11 research outputs found

    Early detection of left ventricular diastolic dysfunction using conventional and speckle tracking echocardiography in a large animal model of metabolic dysfunction

    Get PDF
    Left ventricular (LV) diastolic dysfunction is one of the important mechanisms responsible for symptoms in patients with heart failure. The aim of the current study was to identify parameters that may be used to detect early signs of LV diastolic dysfunction in diabetic pigs on a high fat diet, using conventional and speckle tracking echocardiography. The study population consisted of 16 healthy Göttingen minipigs and 18 minipigs with experimentally induced metabolic dysfunction. Echocardiography measurements wer

    Sequential Alcohol Septal Ablation to Resolve LV Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement

    Get PDF
    Left ventricular outflow tract obstruction (LVOTO) is a notorious complication of transcatheter mitral valve replacement (TMVR). Computed tomography–derived simulations can predict neo-LVOTO post-TMVR, whereas alcohol septal ablation can mitigate neo-LVOTO risk. We report a case of sequential alcohol septal ablation of 2 adjacent septal branches to resolve unexpected neo-LVOTO post-TMVR.</p

    Sequential Alcohol Septal Ablation to Resolve LV Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement

    Get PDF
    Left ventricular outflow tract obstruction (LVOTO) is a notorious complication of transcatheter mitral valve replacement (TMVR). Computed tomography–derived simulations can predict neo-LVOTO post-TMVR, whereas alcohol septal ablation can mitigate neo-LVOTO risk. We report a case of sequential alcohol septal ablation of 2 adjacent septal branches to resolve unexpected neo-LVOTO post-TMVR.</p

    Early detection of left ventricular diastolic dysfunction using conventional and speckle tracking echocardiography in a large animal model of metabolic dysfunction

    Get PDF
    Left ventricular (LV) diastolic dysfunction is one of the important mechanisms responsible for symptoms in patients with heart failure. The aim of the current study was to identify parameters that may be used to detect early signs of LV diastolic dysfunction in diabetic pigs on a high fat diet, using conventional and speckle tracking echocardiography. The study population consisted of 16 healthy Göttingen minipigs and 18 minipigs with experimentally induced metabolic dysfunction. Echocardiography measurements were performed at baseline and 3-month follow-up. The ratio of peak early (E) and late filling velocity (E/A ratio) and the ratio of E and the velocity of the mitral annulus early diastolic wave (E/Em ratio) did not change significantly in both groups. Peak untwisting velocity decreased in the metabolic dysfunction group (− 30.1 ± 18.5 vs. − 23.4 ± 15.5 °/ms) but not in controls (− 38.1 ± 23.6 vs. − 42.2 ± 23.0 °/ms), being significantly different between the groups at the 3-month time point (p < 0.05). In conclusion, whereas E/A ratio and E/Em ratio did not change significantly after 3 months of metabolic dysfunction, peak untwisting velocity was significantly decreased. Hence, peak untwisting velocity may serve as an important marker to detect early changes of LV diastolic dysfunction.</p

    Comparative analysis of different risk prediction tools after mitral Transcatheter edge-to-edge repair

    Get PDF
    Background: Transcatheter edge-to-edge repair (TEER) has become an established treatment for primary and secondary mitral regurgitation (PMR and SMR). The objective of this study was to compare the accuracy of different risk scores for predicting 1-year mortality and the composite endpoint of 1-year mortality and/or heart failure (HF) hospitalization after TEER. Methods: We analyzed data from 206 patients treated for MR at a tertiary European center between 2011 and 2023 and compared the accuracy of different mitral and surgical risk scores: EuroSCORE II, GRASP, MITRALITY, MitraScore, TAPSE/PASP-MitraScore, and STS for predicting 1-year mortality and the composite of 1-year mortality and/or HF hospitalization in PMR and SMR. A subanalysis of SMR-only patients with the addition of COAPT Risk Score and baseline N-Terminal pro-Brain Natriuretic Peptide (NT-proBNP) list was also performed. Results: MITRALITY had the best discriminative ability for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with an area under the curve (AUC) of 0.74 and 0.74, respectively, in a composed group of PMR and SMR. In a SMR-only population, MITRALITY also presented the best AUC for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with values of 0.72 and 0.72, respectively. Conclusion: MITRALITY was the best mitral TEER risk model for both 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization in a population of PMR and SMR patients, as well as in SMR patients only. Surgical risk scores, MitraScore, TAPSE/PASP-MitraScore and NT-proBNP alone showed poor predictive values.</p

    Redo Transcatheter Aortic Valve Implantation in the Lotus Mechanically Expanded Transcatheter Heart Valve:Bench-Top Analysis, Clinical Experience, and Procedural Guidance

    No full text
    BACKGROUND: Redo transcatheter aortic valve implantation (TAVI) is increasing as patients outlive their transcatheter heart valves (THVs) and present with bioprosthetic valve failure. The Lotus mechanically expanded THV has unique design characteristics, which have specific implications for Redo TAVI. METHODS: The design features of the Lotus valve and their relevance to Redo TAVI were reviewed. Bench-top analysis of Redo TAVI was performed using different contemporary THVs. Procedural and outcome data were obtained from 10 patients who had undergone Redo TAVI for Lotus bioprosthetic valve failure in 5 centers. Recommendations for performing Redo TAVI in Lotus are made, based on these findings.RESULTS: The Lotus leaflets extend from the frame inflow, with a Neoskirt of only 13 mm, hence a low risk of coronary obstruction during Redo TAVI. The Lotus frame posts prevent full apposition of the Redo prosthesis in the upper part of the frame, while implantation of the Redo THV above the Lotus inflow leads to inadequate apposition of the Lotus leaflets. Inflow-to-inflow positioning is therefore recommended for effective sealing and leaflet pinning. The Lotus locking mechanism prevents overexpansion of the frame, limiting Redo THV oversizing. Redo TAVI was favorable with SAPIEN 3, Evolut, and Navitor THVs on bench-top analysis but not with ACURATE Neo 2 due to the upper crowns and short stent preventing inflow-to-inflow deployment. Case review demonstrated satisfactory outcomes in 10 patients treated with Evolut (n=6), SAPIEN 3 (n=3), and Portico (n=1) valves, with no mortality, major morbidity, or coronary obstruction. Three patients had residual mean gradient ≥20 mm Hg, including 2 of 3 SAPIEN cases. Guidance on procedural planning, valve choice, sizing, and positioning is provided. CONCLUSIONS: Redo TAVI in Lotus requires an understanding of unique design characteristics, and adherence to key procedural recommendations, but can be safely and effectively performed with most contemporary valve types.</p

    Redo Transcatheter Aortic Valve Implantation in the Lotus Mechanically Expanded Transcatheter Heart Valve:Bench-Top Analysis, Clinical Experience, and Procedural Guidance

    No full text
    BACKGROUND: Redo transcatheter aortic valve implantation (TAVI) is increasing as patients outlive their transcatheter heart valves (THVs) and present with bioprosthetic valve failure. The Lotus mechanically expanded THV has unique design characteristics, which have specific implications for Redo TAVI. METHODS: The design features of the Lotus valve and their relevance to Redo TAVI were reviewed. Bench-top analysis of Redo TAVI was performed using different contemporary THVs. Procedural and outcome data were obtained from 10 patients who had undergone Redo TAVI for Lotus bioprosthetic valve failure in 5 centers. Recommendations for performing Redo TAVI in Lotus are made, based on these findings.RESULTS: The Lotus leaflets extend from the frame inflow, with a Neoskirt of only 13 mm, hence a low risk of coronary obstruction during Redo TAVI. The Lotus frame posts prevent full apposition of the Redo prosthesis in the upper part of the frame, while implantation of the Redo THV above the Lotus inflow leads to inadequate apposition of the Lotus leaflets. Inflow-to-inflow positioning is therefore recommended for effective sealing and leaflet pinning. The Lotus locking mechanism prevents overexpansion of the frame, limiting Redo THV oversizing. Redo TAVI was favorable with SAPIEN 3, Evolut, and Navitor THVs on bench-top analysis but not with ACURATE Neo 2 due to the upper crowns and short stent preventing inflow-to-inflow deployment. Case review demonstrated satisfactory outcomes in 10 patients treated with Evolut (n=6), SAPIEN 3 (n=3), and Portico (n=1) valves, with no mortality, major morbidity, or coronary obstruction. Three patients had residual mean gradient ≥20 mm Hg, including 2 of 3 SAPIEN cases. Guidance on procedural planning, valve choice, sizing, and positioning is provided. CONCLUSIONS: Redo TAVI in Lotus requires an understanding of unique design characteristics, and adherence to key procedural recommendations, but can be safely and effectively performed with most contemporary valve types.</p
    corecore