40 research outputs found

    Repair of calvarial bone defects in mice using electrospun polystyrene scaffolds combined with β-TCP or gold nanoparticles

    Get PDF
    Non-biodegradable porous polystyrene (PS) scaffolds, composed of microfibers, have been prepared by electrospinning for the reconstruction of large bone defects. PS microfibers were prepared by incorporating β-TCP grains inside the polymer or grafting gold nanoparticles surface functionalized with mercaptosuccinic acid. Cytocompatibility of the three types of scaffolds (PS, β-TCP-PS and Au-PS) was studied by seeding human mesenchymal stem cells. Biocompatibility was evaluated by implanting β-TCP-PS and Au-PS scaffolds into a critical size (4mm) calvarial defect in mice. Calvaria were taken 6, 9, and 12 weeks after implantation; newly formed bone and cellular response was analyzed by microcomputed tomography (microCT) and histology. β-TCP-PS scaffolds showed a significantly higher cell proliferation in vitro than on PS or Au-PS alone; clearly, the presence of β-TCP grains improved cytocompatibility. Biocompatibility study in the mouse calvaria model showed that β-TCP-PS scaffolds were significantly associated with more newly-formed bone than Au-PS. Bone developed by osteoconduction from the defect margins to the center. A dense fibrous connective tissue containing blood vessels was identified histologically in both types of scaffolds. There was no inflammatory foci nor giant cell in these areas. AuNPs aggregates were identified histologically in the fibrosis and also incorporated in the newly-formed bone matrix. Although the different types of PS microfibers appeared cytocompatible during the in vitro experiment, they appeared biotolerated in vivo since they induced a fibrotic reaction associated with newly formed bone

    Nanocomposite particles with improved microstructure for 3D culture systems and bone regeneration

    Get PDF
    Nano-apatite and gelatin-alginate hydrogel microparticles have been prepared by a one-step synthesis combined with electrostatic bead generation, for the reconstruction of bone defects. Based on the analysis of bone composition, architecture and embryonic intramembranous ossification, a bio-inspired fabrication has been developed. Accordingly, the mineral phase has been in situ synthesized, calcifying the hydrogel matrix while the latter was crosslinked, finally generating microparticles that can assemble into a bone defect to ensure interconnected pores. Although nano-apatite-biopolymer composites have been widely investigated, microstructural optimization to provide improved distribution and stability of the mineral is rarely achieved. The optimization of the developed method progressively resulted in two types of formulations (15P and 7.5P), with 15 and 7.5 (wt%) phosphate content in the initial precursor. The osteolytic potential was investigated using differentiated macrophages. A commercially available calcium phosphate bone graft substitute (Eurocer 400) was incorporated into the hydrogel, and the obtained composites were in vitro tested for comparison. The cytocompatibility of the microparticles was studied with mouse osteoblast-like cell line MC3T3-E1. Results indicated the best in vitro performance have been obtained for the sample loaded with 7.5P. Preliminary evaluation of biocompatibility into a critical size (3 mm) defect in rabbits showed that 7.5P nanocomposite is associated with newly formed bone in the proximity of the microparticles, after 28 days

    Evaluating model outputs using integrated global speleothem records of climate change since the last glacial

    Get PDF
    Although quantitative isotope data from speleothems has been used to evaluate isotope-enabled model simulations, currently no consensus exists regarding the most appropriate methodology through which to achieve this. A number of modelling groups will be running isotope-enabled palaeoclimate simulations in the framework of the Coupled Model Intercomparison Project Phase 6, so it is timely to evaluate different approaches to using the speleothem data for data–model comparisons. Here, we illustrate this using 456 globally distributed speleothem δ18O records from an updated version of the Speleothem Isotopes Synthesis and Analysis (SISAL) database and palaeoclimate simulations generated using the ECHAM5-wiso isotope-enabled atmospheric circulation model. We show that the SISAL records reproduce the first-order spatial patterns of isotopic variability in the modern day, strongly supporting the application of this dataset for evaluating model-derived isotope variability into the past. However, the discontinuous nature of many speleothem records complicates the process of procuring large numbers of records if data–model comparisons are made using the traditional approach of comparing anomalies between a control period and a given palaeoclimate experiment. To circumvent this issue, we illustrate techniques through which the absolute isotope values during any time period could be used for model evaluation. Specifically, we show that speleothem isotope records allow an assessment of a model's ability to simulate spatial isotopic trends. Our analyses provide a protocol for using speleothem isotope data for model evaluation, including screening the observations to take into account the impact of speleothem mineralogy on δ18O values, the optimum period for the modern observational baseline and the selection of an appropriate time window for creating means of the isotope data for palaeo-time-slices

    Moving from contractor to owner operator: Impact on safety culture; a case study

    Get PDF
    Purpose – The purpose of this paper is to investigate whether a change in staffing contractual arrangements, specific training in hazard identification, mentoring of supervisors and the introduction of a robust safety system could improve an organisation\u27s safety culture. How safety conditions change under contracted out labour compared to direct labour and the influence that contracting out has on organisational safety culture is explored. Design/methodology/approach – The study used a case study methodology to detail how the change occurred over a six month period in 2011. As part of the analysis a model of the change process and push-pull factors is offered. Findings – As a result of the change, all areas saw some improvement. Work-related injury statistics dropped significantly, supervisors were clear of their roles, actively monitoring their crews to ensure they worked in a safer manner than before, and staff were actively addressing work-place hazards. With the safety system in place the organisation should be deemed compliant and diligent by the state auditing authorities. This study has also shown that using contractor workers together with in-house workers that are managed under different safety regimes is problematic. The problems don’t occur due to the contractor\u27s safety systems being less robust than the parent company\u27s or that contract workers are themselves less safe; it is the added complexity of managing multiple safety regimes and the lack of trust of the robustness of each system that create conflict. Research limitations/implications – The paper reports on the change process of one mining organisation in Western Australia as a case study from a managerial sample and is thereby limited. Practical implications – This study demonstrates the difficulties in changing safety culture in an underground mining organisation. The paper argues the need for specialised training in identifying hazards by the staff, the mentoring of supervisory staff and the adoption of a robust safety system to support improved safety culture. Originality/value – There is little research conducted in the resources sector researching changes in human resource supply and OHS management, in particular moving from contracted labour to hiring in-house. This case provides an insight into how a change in staffing hiring arrangements, together with specific safety initiatives, has a positive impact on safety performance

    2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary.

    Get PDF
    S

    2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary.

    Get PDF
    S

    withdrawn 2017 hrs ehra ecas aphrs solaece expert consensus statement on catheter and surgical ablation of atrial fibrillation

    Get PDF
    n/
    corecore