268 research outputs found

    Proline provides site-specific flexibility for in vivo collagen.

    Get PDF
    Fibrillar collagens have mechanical and biological roles, providing tissues with both tensile strength and cell binding sites which allow molecular interactions with cell-surface receptors such as integrins. A key question is: how do collagens allow tissue flexibility whilst maintaining well-defined ligand binding sites? Here we show that proline residues in collagen glycine-proline-hydroxyproline (Gly-Pro-Hyp) triplets provide local conformational flexibility, which in turn confers well-defined, low energy molecular compression-extension and bending, by employing two-dimensional 13C-13C correlation NMR spectroscopy on 13C-labelled intact ex vivo bone and in vitro osteoblast extracellular matrix. We also find that the positions of Gly-Pro-Hyp triplets are highly conserved between animal species, and are spatially clustered in the currently-accepted model of molecular ordering in collagen type I fibrils. We propose that the Gly-Pro-Hyp triplets in fibrillar collagens provide fibril "expansion joints" to maintain molecular ordering within the fibril, thereby preserving the structural integrity of ligand binding sites.BBSRC, EPSRC, Raymond and Beverly Sackler Fund for Physics of Medicine, Wellcome Trust, ER

    Direct Observation of Proton-Neutron Short-Range Correlation Dominance in Heavy Nuclei

    Get PDF
    We measured the triple coincidence A(e,e′n p) and A(e,e′ p p) reactions on carbon, aluminum, iron, and lead targets at Q2 \u3e1.5  (GeV/c)2, xB \u3e 1.1 and missing momentum \u3e400  MeV/c. This was the first direct measurement of both proton-proton (pp) and neutron-proton (np) short-range correlated (SRC) pair knockout from heavy asymmetric nuclei. For all measured nuclei, the average proton-proton (pp) to neutron-proton (np) reduced cross-section ratio is about 6%, in agreement with previous indirect measurements. Correcting for single-charge exchange effects decreased the SRC pairs ratio to ∼3%, which is lower than previous results. Comparisons to theoretical generalized contact formalism (GCF) cross-section calculations show good agreement using both phenomenological and chiral nucleon-nucleon potentials, favoring a lower pp to np pair ratio. The ability of the GCF calculation to describe the experimental data using either phenomenological or chiral potentials suggests possible reduction of scale and scheme dependence in cross-section ratios. Our results also support the high-resolution description of high-momentum states being predominantly due to nucleons in SRC pairs

    Scheme for the generation of an entangled four-photon W-state

    Full text link
    We present a scheme to produce an entangled four-photon W-state by using linear optical elements. The symmetrical setup of linear optical elements consists of four beam splitters, four polarization beam splitters and four mirrors. A photon EPR-pair and two single photons are required as the input modes. The projection on the W-state can be made by a four-photon coincidence measurement. Further, we show that by means of a horizontally oriented polarizer in front of one detector the W-state of three photons can be generated.Comment: titile is changed, to appear in PR

    The CLAS12 Backward Angle Neutron Detector (BAND)

    Full text link
    The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155∘155^\circ to 175∘175^\circ, with momenta between 200200 and 600600 MeV/c. It is positioned 3 meters upstream of the target, consists of 1818 rows and 55 layers of 7.27.2 cm by 7.27.2 cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2 cm thick lead wall followed by a 2 cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250250 ps (150 ps) for energy depositions above 2 MeVee (5 MeVee). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. The time resolution results in a neutron momentum reconstruction resolution, δp/p<1.5\delta p/p < 1.5\% for neutron momentum 200≤p≤600200\le p\le 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron-neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.Comment: 17 pages, 25 figures, 3 tables. Accepted for publication in NIM-
    • …
    corecore