17 research outputs found

    Refined heart failure detection algorithm for improved clinical reliability of OptiVol alerts in CRT-D recipients

    Get PDF
       Background: The reliability of intrathoracic impedance monitoring for prediction of heart failure (HF) by implantable cardiac devices is controversial. Despite using additional device-based parameters described in the PARTNERS HF study, such as new onset of arrhythmias, abnormal autonomics, low biventricular pacing rate or patient activity level, the predictive power of device diagnostic algorithm is still in doubt. The objective of this study was to compare the device diagnostic algorithm described in the PARTNERS HF study to a newly developed algorithm applying refined diagnostic criteria. Methods: Fourty two patients were prospectively enrolled who had been implanted with an intrathoracic impedance and remote monitoring capable implantable cardiac defibrillator with a cardiac resychroniza­tion therapy (CRT-D) device in this observational study. If a remote OptiVolTM alert occurred, patients were checked for presence of HF symptoms. A new algorithm was derived from the original PARTNERS HF criteria, considering more sensitive cut-offs and changes of patterns of the device-based parameters. Results: During an average follow-up of 38 months, 722 remote transmissions were received. From the total of 128 transmissions with OptiVol alerts, 32 (25%) corresponded to true HF events. Upon multivariate discriminant analysis, low patient activity, high nocturnal heart rate, and low CRT pacing (< 90%) proved to be independent predictors of true HF events (all p < 0.01). Incorporating these three refined criteria in a new algorithm, the diagnostic yield of OptiVol was improved by increasing specific­ity from 37.5% to 86.5%, positive predictive value from 34.1% to 69.8% and area under the curve from 0.787 to 0.922 (p < 0.01), without a relevant loss in sensitivity (96.9% vs. 93.8%). Conclusions: A refined device diagnostic algorithm based on the parameters of low activity level, high nocturnal heart rate, and suboptimal biventricular pacing might improve the clinical reliability of OptiVol alerts.  

    CRT Survey II: a European Society of Cardiology survey of cardiac resynchronisation therapy in 11 088 patients—who is doing what to whom and how?

    Get PDF
    Background: Cardiac resynchronisation therapy (CRT) reduces morbidity and mortality in appropriately selected patients with heart failure and is strongly recommended for such patients by guidelines. A European Society of Cardiology (ESC) CRT survey conducted in 2008–2009 showed considerable variation in guideline adherence and large individual, national and regional differences in patient selection, implantation practice and follow-up. Accordingly, two ESC associations, the European Heart Rhythm Association and the Heart Failure Association, designed a second prospective survey to describe contemporary clinical practice regarding CRT. Methods and results: A survey of the clinical practice of CRT-P and CRT-D implantation was conducted from October 2015 to December 2016 in 42 ESC member countries. Implanting centres provided information about their hospital and CRT service and were asked to complete a web-based case report form collecting information on patient characteristics, investigations, implantation procedures and complications during the index hospitalisation. The 11 088 patients enrolled represented 11% of the total number of expected implantations in participating countries during the survey period; 32% of patients were aged ≥75 years, 28% of procedures were upgrades from a permanent pacemaker or implantable cardioverter-defibrillator and 30% were CRT-P rather than CRT-D. Most patients (88%) had a QRS duration ≥130 ms, 73% had left bundle branch block and 26% were in atrial fibrillation at the time of implantation. Large geographical variations in clinical practice were observed. Conclusion: CRT Survey II provides a valuable source of information on contemporary clinical practice with respect to CRT implantation in a large sample of ESC member states. The survey permits assessment of guideline adherence and demonstrates variations in patient selection, management, implantation procedure and follow-up strategy

    De novo implantation vs. upgrade cardiac resynchronization therapy: a systematic review and meta-analysis

    Get PDF
    Patients with conventional pacemakers or implanted defibrillators are often considered for cardiac resynchronization therapy (CRT). Our aim was to summarize the available evidences regarding the clinical benefits of upgrade procedures. A systematic literature search was performed from studies published between 2006 and 2017 in order to compare the outcome of CRT upgrade vs. de novo implantations. Outcome data on all-cause mortality, heart failure events, New York Heart Association (NYHA) Class, QRS narrowing and echocardiographic parameters were analysed. A total of 16 reports were analysed comprising 489,568 CRT recipients, of whom 468,205 patients underwent de novo and 21,363 upgrade procedures. All-cause mortality was similar after CRT upgrade compared to de novo implantations (RR 1.19, 95% CI 0.88-1.60, p = 0.27). The risk of heart failure was also similar in both groups (RR 0.96, 95% CI 0.70-1.32, p = 0.81). There was no significant difference in clinical response after CRT upgrade compared to de novo implantations in terms of improvement in left ventricular ejection fraction (DeltaEF de novo - 6.85% vs. upgrade - 9.35%; p = 0.235), NYHA class (DeltaNYHA de novo - 0.74 vs. upgrade - 0.70; p = 0.737) and QRS narrowing (DeltaQRS de novo - 9.6 ms vs. upgrade - 29.5 ms; p = 0.485). Our systematic review and meta-analysis of currently available studies reports that CRT upgrade is associated with similar risk for all-cause mortality compared to de novo resynchronization therapy. Benefits on reverse remodelling and functional capacity improved similarly in both groups suggesting that CRT upgrade may be safely and effectively offered in routine practice. CLINICAL TRIAL REGISTRATION: Prospero Database-CRD42016043747

    Association of remote monitoring with survival in heart failure patients undergoing cardiac resynchronization therapy: Retrospective observational study

    No full text
    Background: Remote monitoring is an established, guideline-recommended technology with unequivocal clinical benefits; however, its ability to improve survival is contradictory. Objective: The aim of our study was to investigate the effects of remote monitoring on mortality in an optimally treated heart failure patient population undergoing cardiac resynchronization defibrillator therapy (CRT-D) implantation in a large-volume tertiary referral center. Methods: The population of this single-center, retrospective, observational study included 231 consecutive patients receiving CRT-D devices in the Medical Centre of the Hungarian Defence Forces (Budapest, Hungary) from January 2011 to June 2016. Clinical outcomes were compared between patients on remote monitoring and conventional follow-up. Results: The mean follow-up time was 28.4 (SD 18.1) months. Patients on remote monitoring were more likely to have atrial fibrillation, received heart failure management at our dedicated heart failure outpatient clinic more often, and have a slightly lower functional capacity. Crude all-cause mortality of remote-monitored patients was significantly lower compared with patients followed conventionally (hazard ratio [HR] 0.368, 95% CI 0.186-0.727, P=.004). The survival benefit remained statistically significant after adjustment for important baseline parameters (adjusted HR 0.361, 95% CI 0.181-0.722, P=.004). Conclusions: In this single-center, retrospective study of optimally treated heart failure patients undergoing CRT-D implantation, the use of remote monitoring systems was associated with a significantly better survival rate

    Implantation of the Micra transcatheter pacing system: Single Polish center experience with the real costs of hospitalization analysis

    Get PDF
    Background: The Micra transcatheter pacing system (TPS) is a miniaturized, single-chamber pacemaker system. Study reported herein is an initial experience with implantation of the Micra TPS. Methods: The leadless pacemaker was implanted in 10 patients with standard indications for a permanent pacemaker implantation. All hospitalization costs were calculated for all patients. Results: The mean age of the patients was 75 ± 7.1 years, 6 were men and 4 were women. Four patients had permanent atrial fibrillation as the basal rhythm and 6 patients had sinus rhythm. All patients had at least one relative contraindication that precluded the use of a traditional pacing system. Mean intraoperative ventricular sensing amplitude was 10.6 ± 5.4 mV, impedance 843 ± 185 ohms, and pacing threshold at 0.24 ms was 0.56 ± 0.23 V. At discharge, those values were 13.9 ± 5.6 mV, 667 ± 119 ohms and 0.47 ± 0.17, respectively. The mean duration of implantation procedure was 82 min, while mean fluoroscopy time was 3.5 min. Two patients developed hematoma at the groin puncture site post-implantation. In 1 case there was a need for erythrocyte mass transfusion and surgical intervention. Mean total time of hospitalization was 26 days and time from procedure to discharge 12 days. Average cost of hospitalization per 1 patient was 11,260.15 EUR minimal cost was 9,052.68 EUR, while maximal cost was 16,533.18 EUR. Conclusions: Implantation of leadless pacemakers is feasible, safe and provides advantages over the conventional system. Hospitalization costs vary for individual patients in wide range

    Risk of cardiac arrhythmias after electrical accident: a single-center study of 480 patients

    No full text
    Objective: Patients with electrical injury are considered to be at high risk of cardiac arrhythmias. Due to the small number of studies, there is no widely accepted guideline regarding the risk assessment and management of arrhythmic complications after electrical accident (EA). Our retrospective observational study was designed to determine the prevalence of ECG abnormalities and cardiac arrhythmias after EA, to evaluate the predictive value of cardiac biomarkers for this condition and to assess in-hospital and 30-day mortality. Methods: Consecutive patients presenting after EA at the emergency department of our institution between 2011 and 2016 were involved in the current analysis. ECG abnormalities and arrhythmias were analyzed at admission and during ECG monitoring. Levels of cardiac troponin I, CK and CK-MB were also collected. In-hospital and 30-day mortality data were obtained from hospital records and from the national insurance database. Results: Of the 480 patients included, 184 (38.3%) had suffered a workplace accident. The majority of patients (96.2%) had incurred a low-voltage injury ( 100 bpm, n = 21, 4.4%). Other detected arrhythmias were as follows: newly diagnosed atrial fibrillation (n = 1); frequent multifocal atrial premature complexes (n = 1); sinus arrest with atrial escape rhythm (n = 2); ventricular fibrillation terminated out of hospital (n = 1); ventricular bigeminy (n = 1); and repetitive nonsustained ventricular tachycardia (n = 1). ECG monitoring was performed in 182 (37.9%) patients for 12.7 ± 7.1 h at the ED. Except for one case with regular supraventricular tachycardia terminated via vagal maneuver and one other case with paroxysmal atrial fibrillation, no clinically relevant arrhythmias were detected during the ECG monitoring. Cardiac troponin I was measured in 354 (73.8%) cases at 4.6 ± 4.3 h after the EA and was significantly elevated only in one resuscitated patient. CK elevation was frequent, but CK-MB was under 5% in all patients. Both in-hospital and 30-day mortality were 0%. Conclusions: Most of cardiac arrhythmias in patients presenting after EA can be diagnosed by an ECG on admission, thus routine ECG monitoring appears to be unnecessary. In our patient cohort cardiac troponin I and CK-MB were not useful in risk assessment after EA. Late-onset malignant arrhythmias were not observed
    corecore