13 research outputs found

    The physiological burden of the 6-minute walk test compared with cardiopulmonary exercise stress test in patients with severe aortic atenosis

    Get PDF
    Background Management of aortic stenosis (AS) relies on symptoms. Exercise testing is recommended for asymptomatic patients with significant AS but is often experienced as forbidding and/or technically unrealistic for patients who are often frail, deconditioned, and intimidated by the exercise test. We compared the physiological burden assessed with gas exchange assessments to gauge and respiratory exchange ratio (RER) of a 6-minute walk test (6MWT) to a cardiopulmonary exercise stress test (CPET) in patients with severe AS. peak oxygen utilization Methods Adults with equivocal symptoms and severe AS (1-aortic valve area [AVA] ≤ 1.0 cm2 or AVA index ≤ 0.6 cm2/m2, 2-peak aortic jet velocity ≥ 4.0 m/sec, 3-mean transvalvular pressure gradient ≥ 40 mm Hg by rest or dobutamine stress echocardiography, or 4-aortic valve calcification ≥ 1200 in women or ≥ 2000 AU in men) were studied. All participants completed both a 6MWT and symptom-limited progressive bicycle exercise testing. Breath-by-breath gas analysis and 12-lead electrocardiography were completed during 6MWT and CPET. Results: Eleven patients were studied. Patients walked on average 330 ± 75 m during the 6MWT and achieved a maximal workload of 48 ± 14 watts during the CPET. During the 6MWT, peak maximal oxygen uptake (O2peak) was 12.8 ± 2.5 vs 10.8 ± 4.2 mL/kg/min during the CPET. Respiratory exchange ratio exceeded 1.1 in both the 6MWT and CPET indicating similarly high exertion. Compared with the CPET, a larger proportion of the 6MWT was performed at a high intensity level (78% ± 28% vs 33% ± 24% at > 85% V̇O2peak; P = 0.004). Conclusions The 6MWT with breath-by-breath gas analysis was well tolerated and able to achieve a physiological intense RER and O2peak that are similar to symptom-limited CPET in patients with severe AS.Introduction La prise en charge de la sténose aortique (SA) dépend des symptômes. L’épreuve d’effort est recommandée aux patients asymptomatiques qui ont une SA significative, mais elle est souvent perçue comme dangereuse et/ou théoriquement irréaliste chez ces patients qui sont souvent fragiles, en mauvaise forme et craintifs par l’épreuve d’effort. Nous avons comparé le fardeau physiologique calculé par la consommation maximale de l’oxygène (O2max) et le quotient respiratoire (QR) d’un test de marche de 6 minutes (TM6) et d'une épreuve d’effort maximal chez des patients avec une SA sévère. Méthodes Tous les patients présentaient une SA symptomatique et sévère (1-aire valvulaire aortique [AVA] ≤ 1,0 cm2 ouAVA ≤ 0,6 cm2/m2, 2-une vélocité maximale du flux aortique ≥ 4,0 m/sec, 3-un gradient de pression transvalvulaire moyen ≥ 40 mmHg au repos ou à l’échocardiographie à l’effort sous dobutamine ou 4-une calcification valvulaire aortique (AU) ≥ 1200 chez les femmes ou ≥ 2000 AU chez les hommes). Les participants ont effectué un TM6 et une ’épreuve d’effort maximal de type rampe sur vélo. L’analyse des échanges gazeux respiration par respiration et un électrocardiogramme à 12 dérivations ont été effectués durant le TM6 et l'épreuve d'effort maximal. Résultats Un total de 11 patients ont participé à l'étude. Les patients ont marché en moyenne 330 ± 75 m durant le TM6 et ont atteint une charge de travail maximale de 48 ± 14 watts durant l’épreuve d'effort maximal. Durant le TM6, le O2max était de 12,8 ± 2,5 vs 10,8 ± 4,2 ml/kg/min durant l’épreuve d'effort maximal. Le QR était supérieur à 1,1 au TM6 ainsi qu'à l’épreuve d'effort maximal. Comparativement à l’épreuve d'effort maximal, un pourcentage plus important au TM6 a été réalisée à une intensité élevée (78 % ± 28 % vs 33 % ± 24 % à > 85 % V̇O2max; P = 0,004). Conclusions Le TM6 avec mesure directe des échanges gazeux était bien toléré et susceptible d’atteindre des valeurs physiologiques d'intensité élevée pour le QR et le O2max. Les valeurs atteintes au TM6 étaient semblables à celles de l'épreuve d'effort maximal chez les patients avec une SA sévère

    Methods for sea ice indentation tests

    No full text
    The test apparatus and detailed methodology to perform indentation tests on sea ice in the field are described in this report.NRC publication: Ye

    The effects of tidal jacking on ice displacement and strain in the nearshore environment

    No full text
    Observations on the nearshore movement of an ice cover were made at two locations in the North Baffin Area of the Canadian Arctic. These measurements were made at half hourly and hourly intervals for periods up to 24 hours. From these measurements, a consistent pattern of offshore ice cover movement has been observed. This has been related to a concommittant lateral shortening of the ice sheet itself. These short term measurements tend to support a tidal jacking mechanism as the cause of the observed movements.Le pr\ue9sent document examine les contraintes exerc\ue9es par la glace et les facteurs environnementaux au quai de Nanisivik en bordure du d\ue9troit de Strathcona, dans l'Arctique canadien, pendant l'hiver de 1985-1986. Le r\ue9gime glaciaire est caract\ue9ris\ue9 par la formation de glace de rive de premi\ue8re ann\ue9e qui atteint une \ue9paisseur maximale de 1,6 m en mai. Le m\ue9canisme premier de l'apparition de charges engendr\ue9es par la glace \ue0 cet endroit semble \ueatre les d\ue9formations de la couverture de glace attribuables aux variations de temp\ue9rature. Une analyse thermique bas\ue9e sur le comportement du fluage secondaire pr\ue9dit des contraintes thermiques inf\ue9rieures \ue0 celles mesur\ue9es.Peer reviewed: YesNRC publication: Ye

    Small scale field indentation tests on first year sea ice

    No full text
    A series of indentation tests were performed on first year sea ice. Flat and hemispherical indentor heads were forced into a semi-infinite vertical ice wall. The tests were conducted at high loading rates and brittle ice failure predominates. The results of the tests are presented and penetration and contact factors are discussed in terms of failure modes observed.NRC publication: Ye

    Hypertrophy dependent doubling of L-cells in Roux-en-Y gastric bypass operated rats

    Get PDF
    BACKGROUND AND AIMS: Roux-en-Y gastric bypass (RYGB) leads to a rapid remission of type 2 diabetes mellitus (T2DM), but the underlying mode of action remains incompletely understood. L-cell derived gut hormones such as glucagon-like peptide-1 (GLP-1) and peptide YY (PYY) are thought to play a central role in the anti-diabetic effects of RYGB; therefore, an improved understanding of intestinal endocrine L-cell adaptability is considered pivotal. METHODS: The full rostrocaudal extension of the gut was analyzed in rats after RYGB and in sham-operated controls ad libitum fed or food restricted to match the body weight of RYGB rats. Total number of L-cells, as well as regional numbers, densities and mucosa volumes were quantified using stereological methods. Preproglucagon and PYY mRNA transcripts were quantified by qPCR to reflect the total and relative hormone production capacity of the L-cells. RESULTS: RYGB surgery induced hypertrophy of the gut mucosa in the food exposed regions of the small intestine coupled with a doubling in the total number of L-cells. No changes in L-cell density were observed in any region regardless of surgery or food restriction. The total gene expression capacity of the entire gut revealed a near 200% increase in both PYY and preproglucagon mRNA levels in RYGB rats associated with both increased L-cell number as well as region-specific increased transcription per cell. CONCLUSIONS: Collectively, these findings indicate that RYGB in rats is associated with gut hypertrophy, an increase in L-cell number, but not density, and increased PYY and preproglucagon gene expression. This could explain the enhanced gut hormone dynamics seen after RYGB
    corecore