5 research outputs found

    Assessment of endothelial function by brachial artery flow mediated dilatation in microvascular disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiac syndrome X is an important therapeutic and diagnostic challenge to physician. Study of Csx patients may help to understand the pathophysiology of coronary microcirculation and to gain an insight on the management of these group patients.</p> <p>Methods</p> <p>We measured the flow mediated dilation of the brachial artery both endothelium dependent and independent vasodilatation by high resolution ultrasound in 30 cardiac syndrome X patients and matched with 30 healthy control subjects.</p> <p>Results</p> <p>Significantly decreased flow mediated dilatation was observed in patients when compared to control (9.42 ± 7.20 vs 21.11 ± 9.16 p < 0.01) but no significant difference was observed between groups in response to nitroglycerin (25.39 ± 6.82 vs 28.87 ± 8.69). Receiver operator characteristic analysis showed that value of < 11.11 had sensitivity of 80%, specificity 86.67%, positive predictive value 76.66%, negative predictive value 83.33%. In total, 46% of subjects had endothelial dysfunction and of them, CSX subjects had higher prevalence (76% vs 16% p < 0.01) than control subjects. Higher mean values of body mass index, systolic blood pressure and diastolic blood pressure was observed in subjects with FMD < 11.11 than > 11.11(p < 0.01). In logistic regression analysis, FMD was significantly associated with systolic blood pressure (Odds ratio 1.122 95% CI 1.053-1.196 p < 0.01) and body mass index (Odds 1.248 95%CI 0.995-1.56 p < 0.05).</p> <p>Conclusions</p> <p>The study suggests impairment of endothelial function in cardiac syndrome X patients. Increased Systolic blood pressure and body mass index may increase the risk of impairment of endothelial function in this group of patients.</p

    Real Time 3D Echocardiographic Evaluation of Iatrogenic Atrial Septal Defects After Percutaneous Transvenous Mitral Commissurotomy

    No full text
    Introduction: Percutaneous transvenous mitral commissurotomy (PTMC) is a safe and effective procedure for relief of severe mitral stenosis. PTMC is being done widely and many transseptal procedures requiring large diameter catheters, sheaths are becoming popular. The knowledge of iatrogenic atrial septal defect (iASD) is vital. This study assessed the use of real-time 3D echocardiography (RT3DE) and incidence of iASD in a cohort of patients undergoing transseptal catheterization during PTMC. Methods: One hundred ten patients underwent PTMC. The reliability and accuracy of RT3DE for iASD detection was determined, RT3DE was compared with 2D echocardiography (2DE) for iASD occurrence, influencing variables analyzed and followed up for 1 year. Results: RT3DE is more reliable and accurate for the study of iASD than 2DE. Color RT3DE detected iASD in 94 (85.5%), with 2DE iASD was detected in 74 (67.3%) (P<.0001). On follow up 85% had iASD post procedure, 56% at 6 months, 19% at 1 year follow up. The mean iASD diameter was 5.41 ± 3.12 mm and area 6.57 ± 3.81 mm2. iASD correlated with patient height, Wilkins score, pre-PTMC LA ‘v’, and post-PTMC LVEDP. Conclusion: RT3DE imaging is superior in accuracy to traditional 2DE techniques. All the modes of RT3DE are useful in the assessment of iASD. iASD measured by RT3DE correlates with several patient, procedural and echocardiographic variables
    corecore