4,074 research outputs found

    Past electron-positron g-2 experiments yielded sharpest bound on CPT violation for point particles

    Full text link
    In our past experiments on a single electron and positron we measured the cyclotron and spin-cyclotron difference frequencies omega_c and omega_a and the ratios a = omega_a/ omega_c at omega_c = 141 Ghz for e^- and e^+ and later, only for e^-, also at 164 Ghz. Here, we do extract from these data, as had not done before, a new and very different figure of merit for violation of CPT symmetry, one similar to the widely recognized impressive limit |m_Kaon - m_Antikaon|/m_Kaon < 10^-18 for the K-mesons composed of two quarks. That expression may be seen as comparing experimental relativistic masses of particle states before and after the C, P, T operations had transformed particle into antiparticle. Such a similar figure of merit for a non-composite and quite different lepton, found by us from our Delta a = a^- - a^+ data, was even smaller, h_bar |omega_a^- - omega_a^+|/2m_0 c^2 = |Delta a| h_bar omega_c/2m_0 c^2) < 3(12) 10^-22.Comment: Improved content, Editorially approved for publication in PRL, LATEX file, 5 pages, no figures, 16

    Служение как принцип гуманитарного образования

    Full text link
    Presented the interpretation of service on N. A. Berdyaev in the context of the author's conception of therapeologyПредставлена интерпретация служения по Н. А. Бердяеву в контексте авторской концепции терапеологи

    Glucose availability and sensitivity to anoxia of isolated rat peripheral nerve

    Get PDF
    The contrast between resistance to ischemia and ischemic lesions in peripheral nerves of diabetic patients was explored by in vitro experiments. Isolated and desheathed rat peroneal nerves were incubated in the following solutions with different glucose availability: 1) 25 mM glucose, 2) 2.5 mM glucose, and 3) 2.5 mM glucose plus 10 mM 2-deoxy-D-glucose. Additionally, the buffering power of all of these solutions was modified. Compound nerve action potential (CNAP), extracellular pH, and extracellular potassium activity (aKe) were measured simultaneously before, during, and after a period of 30 min of anoxia. An increase in glucose availability led to a slower decline in CNAP and to a smaller rise in aKe during anoxia. This resistance to anoxia was accompanied by an enhanced extracellular acidosis. Postanoxic recovery of CNAP was always complete in 25 mM HCO3(-)-buffered solutions. In 5 mM HCO3- and in HCO3(-)-free solutions, however, nerves incubated in 25 mM glucose did not recover functionally after anoxia, whereas nerves bathed in solutions 2 or 3 showed a complete restitution of CNAP. We conclude that high glucose availability and low PO2 in the combination with decreased buffering power and/or inhibition of HCO3(-)-dependent pH regulation mechanisms may damage peripheral mammalian nerves due to a pronounced intracellular acidosis

    Effectiveness of interventions using self-monitoring to reduce sedentary behavior in adults : a systematic review and meta-analysis

    Get PDF
    Background: Sedentary behavior occurs largely subconsciously, and thus specific behavior change techniques are needed to increase conscious awareness of sedentary behavior. Chief amongst these behavior change techniques is self-monitoring of sedentary behavior. The aim of this systematic review and meta-analysis was to evaluate the short-term effectiveness of existing interventions using self-monitoring to reduce sedentary behavior in adults. Methods: Four electronic databases (PubMed, Embase, Web of Science, and The Cochrane Library) and grey literature (Google Scholar and the International Clinical Trials Registry Platform) were searched to identify appropriate intervention studies. Only (cluster-)randomized controlled trials that 1) assessed the short-term effectiveness of an intervention aimed at the reduction of sedentary behavior, 2) used self-monitoring as a behavior change technique, and 3) were conducted in a sample of adults with an average age >= 18 years, were eligible for inclusion. Relevant data were extracted, and Hedge's g was used as the measure of effect sizes. Random effects models were performed to conduct the meta-analysis. Results: Nineteen intervention studies with a total of 2800 participants met the inclusion criteria. Results of the meta-analyses showed that interventions using self-monitoring significantly reduced total sedentary time (Hedges g = 0,32; 95% CI = 0,14 - 0,50; p = 0,001) and occupational sedentary time (Hedge's g = 0,56; 95% CI = 0,07 - 0,90; p = 0,02) on the short term. Subgroup analyses showed that significant intervention effects were only found if objective self-monitoring tools were used (g = 0,40; 95% CI = 0,19 - 0,60; p < 0,001), and if the intervention only targeted sedentary behavior (g = 0,45; 95% CI = 0,15-0,75; p = 0,004). No significant intervention effects were found on the number of breaks in sedentary behavior. Conclusions: Despite the small sample sizes, and the large heterogeneity, results of the current meta-analysis suggested that interventions using self-monitoring as a behavior change technique have the potential to reduce sedentary behavior in adults. If future - preferably large-scale studies - can prove that the reductions in sedentary behavior are attributable to self-monitoring and can confirm the sustainability of this behavior change, multi-level interventions including self-monitoring may impact public health by reducing sedentary behavior

    Quantum Logic with a Single Trapped Electron

    Get PDF
    We propose the use of a trapped electron to implement quantum logic operations. The fundamental controlled-NOT gate is shown to be feasible. The two quantum bits are stored in the internal and external (motional) degrees of freedom.Comment: 7 Pages, REVTeX, No Figures, To appear in Phys. Rev.

    Mr imaging of the knee at 3t – diagnostic performance and comparison with 1.5t

    Get PDF
    The range of available magnetic field strengths for clinical knee MRI has expanded over the last 20 years, from below 0.2T to 1.5T, and, recently, 7T. The major advantage of high field strength MRI is the improvement in the signal-to-noise ratio (SNR), which can be used to either increase image resolution or decrease scan time and the chance for motion artifacts
    corecore