468 research outputs found
Economic Change and Fiscal Planning: The Origins of the Fiscal Crisis in New York State
What can policy makers learn from the fiscal experience of New York during the 1980s? By most measures, the state went from a position of fiscal strength in the early 1980s to fiscal crisis by the end of the decade. In their analysis of demographic, social, economic, and fiscal patterns, Roy Bahl and William Duncombe show that the lack of long-term fiscal planning and short-term discipline were the root causes of the turnabout. They call for greater use of both, as well as tax reforms that will better reflect the changing reality of local and state economies
Interferometric Astrometry of Proxima Centauri and Barnard's Star Using Hubble Space Telescope Fine Guidance Sensor 3: Detection Limits for sub-Stellar Companions
We report on a sub-stellar companion search utilizing interferometric
fringe-tracking astrometry acquired with Fine Guidance Sensor 3 (FGS 3) on the
Hubble Space Telescope. Our targets were Proxima Centauri and Barnard's Star.
We obtain absolute parallax values for Proxima Cen pi_{abs} = 0.7687 arcsecond
and for Barnard's Star pi_{abs} = 0.5454 arcsecond.
Once low-amplitude instrumental systematic errors are identified and removed,
our companion detection sensitivity is less than or equal to one Jupiter mass
for periods longer than 60 days for Proxima Cen. Between the astrometry and the
radial velocity results we exclude all companions with M > 0.8M_{Jup} for the
range of periods 1 < P < 1000 days. For Barnard's Star our companion detection
sensitivity is less than or equal to one Jupiter mass for periods long er than
150 days. Our null results for Barnard's Star are consistent with those of
Gatewood (1995).Comment: 35 pages, 13 figures, to appear in August 1999 A
Photometry of Proxima Centauri and Barnard's Star Using HST Fine Guidance Sensor 3: A Search for Periodic Variations
We have observed Proxima Centauri and Barnard's Star with Hubble Space
Telescope Fine Guidance Sensor 3. Proxima Centauri exhibits small-amplitude,
periodic photometric variations. Once several sources of systematic photometric
error are corrected, we obtain 2 milli-magnitude internal photometric
precision. We identify two distinct behavior modes over the past four years:
higher amplitude, longer period; smaller amplitude, shorter period. Within the
errors one period (P ~ 83d) is twice the other. Barnard's Star shows very weak
evidence for periodicity on a timescale of approximately 130 days. If we
interpret these periodic phenomena as rotational modulation of star spots, we
identify three discrete spots on Proxima Cen and possibly one spot on Barnard's
Star. We find that the disturbances change significantly on time scales as
short as one rotation period.Comment: 39 pages, 17 figure
Recommended from our members
The Distance To The Hyades Cluster Based On Hubble Space Telescope Fine Guidance Sensor Parallaxes
Trigonometric parallax observations made with the Hubble Space Telescope (HST) Fine Guidance Sensor (FGS) 3 of seven Hyades members in six fields of view have been analyzed along with their proper motions to determine the distance to the cluster. Knowledge of the convergent point and mean proper motion of the Hyades is critical to the derivation of the distance to the center of the cluster. Depending on the choice of the proper-motion system, the derived cluster center distance varies by 9%. Adopting a reference distance of 46.1 pc or m - M = 3.32, which is derived from the ground-based parallaxes in the General Catalogue of Trigonometric Stellar Parallaxes (1995 edition), the FK5/PPM proper-motion system yields a distance 4% larger, while the Hanson system yields a distance 2% smaller. The HST FGS parallaxes reported here yield either a 14% or 5% larger distance, depending on the choice of the proper-motion system. Orbital parallaxes (Torres et al.) yield an average distance 4% larger than the reference distance. The variation in the distance derived from the HST data illustrates the importance of the proper-motion system and the individual proper motions to the derivation of the distance to the Hyades center; therefore, a full utilization of the HST FGS parallaxes awaits the establishment of an accurate and consistent proper-motion system.NASA HST GTO, HF-1042.01-93A, HF-1046.01-93A, NAS526555Astronom
Monochorionic triamniotic triplet pregnancy with a co-triplet fetus discordant for congenital cystic adenomatoid malformation of the lung
BACKGROUND: Spontaneous monochorionic triamniotic pregnancy is rare and is at increased risk for pregnancy complications. The presence of an anomalous fetus further complicates the management. CASE PRESENTATION: We present a case of monochorionic triamniotic triplet pregnancy diagnosed at 15 weeks of gestation with one fetus having developed a multicystic lung lesion, suggestive of congenital cystic adenomatoid malformation (CCAM). At 24 weeks, the largest cyst measured 10 mm in diameter. We managed the pregnancy conservatively and delivered three live male fetuses with birth weights 1560 g, 1580 g and 1590 g at 35 weeks of gestation. Two newborns were admitted to the neonatal intensive care unit with respiratory distress, the third one died due to sepsis 7 days postpartum. One of the newborns was discharged healthy at 24 days postpartum. The newborn with CCAM developed a pneumothorax on the right side, recovered after treatment, and was discharged after one month. Computerized tomography (CT) of the infant at 3 months demonstrated two cystic lesions in the middle lobe of the right lung measuring 25 mm and 15 mm. A repeat CT of the infant at 6 months showed a 30 mm solitary cystic mass. CONCLUSION: Monochorionic triamniotic triplet pregnancy with a co-triplet fetus discordant for CCAM, present rarely and can be managed conservatively. These findings may help in decision making and counselling of parents
Astrometry with Hubble Space Telescope: A Parallax of the Fundamental Distance Calibrator RR Lyrae
We present an absolute parallax and relative proper motion for the
fundamental distance scale calibrator, RR Lyr. We obtain these with astrometric
data from FGS 3, a white-light interferometer on HST. We find mas. Spectral classifications and VRIJHKTM and DDO51 photometry of
the astrometric reference frame surrounding RR Lyr indicate that field
extinction is low along this line of sight. We estimate =0.07\pm0.03 for
these reference stars. The extinction suffered by RR Lyr becomes one of the
dominant contributors to the uncertainty in its absolute magnitude. Adopting
the average field absorption, =0.07 \pm 0.03, we obtain M_V^{RR} = 0.61
^{-0.11}_{+0.10}. This provides a distance modulus for the LMC, m-M = 18.38 -
18.53^{-0.11}_{+0.10} with the average extinction-corrected magnitude of RR Lyr
variables in the LMC, , remaining a significant uncertainty. We compare
this result to more than 80 other determinations of the distance modulus of the
LMC.Comment: Several typos corrected. To appear in The Astronomical Journal,
January 200
- …