    Real-time monitoring of exhaled volatiles using atmospheric pressure chemical ionization on a compact mass spectrometer

    Get PDF
    © 2016 Future Science Ltd.Aim: Breath analyses have potential to detect early signs of disease onset. Ambient ionization allows direct combination of breath gases with MS for fast, on-line analysis. Portable MS systems would facilitate field/clinic-based breath analyses. Results & methodology: Volunteers ingested peppermint oil capsules and exhaled volatile compounds were monitored over 10 h using a compact mass spectrometer. A rise and fall in exhaled menthone was observed, peaking at 60-120 min. Real-time analysis showed a gradual rise in exhaled menthone postingestion. Sensitivity was comparable to established methods, with detection in the parts per trillion range. Conclusion: Breath volatiles were readily analyzed on a portable mass spectrometer through a simple inlet modification. Induced changes in exhaled profiles were detectable with high sensitivity and measurable in real-time

    Assessment of breath volatile organic compounds in acute cardiorespiratory breathlessness: a protocol describing a prospective real-world observational study

    Get PDF
    Introduction Patients presenting with acute undifferentiated breathlessness are commonly encountered in admissions units across the UK. Existing blood biomarkers have clinical utility in distinguishing patients with single organ pathologies but have poor discriminatory power in multifactorial presentations. Evaluation of volatile organic compounds (VOCs) in exhaled breath offers the potential to develop biomarkers of disease states that underpin acute cardiorespiratory breathlessness, owing to their proximity to the cardiorespiratory system. To date, there has been no systematic evaluation of VOC in acute cardiorespiratory breathlessness. The proposed study will seek to use both offline and online VOC technologies to evaluate the predictive value of VOC in identifying common conditions that present with acute cardiorespiratory breathlessness. Methods and analysis A prospective real-world observational study carried out across three acute admissions units within Leicestershire. Participants with self-reported acute breathlessness, with a confirmed primary diagnosis of either acute heart failure, community-acquired pneumonia and acute exacerbation of asthma or chronic obstructive pulmonary disease will be recruited within 24 hours of admission. Additionally, school-age children admitted with severe asthma will be evaluated. All participants will undergo breath sampling on admission and on recovery following discharge. A range of online technologies including: proton transfer reaction mass spectrometry, gas chromatography ion mobility spectrometry, atmospheric pressure chemical ionisation-mass spectrometry and offline technologies including gas chromatography mass spectroscopy and comprehensive two-dimensional gas chromatography-mass spectrometry will be used for VOC discovery and replication. For offline technologies, a standardised CE-marked breath sampling device (ReCIVA) will be used. All recruited participants will be characterised using existing blood biomarkers including C reactive protein, brain-derived natriuretic peptide, troponin-I and blood eosinophil levels and further evaluated using a range of standardised questionnaires, lung function testing, sputum cell counts and other diagnostic tests pertinent to acute disease. Ethics and dissemination The National Research Ethics Service Committee East Midlands has approved the study protocol (REC number: 16/LO/1747). Integrated Research Approval System (IRAS) 198921. Findings will be presented at academic conferences and published in peer-reviewed scientific journals. Dissemination will be facilitated via a partnership with the East Midlands Academic Health Sciences Network and via interaction with all UK-funded Medical Research Council and Engineering and Physical Sciences Research Council molecular pathology nodes. Trial registration number NCT0367299

    Breath selection methods for compact mass spectrometry breath analysis

    No full text
    Compact mass spectrometry (CMS) is a versatile and transportable analytical instrument that has the potential to be used in clinical settings to quickly and non-invasively detect a wide range of relevant conditions from breath samples. The purpose of this study is to optimise data preprocessing protocols by three proposed methods of breath sampling, using the CMS. It also lays out a general framework for which data processing methods can be evaluated. METHODS: This paper considers data from three previous studies, each using a different breath sampling method. These include a peppermint washout study using continuous breath sampling with a purified air source, an exercise study using continuous breath sampling with an ambient air source, and a single breath sampling study with an ambient air source. For each dataset, different breath selection (data preprocessing) methods were compared and benchmarked according to predictive performance on a validation set and quantitative reliability of m/z bin intensity measurements. RESULTS: For both continuous methods, the best breath selection method improved the predictive model compared to no preselection, as measured by the 95% CI range for Youden's index, from 0.68-0.86 to 0.86-0.97 for the exercise study and 0.69-0.82 to 1.00-1.00 for the peppermint study. The reliability of intensity measurements for both datasets (as measured by median relative standard deviation (RSD)), was improved slightly by the best selection method compared to no preselection, from 18% to 14% for the exercise study and 7%-5% for the peppermint study. For the single breath samples, all the models resulted in perfect prediction, with a 95% CI range for Youden's index of 1.00-1.00. The reliability of the proposed method was 38%. CONCLUSION: The method of selecting exhaled breath from CMS data can affect the reliability of the measurement and the ability to distinguish between breath samples taken under different conditions. The application of appropriate data processing methods can improve the quality of the data and results obtained from CMS. The methods presented will enable untargeted analysis of breath VOCs using CMS to be performed

    Breath markers for therapeutic radiation

    No full text
    Radiation dose is important in radiotherapy. Too little, and the treatment is not effective, too much causes radiation toxicity. A biochemical measurement of the effect of radiotherapy would be useful in personalisation of this treatment. This study evaluated changes in exhaled breath volatile organic compounds (VOC) associated with radiotherapy with thermal desorption gas chromatography mass-spectrometry followed by data processing and multivariate statistical analysis. Further the feasibility of adopting gas chromatography ion mobility spectrometry for radiotherapy point-of-care breath was assessed. A total of 62 participants provided 240 end-tidal 1 dm3 breath samples before radiotherapy and at 1, 3, and 6 h post-exposure, that were analysed by thermal-desorption/gas-chromatography/quadrupole mass-spectrometry. Data were registered by retention-index and mass-spectra before multivariate statistical analyses identified candidate markers.A panel of sulfur containing compounds (thio-VOC) were observed to increase in concentration over the 6 h following irradiation. 3-methylthiophene (80 ng.m−3 to 790 ng.m−3) had the lowest abundance while 2-thiophenecarbaldehyde(380 ng.m−3 to 3.85 μg.m−3) the highest; note, exhaled 2-thiophenecarbaldehyde has not been observed previously. The putative tumour metabolite 2,4-dimethyl-1-heptene concentration reduced by an average of 73% over the same time. Statistical scoring based on the signal intensities thio-VOC and 3-methylthiophene appears to reflect individuals' responses to radiation exposure from radiotherapy. The thio-VOC are hypothesised to derive from glutathione and Maillard-based reactions and these are of interest as they are associated with radio-sensitivity. Further studies with continuous monitoring are needed to define the development of the breath biochemistry response to irradiation and to determine the optimum time to monitor breath for radiotherapy markers. Consequently, a single 0.5 cm3 breath-sample gas chromatography-ion mobility approach was evaluated. The calibrated limit of detection for 3-methylthiophene was 10 μg.m−3 with a lower limit of the detector's response estimated to be 210 fg.s−1; the potential for a point-of-care radiation exposure study exists.</div

    The peppermint breath test: A benchmarking protocol for breath sampling and analysis using GC-MS

    No full text
    © 2021 The Author(s). Published by IOP Publishing Ltd Exhaled breath contains hundreds of volatile organic compounds (VOCs) which offer the potential for diagnosing and monitoring a wide range of diseases. As the breath research field has grown, sampling and analytical practices have become highly varied between groups. Standardisation would allow meta-analyses of data from multiple studies and greater confidence in published results. Washout of VOCs from ingestion into the blood and subsequently breath could provide data for an initial assessment of inter-group performance. The Peppermint Initiative has been formed to address this task of standardisation. In the current study we aimed to generate initial benchmark values for thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) analysis of breath samples containing peppermint-derived VOCs using data from three independent European research groups. Initially, headspace analysis of peppermint oil capsules was performed to determine compounds of interest. Ten healthy participants were recruited by each three groups across Europe. The standard Peppermint protocol was followed. In brief, each participant provided a baseline breath sample prior to taking a peppermint capsule, with further samples collected at 60, 90, 165, 285 and 360 min following ingestion. Sampling and analytical protocols were different for each group, in line with their usual practice. Samples were analysed by TD-GC-MS and benchmarking values determined for the time taken for detected peppermint VOCs to return to baseline values. Sixteen compounds were identified in the capsule headspace, and all were confirmed in breath following ingestion of the peppermint capsules. Additionally, 2,3-dehydro-1,8-cineole was uniquely found in the breath samples, with a washout profile that suggested it was a product of metabolism of peppermint compounds. Five compounds (α-pinene, β-pinene, eucalyptol, menthol and menthone) were quantified by all three groups. Differences were observed between the groups, particularly for the recovery of menthone and menthol. The average time taken for VOCs to return to baseline was selected as the benchmark and were 377, 423, 533, 418 and 336 min for α-pinene, β-pinene, eucalyptol, menthone and menthol respectively. We have presented an initial set of easy-to-measure benchmarking values for assessing the performance of TD-GC-MS systems for the analysis of VOCs in breath. These values will be updated when more groups provide additional data