128 research outputs found

    High power conical-shaped Niobium targets for reliable [18F-] production and lower [18O] water consumption: High power conical-shaped Niobium targets for reliable [18F-] production and lower [18O] water consumption

    Get PDF
    Introduction In order to address the increasing demand for Fluorine-18 and the rising cost per mL of 18O enriched water, IBA developed improvements to their 18F- production systems. For this new design we started from scratch, with the main objectives of reducing the required enriched water volume and improving the cooling of the insert. A better cooling allows increasing the target current and thus the produced activity. Finally, we aimed to reduce the number of parts and improve the design of auxiliary components. Material and Methods Six Niobium conical inserts with different target chamber volumes were machined and tested. Only 4 of these were selected to create the new range of IBA 18F− targets shown in TABLE 1. The new Niobium target inserts have a complex shape with drilled channels on the outside of the chamber and a deep channel next to the beam strike area (FIG. 1, green circle) to ensure efficient cooling. The 18O water inlet lines are now directly inserted in the Niobium body (FIG. 1, blue circle) to improve 18F- quality (no more contact with small o-rings). In operation, a 35µm Havar® target window is used. All tests were performed using IBA Cyclone® 18 cyclotron. The targets were filled with different volumes of enriched 18O water (enrichment > 92 %) and irradiated with 18 MeV protons on target with beam currents up to 145 μA for 30 to 150 minutes, while the internal pressure rise of the target was recorded. For each target, a pressure-current curve was plotted and an optimum balance between target water fill volume, pressure and current has been determined, which maximises available activity after two hours, in each case. Results and Conclusion Radionuclidic impurities were measured and more than 100 FDG syntheses on various synthesizers confirmed the effectiveness of the new design. Increasing the current up to 145µA in Conical 16, the production reached 18 Ci in 2 hours, single beam, with a target pressure under 43 bar. Today, the use of these new targets for daily commercial production is increasing within the IBA Cyclone® installed base

    Modern non-invasive diagnosis of endometriosis

    Get PDF
    The purpose of the literature review was to summarize the current data on promising noninvasive markers of endometriosis determined in various biological media.Цель работы − обобщить современные данные о перспективных неинвазивных маркерах эндометриоза, определяемых в различных биологических средах

    3D Variation in delineation of head and neck organs at risk

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Consistent delineation of patient anatomy becomes increasingly important with the growing use of highly conformal and adaptive radiotherapy techniques. This study investigates the magnitude and 3D localization of interobserver variability of organs at risk (OARs) in the head and neck area with application of delineation guidelines, to establish measures to reduce current redundant variability in delineation practice.</p> <p>Methods</p> <p>Interobserver variability among five experienced radiation oncologists was studied in a set of 12 head and neck patient CT scans for the spinal cord, parotid and submandibular glands, thyroid cartilage, and glottic larynx. For all OARs, three endpoints were calculated: the Intraclass Correlation Coefficient (ICC), the Concordance Index (CI) and a 3D measure of variation (3D SD).</p> <p>Results</p> <p>All endpoints showed largest interobserver variability for the glottic larynx (ICC = 0.27, mean CI = 0.37 and 3D SD = 3.9 mm). Better agreement in delineations was observed for the other OARs (range, ICC = 0.32-0.83, mean CI = 0.64-0.71 and 3D SD = 0.9-2.6 mm). Cranial, caudal, and medial regions of the OARs showed largest variations. All endpoints provided support for improvement of delineation practice.</p> <p>Conclusions</p> <p>Variation in delineation is traced to several regional causes. Measures to reduce this variation can be: (1) guideline development, (2) joint delineation review sessions and (3) application of multimodality imaging. Improvement of delineation practice is needed to standardize patient treatments.</p

    Molecular analysis of enrichment cultures of ammonia oxidizers from the Salar de Huasco, a high altitude saline wetland in northern Chile

    Get PDF
    We analyzed enrichment cultures of ammonia-oxidizing bacteria (AOB) collected from different areas of Salar de Huasco, a high altitude, saline, pH-neutral water body in the Chilean Altiplano. Samples were inoculated into mineral media with 10 mM NH4+ at five different salt concentrations (10, 200, 400, 800 and 1,400 mM NaCl). Low diversity (up to three phylotypes per enrichment) of beta-AOB was detected using 16S rDNA and amoA clone libraries. Growth of beta-AOB was only recorded in a few enrichment cultures and varied according to site or media salinity. In total, five 16S rDNA and amoA phylotypes were found which were related to Nitrosomonas europaea/Nitrosococcus mobilis, N. marina and N. communis clusters. Phylotype 1-16S was 97% similar with N. halophila, previously isolated from Mongolian soda lakes, and phylotypes from amoA sequences were similar with yet uncultured beta-AOB from different biofilms. Sequences related to N. halophila were frequently found at all salinities. Neither gamma-AOB nor ammonia-oxidizing Archaea were recorded in these enrichment cultures

    Automated detection and segmentation of non-small cell lung cancer computed tomography images.

    Full text link
    peer reviewedDetection and segmentation of abnormalities on medical images is highly important for patient management including diagnosis, radiotherapy, response evaluation, as well as for quantitative image research. We present a fully automated pipeline for the detection and volumetric segmentation of non-small cell lung cancer (NSCLC) developed and validated on 1328 thoracic CT scans from 8 institutions. Along with quantitative performance detailed by image slice thickness, tumor size, image interpretation difficulty, and tumor location, we report an in-silico prospective clinical trial, where we show that the proposed method is faster and more reproducible compared to the experts. Moreover, we demonstrate that on average, radiologists & radiation oncologists preferred automatic segmentations in 56% of the cases. Additionally, we evaluate the prognostic power of the automatic contours by applying RECIST criteria and measuring the tumor volumes. Segmentations by our method stratified patients into low and high survival groups with higher significance compared to those methods based on manual contours

    FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0

    Get PDF
    The aim of this guideline is to provide a minimum standard for the acquisition and interpretation of PET and PET/CT scans with [18F]-fluorodeoxyglucose (FDG). This guideline will therefore address general information about [18F]-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET/CT) and is provided to help the physician and physicist to assist to carrying out, interpret, and document quantitative FDG PET/CT examinations, but will concentrate on the optimisation of diagnostic quality and quantitative information
    corecore