensor placement, sensor dermal fixation, and test procedure. Preliminary tests of the statistical nature of rectus femoris MMG signals were performed, and Gaussianity was evaluated by means of a two-sided Kolmogorov-Smirnov test. For all 100 MMG data sets obtained from the testing of two volunteers, the null hypothesis of Gaussianity was rejected at the 1%, 5%, and 10% significance levels. Most skewness values were found to be greater than 0.0, while all kurtosis values were found to be greater than 3.0. A statistical convergence analysis also performed on the same 100 MMG data sets suggested that 25 MMG acquisitions should prove sufficient to statistically characterize rectus femoris MMG. This conclusion is supported by the qualitative characteristics of the mean rectus femoris MMG power spectral densities obtained using 25 averages

    The design and characterization of a 300 channel, optimized full-band millimeter filterbank for science with SuperSpec

    Get PDF
    SuperSpec is an integrated, on-chip spectrometer for millimeter and sub-millimeter astronomy. We report the approach, design optimization, and partial characterization of a 300 channel filterbank covering the 185 to 315 GHz frequency band that targets a resolving power R ~ 310, and fits on a 3.5×5.5 cm chip. SuperSpec uses a lens and broadband antenna to couple radiation into a niobium microstrip that feeds a bank of niobium microstrip half-wave resonators for frequency selectivity. Each half-wave resonator is coupled to the inductor of a titanium nitride lumped-element kinetic inductance detector (LEKID) that detects the incident radiation. The device was designed for use in a demonstration instrument at the Large Millimeter Telescope (LMT)

    Full-Array Noise Performance of Deployment-Grade SuperSpec mm-Wave On-Chip Spectrometers

    Get PDF
    SuperSpec is an on-chip filter bank spectrometer designed for wideband moderate-resolution spectroscopy at millimeter wavelengths, employing TiN kinetic inductance detectors. SuperSpec technology will enable large-format spectroscopic integral field units suitable for high-redshift line intensity mapping and multi-object spectrographs. In previous results, we have demonstrated noise performance in individual detectors suitable for photon noise-limited ground-based observations at excellent mm-wave sites. In these proceedings, we present the noise performance of a full R∼275 spectrometer measured using deployment-ready RF hardware and software. We report typical noise equivalent powers through the full device of ∼3×10⁻¹⁶ W Hz^(−1/2) at expected sky loadings, which are photon noise dominated. Based on these results, we plan to deploy a six-spectrometer demonstration instrument to the Large Millimeter Telescope in early 2020

    Ursodeoxycholic acid to reduce adverse perinatal outcomes for intrahepatic cholestasis of pregnancy: the PITCHES RCT

    Get PDF
    Background: Intrahepatic cholestasis of pregnancy, characterised by maternal pruritus and raised serum bile acid concentrations, is associated with increased rates of stillbirth, preterm birth and neonatal unit admission. Ursodeoxycholic acid is widely used as a treatment, but without an adequate evidence base. / Objective: We aimed to evaluate whether or not ursodeoxycholic acid reduces adverse perinatal outcomes in affected women. / Design: Multicentre, masked, randomised, placebo-controlled, two-arm, parallel-group trial. / Setting: Thirty-three UK maternity units. / Participants: Women with intrahepatic cholestasis of pregnancy aged ≥ 18 years, between 20+0 and 40+6 weeks’ gestation with a singleton or twin pregnancy and no known lethal fetal anomaly. / Interventions: Women were randomly assigned (1 : 1 allocation ratio) to take ursodeoxycholic acid tablets or matched placebo tablets, at an equivalent dose of 1000 mg daily, titrated as needed. / Main outcome measures: The primary outcome was a composite of perinatal death (in utero fetal death after randomisation or known neonatal death up to 7 days) or preterm delivery (< 37 weeks’ gestation) or neonatal unit admission for at least 4 hours (from birth until hospital discharge). Each infant was counted once within this composite. Analyses were by intention to treat. / Results: Between 23 December 2015 and 7 August 2018, 605 women were randomised, with 305 women allocated to the ursodeoxycholic acid arm and 300 women to the placebo arm. There was no evidence of a significant difference in the incidence of the primary outcome between the groups: 23.0% (74 out of 322 infants) in the ursodeoxycholic acid group compared with 26.7% (85 out of 318 infants) in the placebo group; adjusted risk ratio 0.85 (95% confidence interval 0.62 to 1.15). There was no evidence of a significant difference in total costs (maternal, infant and the cost of ursodeoxycholic acid) between the two trial groups. There were two serious adverse events in the ursodeoxycholic acid group and six in the placebo group. / Limitations: Limitations include a primary outcome event rate in the control group that was lower than that estimated for the sample size calculation, but the lack of evidence of effect in all analyses suggests that it is unlikely that the trial had insufficient power. / Conclusions: In this clinical trial of ursodeoxycholic acid in women with intrahepatic cholestasis of pregnancy, there is no evidence that it is effective in reducing a composite of adverse perinatal outcomes. / Future work: Future research should aim to elucidate the aetiology and pathophysiology of adverse perinatal outcomes, particularly stillbirth, in women with intrahepatic cholestasis of pregnancy to assist the development of an effective preventative treatment. Further exploratory analyses may identify groups of women who might respond to ursodeoxycholic acid treatment. / Trial registration: Current Controlled Trials ISRCTN91918806. / Funding: This project was funded by the Efficacy and Mechanism Evaluation (EME) Programme, a Medical Research Council and National Institute for Health Research (NIHR) partnership. This will be published in full in Efficacy and Mechanism Evaluation; Vol. 7, No. 9. See the NIHR Journals Library website for further project information

    Identification of guinea pig remains in the Pucará de Tilcara (Jujuy, Argentina): Evidence in favour of the presence of the Andean breed in the Quebrada de Humahuaca

    Get PDF
    In this article, we identified rodent remains found in the Pucará de Tilcara, an archaeological site from the Argentine Northwest that was occupied by humans from 1,100 ad until the Spanish conquest. The zooarchaeological analyses were carried out using anatomical descriptions and geometric morphometric analyses of the dorsal and ventral views of mandibular remains. The results and the archaeological context discussed showed that all the rodent remains could correspond to the Andean breed of domestic guinea pigs. The combination of the methods used here gave us a strong support to the taxonomical assignment. The presence of domestic guinea pigs in archaeological sites of the northwestern Argentina was never proposed. This approach allowed us to increase knowledge about the distribution of caviines in the region, and their relationship to anthropic processes.Fil: Lopez Geronazzo, Lautaro Nahuel. Universidad Nacional de Jujuy. Instituto de Ecorregiones Andinas. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Ecorregiones Andinas; ArgentinaFil: Otero, Clarisa. Universidad Nacional de Jujuy. Instituto de Ecorregiones Andinas. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Ecorregiones Andinas; Argentina. Universidad de Buenos Aires. Facultad de Filosofía y Letras; ArgentinaFil: Alvarez, Alicia. Universidad Nacional de Jujuy. Instituto de Ecorregiones Andinas. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Ecorregiones Andinas; Argentina. Universidad Nacional de Jujuy. Instituto de Geología Minera; ArgentinaFil: Ercoli, Marcos Darío. Universidad Nacional de Jujuy. Instituto de Ecorregiones Andinas. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Ecorregiones Andinas; Argentina. Universidad Nacional de Jujuy. Instituto de Geología Minera; ArgentinaFil: Cortés Delgado, Natalia. University of Illinois; Estados Unido

    Radiation damage in the LHCb vertex locator

    Get PDF
    The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately 45 × 1012 1 MeV neutron equivalent (1 MeV neq). At the operational sensor temperature of approximately −7 °C, the average rate of sensor current increase is 18 μA per fb−1, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of Eg = 1.16±0.03±0.04 eV obtained. The first observation of n+-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around 15 × 1012 of 1 MeV neq. The only n+-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately 3 × 1012 1 MeV neq, a decrease in the Effective Depletion Voltage (EDV) of around 25 V is observed. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n+-on-n type sensors, with rates of (1.43±0.16) × 10−12 V/ 1 MeV neq and (1.35±0.25) × 10−12 V/ 1 MeV neq measured for n+-on-p and n+-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed

    Mouse transcriptome reveals potential signatures of protection and pathogenesis in human tuberculosis

    Get PDF
    Although mouse infection models have been extensively used to study the host response to Mycobacterium tuberculosis, their validity in revealing determinants of human tuberculosis (TB) resistance and disease progression has been heavily debated. Here, we show that the modular transcriptional signature in the blood of susceptible mice infected with a clinical isolate of M. tuberculosis resembles that of active human TB disease, with dominance of a type I interferon response and neutrophil activation and recruitment, together with a loss in B lymphocyte, natural killer and T cell effector responses. In addition, resistant but not susceptible strains of mice show increased lung B cell, natural killer and T cell effector responses in the lung upon infection. Notably, the blood signature of active disease shared by mice and humans is also evident in latent TB progressors before diagnosis, suggesting that these responses both predict and contribute to the pathogenesis of progressive M. tuberculosis infection

    Precision luminosity measurements at LHCb

    Get PDF
    Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy √s. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for √s = 2.76, 7 and 8 TeV (proton-proton collisions) and for √sNN = 5 TeV (proton-lead collisions). Both the "van der Meer scan" and "beam-gas imaging" luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves significantly the consistency of the results. For proton-proton interactions at √s = 8 TeV a relative precision of the luminosity calibration of 1.47% is obtained using van der Meer scans and 1.43% using beam-gas imaging, resulting in a combined precision of 1.12%. Applying the calibration to the full data set determines the luminosity with a precision of 1.16%. This represents the most precise luminosity measurement achieved so far at a bunched-beam hadron collider
    corecore